FREEZER /FRIDGE NOT COOLING: Optimum refrigerator temperature at or below40° F(4° C). The freezer temperature should be0° F(-18° C). Check temperatures periodically. Appliance thermometers are the best way of knowing these

Check ur cold control thermostat, ur thermistors in both fridge and freezer ( they should be checked for both ohms and for amount of current being put out as per ur model ), ur air flow vent from freezer to fridge.( to make sure it opens and closes without any restrictions) On thermistors check for A close circuit and amount of ohms not just an Ohm reading. As per ur model. Most should atleast show 1200 ohms. Also Check door seals for leakage.
Evaporator coils
Poor cooling is often the result of a heavy frost build-up on the evaporator coils. You can't see these coils without removing a panel on the inside of your freezer. A sure sign that there is a build-up is the presence of any frost or ice build-up on the inside walls, floor, or ceiling of the freezer. Such a frost build-up usually indicates a problem in the self-defrosting system or damaged door gaskets.
If one of the components in the self-defrosting system fails, the refrigerator continues to try to cool. Eventually, though, so much frost builds up on the evaporator coils that the circulating fan can't draw air over the coils. There may still be a small amount of cooling because the coils are icy, but with no air flow over the coils, cooling in the refrigerator compartment is quite limited.

FAN check to see if it is operating or restricted A fan that is not blowing or restricted will not circulate the cold air properly.

Often, the first thing that folks do when their refrigerator starts to feel warm is turn both controls on the coldest settings.This is exactly the WRONG thing to do.Turning the cold control to the coldest settingwillkeep the compressor running longer and make lots of cold air.

But turning the air door to the coldest settingclosesthe airway to the food section. Lots of cold air is made, but most of it stays in the freezer section, and the food section actually getswarmer.


Condenser
Self-defrosting refrigerators all have a set of coils and a cooling fan, usually under the refrigerator, that need to be cleaned regularly. If these coils get coated with dust, dirt or lint, the refrigerator may not cool properly. The coils may appear to be a thin, black, wide radiator-like device behind the lower kick-panel. To clean them, disconnect the refrigerator from the power source, use a refrigerator condenser brush and your vacuum cleaner to clean the coils of any lint, pet hair, etc. You may not be able to get to all of the condenser from the front, it may be necessary to clean the remainder of the condenser from the rear of the refrigerator.
May also need to check the defrost timer, u can get by and test manually by placing a small screw driver into the tiny slot or hole underneath the timer and turn slowly clockwise till u hear 1 click. this will engage ur defrost cycle in about 15 minutes u should be able to come back and feel the heat in freezer as it melts the ice providing ur terminator is not bad?
Another way to test it is with a multi meter. Remove timer it from fridge and you will see 4 prongs numbered 2,1,4,3 in that order. Place ur meter prong on prong 1 & 3 (if your fridge has a capacitor wired in series with the windings, then u check for micro fares rather than OHMS) If u cannot confirm this test, still try the next.
Take ur meter prong and connect to prong 1 & 4, it should read resistance or ohms ( closed) now remove prongs and place on prong 1 & 2, this should now read infinity or open (no ohms) now take a small screwdriver place it in the tiny hole or slot under the timer. Turn it clockwise slowly till u hear 1 click. Now ur 1& 2 should read closed ( showing ohms or resistance) now place meter prongs on 1 & 4 and you it should now show open ( or no resistance - no ohms) this is how u know ur timer is good, Remember when testing for ohms ADJUST meter to use a high ohms rating in the thousands as the resistance is very high in OHMS. And adjusting to low ohms rating may give a false reading or not show the proper resistance..

THE COMPRESSOR:
If you hear a clicking sound coming from the back of your refrigerator/freezer, then the problem is most likely the compressor, relay and or capacitor is overheating or not getting proper power and will not start.The compressor is the component on your refrigerator that allows your refrigerator to cool. If this component is not working properly your refrigerator will stop cooling. Most of the time the compressor is not the component that has failed.

To check ur compressor with multi meter:
Disconnect and remove the relay and capacitor from compressor, some located next to compressor in a casing.

You wills see 3 prongs coming out of compressor. 1 goes to ur srtart winding, 1 goes to ur run winding and the center goes to ur ground.

Place ur meter connector or prong on the start prong and the other on the ground (center prong) take note of the reading in OHMS for example 5 ohms.
Next place meter prong on run prong and the center ground prong agin. Take note of the reading in OHMS. Example 4 ohms

Next place meter prong on the start prong and the other on the run prong, now take note of the reading example 9 ohms. Now match the total of this ohms test with the total of ur two separate test. 9 ohms, if they match ur ok give or take 5 percent plus or minus. One more test to make to test of there is a short in compressor attach meter prong to ground prong and rub the other end of meter prong to metal ( scrape the metal clean of paint and test on metal surface not painted surface. If it shows continuity or ohms , u have a short in ur compressor. It should show infinity

TO REPLACE RELAY AND CAPACITOR WITH A HARDSTART KIT YOU CAN USE

A 3 in 1 start kit for compressors sizes 1/4 through 1/3 HP. And a 5 in 1 for higher H.P. (BE SURE TO MATCH WITH UR COMPRESSOR MODEL NUMBER AND TYPE) The kit includes relay, capacitor, and overload device, pre-wired. The kit will replace all 3 electrical components on capillary refrigeration systems. For newer systems with a run capacitor use proper kit. For smaller horsepower compressors useTJ90RCO810.

The wire set up is as follows the red wire goes to the right side of compressor prong, the white wire to the left side prong, the black wire to the center prong, and the 2 other black wires go to the power and the ground connection


Lastly you should also check ur THERMISTORS in the freezer and fridge section for continuity OHMS and for amount of OHMS current being put out. In most models around 13000 ( give or take 150 ohms) ohms is required.


Read more:

http://removeandreplace.com/2013/10/31/fix-refrigerator-freezer-wont-cool-freeze/#ixzz3WDEo5NDJ

REMEMBER GOD IS THE REASON FOR GOOD ADVICE"
Refrigerator Is Not Cooling What To Check And How To Fix

U-Line... | Answered on Dec 27, 2016


there must be a glazier business in the town to repair windows etc so go there with the length and width measurements and the thickness should be no less than 1/4 " or 6 mm to carry the shelf load
as the shop for a recommended glass thickness but I would not go under 6 mm and make sure that the edges are sander to get rid of sharp edges

U-Line... | Answered on Nov 18, 2015


Check circuit breaker/fuse in back of refrigerator usually located in the rear of the frige behind the panel where the electrical cord disappears.

U-Line... | Answered on Oct 15, 2014


Hi Liz,

I am wondering what motor you hear? I think you might hear the condenser fan motor if anything. The two things that I have seen fail on u-line products are condenser fan motors and/or cold controls. Not much to the unit at all. So I am going to assume you hear the fan motor in question, I would check voltage to the compressor and see why it not running first. Get back to me when you now more information and I can help you more. Good Luck

I’m happy to help further over the phone at https://www.6ya.com/expert/gere_bf68e6055dd61249

U-Line... | Answered on Jun 06, 2014


could be out of gas.

could also be a bad evaporator (inside ) fan.

is the back wall of the freezer icy and everything else warm

U-Line... | Answered on Jun 05, 2014


In order to prevent any confusion or potential damage, just empty the freezer, turn the power off, and leave open for a couple of hours.
To expedite the process, place a couple of large pans with boiling water inside the freezer and shut the doors.
Remember, unplug or turn the frig off in the process.

U-Line... | Answered on Jun 03, 2014


Make sure your thermostat isn't off. If not, my guess would be to first jump out the thermostat by completing the circuit without it, or just try replacing it. I would need more information including a model number to help you better.

U-Line... | Answered on May 29, 2014

Not finding what you are looking for?
Refrigerators Logo

34 questions posted

Ask a Question

Usually answered in minutes!

Top U-Line Refrigerators Experts

Marvin
Marvin

Level 3 Expert

85239 Answers

Kardoc

Level 3 Expert

6120 Answers

Dale Copeland
Dale Copeland