True 72 cu. ft. / 2039 liter Commercial Freezer GDM-72F - Page 2 Questions & Answers
My freezer is having uneven temps throughout. Some
I would check all seals and make sure there are no air leaks. From what you describe there may be several areas that allow warm air to enter and cold air to escape. If the humidity goes up in your location and the door is open a lot it can cause havoc with consistency.
I got a
These units have different options as to what the temp is suppose to be. I wonder if you didn't get the wrong thermostat.
Electrical shock everytime I touch the metal..
The problem is simple, the solutiion is difficult. There is a direct short somewhere in the system. If you remove the bottom front grill, you will see where the electricity comes into the unit.From that point forward a bare hot wire is touching the frame of the freezer. If you have a continuety tester, you may be able to find the problem with the power off. This is a time consuming situation and if you are not familiar with electrical circuits, it may be beyond what you are willing to tackle. You will have to isolate each circuit to determine which circuit has the short. One place to start is with the power cord itself. If you have continuety between the ground wire and either of the two hot wires, if 220 volt unit, the problem may be in the cord. If not continue to check the circuits from hot wire to ground. You may be able to disconnect the light circuit from the main power supply to see if the short is there. I have traced shorts for hours before finding a burned wire. Good luck.
Gdm 72 with remote temp goes from -10 to 20
Thanks for your question!
I'm sorry that you haven't received an answer yet.
The response rate on FixYa FREE questions is usually over 80%, but sometimes questions go un-answered when:
1. the question is unclear, incomplete, or poorly worded...
2. the question is mis-categorized - so the correct experts aren't viewing it...
3. the question requires an answer for something that cannot be explained online adequately...
4. specific training, tools, or equipment are required to avoid injury or death...
5. the Experts that are online simply don't have the resources to answer your question fully...
Please feel free to re-work your question if you feel one of these may be the reason.
Of course you are not required - but converting your question to a PAID one usually increases the reply rate as well.
Normal rates for FixYa are...
$ 9.99 answer for one question.
$12.99 Live Real-Time online chat or premium e-mail support.
$29.99 Live Real Time phone support
Sometimes FixYa will run specials for unlimited questions via monthly subscription or reduced rates for limited periods.
Consider the savings that can be had when an informed Expert can save you a $100 service call, or a $350 trip to the car dealership.
Your problem solved - guaranteed! Or your money back!!
If you don't want to pay - feel free to re-submit your question so it returns back to the top of the work queue if you still need help.
Thanks for using FixYa - a 4 THUMBS rating is appreciated for helping with your FREE question
Fans inside freezer will not turn - no cooling -
The fans are controlled with a clixon that has a cut in at 5 degrees, and cut out at 20 degrees. If the unit is running and the fans are not comng on then I would have to say you are out of freon. But your condensor fan could be running and the compressor NOT be running which could be a problem with your compressor. Find out if your compressor is running by taking an amp draw. If compressor IS running then you are low on freon. If the compressor is running and your evaporator coil is cold and your fans AREN'T coming on then your clixon is bad.
No door heat
The Mulluen heaters will be Built into the frame not in the door.
On freezer True T-23, the compressor works around 5 minutes and turn off for around 5-6 minutes and start again for another 5 minutes. I need help
That is what it is supposed to do. It is called cycling and switches off when the set temperature is reached. It is a commercial freezer, so if the door opened and closed often, that is normal?Commercial freezers and fridges have an item called a 'Clixon' that cuts power in the case of the compressor overheating. When was the last time the fins on the compressor coils were cleaned? Could also be a bad door seal letting cold air escape. When you close a freezer door on a unit like that, it should be really hard to open straight afterward due to the suction. Could be a faulty thermostat. Turn the temperature to the warmest setting and see if it still does it? If it does, you need a new thermostat.I just retired after 52 years in catering.https://www.katom.com/598-T23F.html?gclid=CjwKCAiArbv_BRA8EiwAYGs23PKtEzF60_OMVNpHXBlGjHQNdpp0pDZsu0G0lFLqVy2p4qIybG9n8xoCwEMQAvD_BwE..
Why is jenn air jcd2389ge hot around front freezer door frame?
The heat at the opening of refrigerator is usually a sign the condenser coils are dirty. Check the condenser coils for a restriction underneath the unit. Dirty condenser coils will cause poor air flow over the coils and compressor. Poor air flow will cause a lot of problems, including overheating the compressor, the refrigerant and the copper lines. This will destroy your sealed system. The coils need cleaning at least once a year, more often if you have pets.
I couldn’t determine if your unit has an “energy saver” setting. If so, turn it on. Not all refrigerators have energy saver. This is on units with emilion heaters in the wall around the door gaskets. The heaters are to eliminate condensation around the door. Turning ON energy saver turns OFF those heaters. You should notice a change quickly if it’s the heater causing the heat, that is, if you have that model.
Cleaning the coils will need a day or two to allow things to cool down before you notice a change in the heat around the door.
True 49f fans stopped running.
Compressor still runs. Fixes? Troubleshooting steps?
I am assuming you are relating to the evaporator fan(s) not running. If this is the case, some units have a 'Klixon" type thermostat in the evaporator so when the evaporator coil temp reaches a predetermined temperature, the fans come on. You may have a bad "Fan Delay" (Klixon) or the coil is not reaching the proper temp to activate it to turn on the fans. I would check the wiring diagram on the unit for this part to see if this unit has it in the system.