20 Most Recent Honda Eb 3500 Generator - Page 6 Questions & Answers

0helpful
1answer

Honda GX390 Generator not performing under load.

a GX390 Honda Motor but the used generator stator can be different cannot give more suggestions then measuring the circuitbreaker it can be broken the suggestion 60 mf capacitor can have trouble and electronic modul and bridge rectifier for some other dc connectors the coil diodes inside the stator. several options to go.
6/21/2017 5:53:12 PM • Honda Electrical... • Answered on Jun 21, 2017
0helpful
1answer

Honda EG 1500C Gen. No compression on pulling rope. Opened valve access cover. No movement on exhaust valve. Push rod from crankcase does not move Is this normal for easy start engines?

As far as I know this generator has not a manual activated valve opener. Therefor the exhaust valve may be stuck in the open position. Spray the valve stem/shaft at both side where it enters the casing with penetrating oil and leave for a while. (Hour or so). Try then to get the valve to move freely by moving the valve up and down. Use pliers but the jaws must be covered with a thick cloth as not to damage or scrape the valve stem. Ps. if the inlet valve moves but the outlet doesn't then the outlet is just stuck and need to be loosened.
6/9/2017 10:18:29 AM • Honda Electrical... • Answered on Jun 09, 2017
0helpful
1answer

13,500 a/c blows circuit and won't run off our honda 3000is generator

will it blow any circuit? if so, the a/c has an electric problem. will the a/c run when plugged into a service power supply?
6/5/2017 1:28:50 AM • Honda Electrical... • Answered on Jun 05, 2017
0helpful
1answer

Why can't i run my a/c with honda 3000is generator

This generator will run an a/c unit up to 13500 btus and is good for 2800 watts. This is a small generator, the nameplate rating numbers need to jive before overloading the energy supply.
6/5/2017 1:26:12 AM • Honda Electrical... • Answered on Jun 05, 2017
0helpful
1answer

I have a Honda 7000

If the generator is an auto stop/start type for standby use, it would seem those solenoids are the reason why fuel isn't getting through. It would be a fairly sensible method of stopping the engine remotely. An auto start/stop generator would need a battery for starting purposes, a battery that would presumably also provide current to energise those solenoids and allow fuel to flow. I suggest you refer to the instruction manual in the first instance...
5/27/2017 11:21:34 PM • Honda Electrical... • Answered on May 27, 2017
0helpful
1answer

Honda 3000 no current but yellow light on outlet circuit CAN i reset it

Was it ever electrically overloaded?
5/11/2017 1:52:37 AM • Honda Electrical... • Answered on May 11, 2017
0helpful
1answer

My Honda generator 3000 / inverter has a horrible gas leak what could it be

Try the tube that runs between the fuel tank and the carburetor. I have seen them crack since the tank is stationary and the engine is on rubber motor mounts. That line is in constant motion.
4/17/2017 7:17:23 PM • Honda Electrical... • Answered on Apr 17, 2017
0helpful
1answer

How to check the valve lash on honda eu3000is generator

You have to pull the rear (muffler end) cover, rear muffler protector (the metal vent), the rear handle, the lower end plate, and the fiber muffler protector so you have access to the head cover. Remove the head cover, disconnecting the breather tube as you do it. Turn the engine (using pull handle) to top dead center compression (both valves fully closed). Use feeler gauge to check the valve clearance between the rocker arm and the valve stem. Intake should be .15mm +/- .02mm (.006in +/- .001) Exhaust should be .20mm +/- .02mm (.008in +/- .001) Adjust as needed by loosening the rocker arm pivot locking nut and adjusting the rocker arm pivot. Tighten the locking nut once set. Put it all back together. :)
4/17/2017 7:07:32 PM • Honda Electrical... • Answered on Apr 17, 2017
0helpful
2answers

Gasoline smell in oil of Honda ex1000 generator I just bought. Your thoughts please. It was suppose to have been serviced but who knows. I am going to change the oil with a good grade 10w-30 HD.

Flooding carb perhaps or maybe lots of short duration runs that never allowed it to become thoroughly hot.
1/7/2017 11:32:56 PM • Honda Electrical... • Answered on Jan 07, 2017
0helpful
1answer

Honda eb6500 generator auto choke problem any way to convert to manual

Disconnect the auto choke assembly and hook up some sort of mechanism to manually open and/or close the choke. Spring load the choke so that the default position is fully open.
1/6/2017 2:55:21 AM • Honda Electrical... • Answered on Jan 06, 2017
0helpful
1answer
0helpful
1answer

Can i still get parts for honda generater eb1900?thanks

Harry, What parts do you need?
12/19/2016 10:28:19 AM • Honda Electrical... • Answered on Dec 19, 2016
Not finding what you are looking for?
Honda Eb 3500 Generator Logo

Popular Tags

21 questions posted

Ask a Question

Usually answered in minutes!

Top Honda Electrical Supplies Experts

vince

Level 3 Expert

2530 Answers

Paul Carew

Level 3 Expert

3808 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Honda Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Honda Electrical Supplies

  • Honda Electrical Supplies

Most Popular Question

honda eb3500x shuts off when auto

  • Electrical Supplies
Loading...