Check to make sure that there is enough water in the pool and that the weir door in the skimmer box isn't jammed in the upright position

Hayward Pool &... | Answered on Jul 16, 2019 | 138 views


As JerryFin mentioned, there are cracks in the solder on the circuit board edge connector that cause the unit to stop heating randomly. All you need to do is pull the board and re-flow the solder.
cracks in solder-1-u4sqn5xicldc4uqfsahcb5tp-4-0.jpg

edge connector-u4sqn5xicldc4uqfsahcb5tp-4-2.jpg

cracks in solder-1-u4sqn5xicldc4uqfsahcb5tp-4-0.jpg

Hayward Pool &... | Answered on Jul 14, 2019 | 309 views


The pump is not communicating with the control system. Check the comm wire and make sure it is intact and not chewed/worn/damaged.

Hayward Pool &... | Answered on Jul 06, 2019 | 158 views


The first hint i would suggest is only turn selector in clockwise direction always.
not to insult but you must have pump off during selectiong.
Now, The ball valve sounds like it is out of alignment.
because of wear, from going back and forth not rotational.
you can check for alignment by checking to see if you have any flow coming out return nozzle into pool. There should be none during backwash.
pressing the handle down unlocks rotation, so if you are handy remove selector from top of filter, then check motion as you move selector. I have used o ring lubricant to lube parts in selector.
BEFORE DISSEMBLING NOTE POSITIONS OF BALL Inspect how the push down to rotate function.
If lubing is no help creating smooth rotation you may need to replace assembly.

Hayward Pool &... | Answered on Jul 06, 2019 | 127 views


Contact the manufacturer or a dealer

Hayward Pool &... | Answered on Jun 09, 2019 | 136 views


CE error code on Hayward pool heater. CE= Communication Error between Control Module. and Display Interface Assembly

Hayward Pool &... | Answered on May 21, 2019 | 106 views


It means it time for a new one

Hayward Pool &... | Answered on Apr 12, 2019 | 380 views


There is air trapped in the unit. Hold it under water and rotate it over and over

Hayward Pool &... | Answered on Feb 26, 2019 | 165 views


even when the unit is off (but powered up), there should be information on the display board. if not, the heater will not work. all the boards 'communicate' with each other

Hayward Pool &... | Answered on Feb 12, 2019 | 203 views


check the roll out switch!

Hayward Pool &... | Answered on Jun 26, 2018 | 406 views


have it checked out by a gas professional
the white smoke could have been moisture in the insulation but the gas supply side should be professionally checked

Hayward Pool &... | Answered on May 29, 2018 | 455 views


possible start run capacitor failure
hard to turn while on indicates bearing failure allowing the armature to touch the field poles

Hayward Pool &... | Answered on Jun 23, 2018 | 254 views


Sounds like somebody did not have the filter properly seated when they tightened the top if it is that type.

Hayward Pool &... | Answered on Oct 18, 2017 | 171 views

Not finding what you are looking for?
Hayward 1 12 Hp Super Swimming Pool Pump Sp2610x15 Logo

57 questions posted

Ask a Question

Usually answered in minutes!

Top Hayward Pool & Spa Experts

john h

Level 3 Expert

23515 Answers

Marvin
Marvin

Level 3 Expert

85239 Answers

Paul Carew

Level 3 Expert

3530 Answers

Are you a Hayward Pool and Spa Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...