20 Most Recent APC Power Saving BackUPS Pro 1300 - Page 4 Questions & Answers

0helpful
1answer

Apc relay welding

Hi and welcome to fixya sir please elaborate your problem i cant get it for what problem you are looking for a solution
10/1/2018 12:42:23 PM • APC Computers &... • Answered on Oct 01, 2018
0helpful
1answer

Hi i am looking for service manual for APC Matrix 5000 UPS. Is there is chance to get link for download it?

Use the phone numbers to contact the manufacturer in different countries in the world to request a service manual: https://excessups.com/manuals/Matrix-Manual.pdf https://excessups.com/manuals/Matrix-Manual.pdf
7/27/2018 11:51:50 AM • APC Computers &... • Answered on Jul 27, 2018
0helpful
1answer

APC UPS 1500 Battery charge icon is flashing between full and empty.

replace battery
5/29/2018 6:57:51 PM • APC Computers &... • Answered on May 29, 2018
0helpful
1answer

APC 1100 pro UPS - last two sets of batteries failed: hot and swollen failed within few years. Overcharging? Is there a fix? These batteries last in different applications for 5-7 years.

What you need to do is connect a Voltage Meter across the two terminals to monitor the VOLTAGE coming from the Charger portion and pushing power into the battery at a 'trickle' current(usually 20 to 1000mA). The battery is designed for 400-600 cycles of discharge, where the unit is on standby and runs till the battery is at 25% State-of-Charge. If the battery is drained lower than 25-30% SOC, then it may never recover, and fail prematurely. The idea of the UPS is to save the system files, and do an orderly shutdown. Not to continue with war-of-worlds until the lights come back on. (I am teasing about the first-person video game). So, see if the voltages going into the battery are about 13.5 volts to 13.75 , if they are higher, then the main unit needs to be re-calibrated for the battery size.
9/6/2017 11:06:04 PM • APC Computers &... • Answered on Sep 06, 2017
0helpful
1answer

Battery overcharge

It's most likely overcharging because you have bad batteries.
9/6/2017 10:26:35 PM • APC Computers &... • Answered on Sep 06, 2017
0answers
0helpful
1answer

Doesn't power on

Running a ups without batteries is not a got idea, the batteries are a critical part of the system and without them the ups will not function when the mains power is cut off.
however we can determine if the batteries may be an issue by removing them and checking the output voltage of each battery with a multimeter. I have personally found in the past anything less than 6v may or may not indicate an issue.
With all that said the ups should still turn on and try to boot and charge the batteries regardless if the batteries are dead flat or not. Assuming mains power is connected and the safety fuse is good then it seems most likely a fault in one of the control boards.

It's also worth mentioning that the fans will only start when either the inverter is running ie the mains supply is cut or like in my units the fans will remain on after the mains supply has been restored until the batteries have been recharged.
8/25/2017 2:18:11 AM • APC Computers &... • Answered on Aug 25, 2017
0helpful
1answer

I want to turn off the beeping sound on a apc ES550g battery backup system so it can be used for a sleep apnea machine. How/

I believe you will have to open it up and cut the speaker wire.
7/19/2017 1:28:11 AM • APC Computers &... • Answered on Jul 19, 2017
0helpful
1answer

APC 2200 RM XL AVR relay fault

i need help about APC 1500V 6 LEDs are Blinking simultaneously, did anyone tell me what part of hard need replace to remove this fault
3/18/2017 4:23:27 PM • APC Computers &... • Answered on Mar 18, 2017
0helpful
1answer

APC SMARTUPS 1000 3rd row last light is red. Why it is red. what will happen if it is red

Looks like you b=need to replace the battery inside.
2/11/2017 5:42:37 AM • APC Computers &... • Answered on Feb 11, 2017
0helpful
1answer

How do i silence apc 650 br while on battery operation?

You can disable the buzzer from chute APC monitoring software.
1/21/2017 10:16:21 PM • APC Computers &... • Answered on Jan 21, 2017
0helpful
1answer

Please any body give me apc rs 800 schematic diagram?

i have
1/21/2017 10:13:19 PM • APC Computers &... • Answered on Jan 21, 2017
0helpful
1answer

How do i mute the beeping sound on my apc 2.2kva smart ups

Audible cannot be turned off directly on the device. Install the software that came with the UPS, there is a setting in the software that allows audible warnings to be turned off.
1/21/2017 1:18:17 AM • APC Computers &... • Answered on Jan 21, 2017
0helpful
1answer
Not finding what you are looking for?
APC Power Saving BackUPS Pro 1300 Logo

2 questions posted

Ask a Question

Usually answered in minutes!

Top APC Computers & Internet Experts

Cindy Wells

Level 3 Expert

6688 Answers

Grand Canyon Tech
Grand Canyon Tech

Level 3 Expert

3867 Answers

Rob Hill
Rob Hill

Level 3 Expert

1480 Answers