20 Most Recent Frigidaire FAM157S1A Air Conditioner - Page 9 Questions & Answers

0answers
0helpful
1answer

On the FAH125p2T the display is reading in celsius instead of fahrenheit

Good Afternoon Friend, I understand you are trying to change the display from Celsius to Fahrenheit. To convert from one to the other and back, press and hold the " TEMP/TIMER" Up arrow and Down arrow buttons together for 3 seconds. I ask that you please follow up with a comment on the post, at your convenience, to advise if further troubleshooting is needed or if your appliances status has changed successfully. Hope this is helpful. -Best Regards- WP
6/19/2014 9:39:17 PM • Frigidaire... • Answered on Jun 19, 2014
0helpful
1answer

My fan wonT shut off

Good Morning Judy, I understand that the fan will not shut off on your Frigidaire air conditioning and heat, air conditioner, model# LRA18HMT2, even when you have turned your appliance completely off. I suggest resetting your appliance, by either unplugging it or shutting the power off at your home's circuit break, for 3-5 minutes. When power is restored, turn your air conditioner to any cycle and let it run for 5 minutes before turning it off. I ask that you please follow up with a comment on the post, at your convenience, to advise if further troubleshooting is needed or if your air conditioner status has changed successfully. Hope this is helpful. -Best Regards- WP
6/17/2014 12:51:40 PM • Frigidaire... • Answered on Jun 17, 2014
0helpful
1answer

I have a frigidaire fac105p1a that is spiting water out though the vents what do i do about that?

Good Morning Friend, I understand that you have water spitting out of the top vent on your Frigidaire air conditioner, model# FAC105P1A. I also see that it sounds like water is gurgling through the pipes and you want to know how to fix it. If your air conditioner is also leaking outside, this is normal during excessively humid days, due to it removing large quantities of moisture from a humid room. If it is also dripping inside, I suggest slightly tilting your air conditioner to the outside, to allow water drainage. I ask that you please follow up with a comment on the post, at your convenience, to advise if further troubleshooting is needed or if your air conditioner status has changed successfully. Hope this is helpful. -Best Regards- WP
6/17/2014 12:10:26 PM • Frigidaire... • Answered on Jun 17, 2014
0helpful
1answer

MYF AN WILL NOT SHUT OFF EVEN WHEN UNIT IS OFF

The ON/OFF switch is broke and stuck to the ON position. Does it cycle on and off for cooling with the thermostat? If yes, replace just the ON/OFF switch. If it is stuck on cooling 100 % of the time, replace the thermostat and the ON/OFF switch. The thermostat is a temperature controlled ON/OFF switch.
6/14/2014 11:31:52 PM • Frigidaire... • Answered on Jun 14, 2014
0helpful
1answer

Why is water in my ac unit power cord?

cold air condenses water vapor into fluid. If your power cord is below your air conditioner, you could move it, or create a barrier to prevent condensed vapor ("water") from flowing down the cord. If you need further help, reach me via phone at https://www.6ya.com/expert/john_77bb351c0c06b354
6/8/2014 12:02:16 AM • Frigidaire... • Answered on Jun 08, 2014
0helpful
1answer

Evereting work but fan not started

see if there is voltage to the fan. Check all connections, and boards.
6/1/2014 2:43:10 PM • Frigidaire... • Answered on Jun 01, 2014
0helpful
2answers

I have a window unit, model FAA067P7A2, and my dog chewed thru the power cord.

Buy a common 240 volt cord from a hardware store. Put cord ends(common hardware items) on to match existing.
5/27/2014 2:49:29 AM • Frigidaire... • Answered on May 27, 2014
0helpful
1answer

F6 error code on Frigidaire split unit ac, model FSC12CM6J/FSE12CM6J. Solution says to check fuse? Where is this located?

It seems like the indoor fan is not running. Quite a few split systems have a fuse on the indoor board. It will require stripping off the outer cover of the indoor unit and removal of the electronic box cover. The indoor board is in there. The fuse may be replaceable or it may be a type that is soldered on which makes it virtually non replaceable. ( A new indoor board will be required) Make sure all power is turned off or disconnected before you do anything. Another possibility is the fan motor start capacitor has failed. Try this first before stripping the unit. When the unit is turned on and the outdoor unit has started, give the indoor fan barrel a flick with your finger to start it spinning, if it keeps spinning and the error doesn't appear, it would indicate that the fan motor start capacitor has failed. The capacitors on indoor units are normally small black square boxes with 2 terminals on it. These capacitors are mounted inside or close to where the indoor electronic box is. Again, make sure all power is disconnected or turned off at the meter box before you do any disassembly.
4/9/2014 10:56:49 PM • Frigidaire... • Answered on Apr 09, 2014
0answers
0answers

LRA18HMT2 fan

Be the first to answer 2/3/2014 8:45:01 PM • Frigidaire... • Posted on Feb 03, 2014Be the first to answer
Not finding what you are looking for?
Frigidaire FAM157S1A Air Conditioner Logo

20 questions posted

Ask a Question

Usually answered in minutes!

Top Frigidaire Heating & Cooling Experts

Dan Webster
Dan Webster

Level 3 Expert

8221 Answers

Brad Brown

Level 3 Expert

18733 Answers

Steve Oakes
Steve Oakes

Level 2 Expert

234 Answers

Are you a Frigidaire Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Frigidaire Heating & Cooling

  • Frigidaire Heating & Cooling

Most Popular Question

as soon as plug into wall compressor

  • Heating & Cooling
Loading...