KitchenAid Architect II Superba EQ Series KUDE20FB - Answered Questions & Fixed issues
Fix f5 e 1
F1 - E0
EEPROM communication error
1. Disconnect power for at least 30 seconds.
2. Re-apply power and observe for at least one minute.
3. If code re-appears, replace control board (also called ERC or clock).
Note: Applies to all F1-E... codes except F1-E3.
F1 - E1
EEPROM checksum error
F1 - E2
UL A/D error(s)
F1 - E4
Model ID error
F1 - E5
Calibration shifted
F1 - E6
Latch signal mismatch error
F1 - E9
Stack overflow
F1 - E3
Wiring harness cavity size does not match previously stored value
The "Cavity Size Select" jumpers in the wiring harness indicate a cavity size different from that which the control was previously configured for. Check the jumpers in the harness to make sure they agree with the actual oven size.
6/5/2015 12:40:14 AM •
KitchenAid...
•
Answered
on Jun 05, 2015
•
588 views
KitchenAid Superba oven will not
the latch the hooks into the door is caught inside the slot where it locks into when in self clean,you have to move the latch,unplug it,look through the air vents or slots up above the door if you can get a screw driver in there try to move the latch or if you can get something down inside to move the latch,i used a plastic long wire tie to do this before,i slid the tie down around the metal hook part of the latch that locks into the door,and pulled it to the left and got the door to open,it got hung up in the hole and the door wouldn't open but what ever works you have to move the hook part of the latch to get the door open,you can try picking up on the door to see if you can get it open or you'll have to pull the oven out and take the top off to get at the latch,hope this helps
My kitchen aid double oven has an error code f6e6 contact am1
Possible Solutions
Reset power to the product:
There may be a problem with the Oven Appliance Manger Control or the associated wiring.
- Power unit down by turning off the circuit breaker(s) for one (1) minute.
- Power unit up by turning on the circuit breaker(s).
- Monitor the oven for one (1) minute to ensure the error code does not display again.
- Verify oven operation.
Still need help? Call or schedule service.
I have a Kitchenaid Imperial 17" Double KEDO
the is an external fan which draws all the moisture away,pull oven out and follows the two wires frm the and make sure both are connected and connected so it is alive when oven is on, if good the probaly a faulty fan