20 Most Recent Rheem 3 Ton 14 Seer Package Heat Pump - RQPMA037JK000 Questions & Answers


Unit may have have iced up and defrost timer came on which is emergency heat check pressures and refrigerant

Rheem 3 Ton 14... | Answered on Dec 21, 2015


that reset is for the high pressure switch. this means your compressor is getting to hot which is then increasing the pressure and tripping the switch because the fan isn't running. usually if a capacitor is bad you can give the motor a "kick start " and the blade will then start turning. use a long stick or screwdriver to spin the blade but then you will know you need a cap. that switch is protecting your compressor, don't hold it down to keep it running.

If you need further help, reach me via phone at https://www.6ya.com/expert/thomas_092728000e6acb79

Rheem Heating &... | Answered on Oct 14, 2017


Likely a bad motor. If you have a meter and electricity confidence you need to verify that you have high and low voltage AT the motor. If both voltages present and still no motor you know it's bad. If no low voltage, possibly have a bad control board.

If you need further help, reach me via phone at https://www.6ya.com/expert/thomas_092728000e6acb79

Rheem Heating &... | Answered on Sep 16, 2017


no it is a straight a/c cooling only unit

Rheem Heating &... | Answered on Mar 10, 2016

Not finding what you are looking for?
Rheem 3 Ton 14 Seer Package Heat Pump - RQPMA037JK000 Logo

3 questions posted

Ask a Question

Usually answered in minutes!

Top Rheem Heating & Cooling Experts

Lawrence Oravetz

Level 3 Expert

10548 Answers

ray gallant

Level 3 Expert

71004 Answers

Marat Brikov

Level 3 Expert

515 Answers

Are you a Rheem Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Rheem Heating & Cooling

  • Rheem Heating & Cooling

Most Popular Question

emergency heat compressor not running

  • Heating & Cooling
Loading...