Top 20
KitchenAid Architect II Superba EQ Series KUDE20FB Questions & Answers
Fix f5 e 1
F1 - E0
EEPROM communication error
1. Disconnect power for at least 30 seconds.
2. Re-apply power and observe for at least one minute.
3. If code re-appears, replace control board (also called ERC or clock).
Note: Applies to all F1-E... codes except F1-E3.
F1 - E1
EEPROM checksum error
F1 - E2
UL A/D error(s)
F1 - E4
Model ID error
F1 - E5
Calibration shifted
F1 - E6
Latch signal mismatch error
F1 - E9
Stack overflow
F1 - E3
Wiring harness cavity size does not match previously stored value
The "Cavity Size Select" jumpers in the wiring harness indicate a cavity size different from that which the control was previously configured for. Check the jumpers in the harness to make sure they agree with the actual oven size.
6/5/2015 12:24:00 AM •
KitchenAid...
•
591 views • 0 helpful votes
My kitchen aid double oven has an error code f6e6 contact am1
Possible Solutions
Reset power to the product:
There may be a problem with the Oven Appliance Manger Control or the associated wiring.
- Power unit down by turning off the circuit breaker(s) for one (1) minute.
- Power unit up by turning on the circuit breaker(s).
- Monitor the oven for one (1) minute to ensure the error code does not display again.
- Verify oven operation.
Still need help? Call or schedule service.
Not finding what you are looking for?