Leeson 3 Leeson Air Compressor Motor 208-230-460v 3ph - Page 9 Questions & Answers
How to replace nose o ring
Jerry,
I sent you a request because I don't know if iam getting all of the question and bugging me. But Nose 's I know. I just don't know what you have? did the oring squish out or something or is it just leaking air from the nose? so if you just want to replace it you will have to remove the bolts that hold the nose on should be hex most are I work at thomasindustrialsupplyinc.com so most of the things like bostitch have mm hex bolts although some have torx. But take off the guards and you should expose all the bolts. if its a bigger gun ( stick or coil) you'll have to remove the magazine. but no big deal. just keep all the parts segregated and don't lose anything will come off pretty smooth. the bolts will require a bit of effort depending on again the size of gun. I have found like the bigger ones take the 6mm hex while the finish take the 3mm hex and while the little ones are less tight sometimes strip the head. but the bigger guns may require a torch to the side to warm up and deactivate the threadlocker they put on the bolts. And depending on how the Nose is attached some have an oring that just sits in a groove while others have a ring that sits snuggly around it. If its one that sits in groove, add some light lease to it and that will be enough to hold it in place when you are assembling it .
If air is leaking its not the nose oring because the air shouldn't get that far down until its fired. so it could be other orings like around the spacer ring or the driver/ piston oring.
keep us posted
Craftmen 30 gal not working trips breaker
Neither the thermal protector, or the capacitor would cause a breaker to trip. You are looking for a dead short, something with power contacting the casing. Do it by elimination. Disconnect the motor and switch on. If the breaker doesn't flip. the motor is the issue. Or you can test all this stuff with a multimeter.
Ingersoll Rand SSR compressor shuts down loaded or
When it shuts down, press DISPLAY SELECT button once and use the up down arrows to see the code just before shutdown.
HIGH AIREND TEMP
HIGH AIR PRESSURE
LOW SUMP PRESSURE
PRESSURE OR TEMP SENSOR FAIL
CHECK MOTOR ROTATION
MOTOR OVERLOAD
FAN MOTOR OVERLOAD
STARTER FAULT
I am assuming this has a Intellisys controller.