20 Most Recent Fisher and Paykel Aquasmart wl80t65c - Page 7 Questions & Answers


It's best to use a film of petroleum jelly rather than any grease

Fisher and... | Answered on Feb 27, 2019


Check pump operation and cycle timer

Fisher and... | Answered on Feb 18, 2019


COULD BE A DEFECTIVE AIR DAMPER MOTOR , HAVE EVEN SEEN 1 THAT WAS WIRED WRONG AND HAD TO BE TOTALLY REPLACED BY MANUFACTURER , NOT YOUR BRAND THO

Fisher and... | Answered on Feb 17, 2019


I got this free Pdf manual from an online store for free and I don't think Ive visited a mechanic or fixya for help for more than 3-4 times out of the all the times I fixed the chipper in these 4 years

Fisher and... | Answered on Jan 30, 2019


Could be a cycle timer hang up

Fisher and... | Answered on Jan 26, 2019


not on this portion of the site go to the fridges in the home page eric

Fisher and... | Answered on Jan 20, 2019


Error code 136 motor stall. Can be caused by several things. 1. Faulty wiring or copper stator in motor. Check with ohm meter. You haven't said what model so I can't tell you what your ohms should be. 2. Faulty RPS (rotor position sender) That little circuit board on top of the stator. You need a special RPS test meter to check it. 3. Drum seizing up. Try spinning the steel bowl by hand, it should be very easy to rotate and no loud bearing noise. 4. Faulty main control board. Don't worry about the cracks in the stator. Nearly every machine I work on has cracks. It doesn't affect performance.

Fisher and... | Answered on Jan 10, 2019


possible board fault if rps has already been replaced,also check lid switch isnt faulty

Fisher and... | Answered on Jan 03, 2019


Google it perhaps they have answer there for you

Fisher and... | Answered on Dec 25, 2018


Your Error code is 130
130. (10000010) Phase 1 to 6 Single Rotor Position Sensor Error
The Motor Controller has found an error in the pattern received from the Rotor
Position Sensor. Likely causes of this fault are a bad connection on the harness
between the Rotor Position Sensor and the Motor Controller, or a faulty Rotor
Position Sensor.
Primary Source: Wiring.
Action:
1) Check for corrosion on the edge connector of the Rotor Position Sensor and
the Motor Controller module connector.
2) Check the contacts on the rotor positional sensor end of the hall harness to
see if any have been damaged. (Each set of contacts in the socket has two
wipers. If the distance between these wipers varies between different
contacts, replace the rotor positional sensor harness).
Secondary Source: Rotor Position Sensor.
Action:
Check the Rotor Position Sensor with an R.P.S. tester. Replace if faulty.
Tertiary Source: Motor Controller module.
Action:
Replace Motor Controller module.

Fisher and... | Answered on Nov 14, 2018


Check your lid switch. Take a PLASTIC Knife while lid is open and settings are on wash cycle...Stick it in the lid hole then see if washer turns on ..It might be cracked..That wound be the reason some time it works... Sometimes it don't...

Fisher and... | Answered on Nov 09, 2018

Not finding what you are looking for?
Fisher and Paykel Aquasmart wl80t65c Logo

121 questions posted

Ask a Question

Usually answered in minutes!

Top Fisher and Paykel Washing Machines Experts

Michael Thomas
Michael Thomas

Level 3 Expert

3053 Answers

peter gittos
peter gittos

Level 2 Expert

247 Answers

Marvin
Marvin

Level 3 Expert

85239 Answers

Are you a Fisher and Paykel Washing Machine Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Fisher and Paykel Washing Machines

  • Fisher and Paykel Washing Machines

Most Popular Question

fisher paykel top loading washing

  • Washing Machines
Loading...