I have a 2020 cub cadet the motor goes up and down until it is under a load how to fix this?

called RPM surge carb is lean clean it. and no more lean. all lean burns cause that, the engine has RPM regulator that that fails lean, so the reg, hunts. my generator does that too, time to time;. I clean it. drain the carb at seasons end and avoid it next spring. gas engine not diesel cubs of old.
9/15/2022 11:00:19 AM • Cub Cadet Garden • Answered on Sep 15, 2022
0helpful
2answers

Cub Cadet 2166 cranks but wont turn over

check for spark---blown fuse--failed safety switch[s] --wire damage disconnection
9/7/2022 11:02:30 PM • Cub Cadet Garden • Answered on Sep 07, 2022
0helpful
1answer

Kohler 27hp Command engine on a Cub Cadet SLT1554 , Blows fuse at high rpm's only

THE FUSE BLOWS FOR A SHORT, AND PREVENT FIRE OR MORE DAMAGE, THERE. we find the short using a magic $25 tool called and AMMETER. Wrong fuse size used, told in manual and is wrong. amps. nobody can guess blind here, it can be a chaffed wire in the harness. or any wire or device on that fused line, (any repeat ANY) and I will not guess for you,. also battery voltage too high running 15vdc is max not 20v.
9/2/2022 1:04:20 PM • Cub Cadet Garden • Answered on Sep 02, 2022
0helpful
1answer
0helpful
4answers

I put Diesel in my cub cadet riding lawnmower, replaced carburetor cleaned the tank and it starts but after it warms up, it goes to running rough and puffing black smoke bogging down

Make sure the air cleaner is clean. May need to make an adjustment to the air fuel mixture when it is warmed up, Make sure the choke is opening all the way.
8/9/2022 5:41:22 PM • Cub Cadet Garden • Answered on Aug 09, 2022
0helpful
3answers

My cub cadet 1046 riding lawnmower won't stay running. I've replaced the fuel filter, both spark plugs, and sprayed carburetor ports with carburetor cleaner and it starts but won't stay running.

When you say "stay running", how long does it actually run for? Will it ALWAYS start and run, even if it dies, or will it sometimes not run at all and only turn over?
8/9/2022 2:37:08 PM • Cub Cadet Garden • Answered on Aug 09, 2022
0helpful
2answers

Rzt 50 cub cadet stops running after 5 seconds

fuel problems. start with fuel lines, filter. if that don't solve it take the carburetor off and clean it real good. maybe a carb. kit they are cheap.
8/9/2022 2:35:39 PM • Cub Cadet Garden • Answered on Aug 09, 2022
0helpful
2answers

Cub Cadet LT1050 just stopped moving

limited info generic answer theirs a few reasons ----drive belt fail---trans axle fail--linkage damage disconnect--transport lever active--rear wheel axle pin damaged or fell out
7/31/2022 11:58:13 PM • Cub Cadet Garden • Answered on Jul 31, 2022
0helpful
2answers

My cub cadet zero turn clicks when trying to start.

When I turn the key nothing happens. There are several elements that go into cranking (turning over) the engine.
  1. Battery
  2. Fuse
  3. Key Switch (and wiring)
  4. Starter Solenoid and wires
  5. Starter motor
Let's start with the battery. The quickest way to make your initial check of the entire starting system and particularly the battery is to get a jump. Yep, get some jumper cables and jump the mower off your car. Turn the key and try to start it in the normal fashion. If it starts cool! It is likely a bad battery.
  • Charge the battery for a few hours, on a charger.
  • Then perform a voltage measurement of the battery.
  • Switch a volt meter to DC Volts and clip it to the battery. It should read between 12-13 volts. If not the battery is suspect.
Now let's check the starting system while bypassing all the safety switches and wiring. How? You can perform this test simply by jumping the starter solenoid. Hold a wrench or fat screwdriver across the two large posts of the starter solenoid. This bypasses the key switch and all safety devices and directly drives the starter. Your starter will crank if the battery and starter are good, the wires and connections are good, and the engine is not locked up. Don't crank it for more that a couple seconds. You just want to verify the battery and the starter are both in good shape. (The engine will crank but not start during this test if the key is off, or if the safety switches or wiring are damaged, or if the safety switches are in the no start/run positions.) If the starter cranks try one more test. Run a small jumper wire from the positive post of the battery to the little terminal on the solenoid. You may have to take the small wire off the terminal, on the starter solenoid, in order to do this. When you apply this current from the battery to the terminal it should make the solenoid activate and the starter crank. This test bypasses the key switch and shows you the starter system is working. You could do this test first; if it works you do not need to do the basic jump test. If these tests cause the engine to crank, but it will not crank with the key, then you know you have a problem somewhere in your starter wiring, safety switch system, fuse, or in your Key Switch. Of course you did check the battery terminals for good connection, right? Most modern riding mowers have the following safety switches:
  • Seat switch
  • PTO switch
  • Reverse switch (RIS) and Reverse Relay (RIO)
  • Brake/Clutch switch
If you need detailed instruction for testing your wiring and safety system, I will need your complete machine info.
  • Make
  • Model
  • Year
  • Engine Model
  • Transmission Model
  • Deck Size.
On a John Deere (100 series) the starting current flows through the following items in this order:
  1. Battery to Fuse then to the Key Switch.
  2. With key switch in the start position, the current flows from the Key Switch to PTO.
  3. With PTO off, current flows from the PTO to Brake/Clutch
  4. With Brake/Clutch Pedal all the way down, the current flows to the starter solenoid.
  5. If the Starter Solenoid is in good shape, the solenoid connects the battery to the Starter and the engine cranks. Cranking does not mean running; it just means the engine turns over. Running is dependent on many other systems.
That list of components are all part of the cranking/starting system. They can prevent the Starter Motor from cranking when you turn the Key Switch. You can trace the voltage with a multi meter.Connect the black lead to ground and look for 12 volts on each successive step.If the voltage disappears at one particular step, there is your suspect. Electrical elements that are NOT part of the starting system: The RIO is the Reverse Implement Option. It is a switch that latches and stays latched under certain conditions. It is activated by the RIS. The RIS is the Reverse Implement Switch. It activates the RIO. These two separate components work to allow the blades to cut while you are backing up (without killing the engine). They have nothing to do with the starting system. The Seat and the RIO (the reverse latch not the button) switches are tied into the engine kill system.They provide a ground path for grounding the Coil. This same system controls the fuel shut off valve beneath the carburetor. The Seat and RIO can keep the engine from running but they will not prevent the Starter Motor from cranking. Therefore, if you turn the key and nothing happens, the problem has nothing to do with the Seat and Reverse switches. Note: With the Key in the RUN position, power flows from the Key Switch to the Hour Meter, then to the RIO latch relay (not the RIS button), then to the fuel shut off solenoid. If you do not hear the Fuel Shut off Solenoid clicking on and off when you turn the Key Switch from off to run, there may be a problem in this circuit; including a possible problem in the Hour Meter. Of course none of this affects the cranking circuit. Your engine will still crank, it just won't run.
7/30/2022 12:09:42 AM • Cub Cadet Garden • Answered on Jul 30, 2022
0helpful
2answers

I'm looking for A repair manual for an LTX 1050 CUB CADET MOWER

Manuals.com
7/22/2022 1:07:57 PM • Cub Cadet Garden • Answered on Jul 22, 2022
0helpful
1answer
0helpful
1answer

Cub Cadet XT-1 Shuts Off When I Stand Up

PTO switch is probably a 3 wire sensor, meaning it has an electronic module that communicates. it can not be bypassed, has to be replaced.
7/3/2022 5:40:45 AM • Cub Cadet Garden • Answered on Jul 03, 2022
0helpful
1answer
0helpful
2answers
0helpful
1answer

Drive belt i1050 cub cadet 2011yr what is size

The ground drive belt is part number 954-04134 (1/2 x 88.2 in.)(
6/13/2022 12:33:05 AM • Cub Cadet Garden • Answered on Jun 13, 2022
0helpful
1answer

Cub cadet m60is getting no power

check battery--fuse -connections ///with a meter check switch and safety switches
6/9/2022 11:32:53 PM • Cub Cadet Garden • Answered on Jun 09, 2022
0helpful
1answer

Why is my cub cadet heavy duty gt 2554 only mowing for maybe a minute then shutting off

"Oil Pressure Indicator (Refer to Figure 5)•This warning lamp indicates low engine oil pressure. If this indicator illuminates, stop the tractor immediately and check the engine oil level."

If oil level is in the safe range then likely the oil pressure sending unit is at fault.

If oil level is high and smells of gasoline, the carburetor float or needle valve has stuck and the carburetor will need serviced and the oil replaced.

It is normal for the fuel filter to appear empty while engine is running.
6/4/2022 2:39:22 AM • Cub Cadet Garden • Answered on Jun 04, 2022
0helpful
1answer

My Cub Cadet LT1045 PTO keeps turning off.

Wiring diagram is available no fee at;

https://www.ccpartsnmore.com/uploaded/files/cub-wire-schematics/cub-lt-tractor-wiring/LT%201045%20%282005%29.pdf

Use a volt meter or incandescent test lamp to verify the YLW/BLK PTO relay control circuit is active. Reference the lamp to battery positive and probe the YLW/BLK wire at the relay. The lamp must be lit for the relay to energize. If the lamp does not light then the relay is not being commanded to energize.

The relay has two YLW/BLK so you'll need to identify the one that goes to the relay control coil and not a relay contact.

Likely the relay is not being commanded ON so you'll need to follow the diagram and determine why.

Comment for further assistance.

5/30/2022 3:03:31 PM • Cub Cadet Garden • Answered on May 30, 2022
0helpful
1answer

I have cub cadet 1610 the tension pulley on deck drive belt the spring is unhook we're does it faster to

copy and paste https://www.ereplacementparts.com/cub-cadet-1610
4/24/2022 2:23:17 PM • Cub Cadet Garden • Answered on Apr 24, 2022
Not finding what you are looking for?
Cub Cadet RZT L42 42" 22HP Zero Turn Mower - 17ARCACS010 Logo

14 questions posted

Ask a Question

Usually answered in minutes!

Top Cub Cadet Garden Experts

john h

Level 3 Expert

29494 Answers

Steve Sweetleaf
Steve Sweetleaf

Level 3 Expert

1212 Answers

Daniel Blask
Daniel Blask

Level 2 Expert

232 Answers

Are you a Cub Cadet Garden Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Cub Cadet Garden

  • Cub Cadet Garden

Most Popular Question

fix

  • Garden
Loading...