its trying to start check voltage to fan if ok bad fan motor if no check safety circuit

Hayward Pool &... | Answered on Dec 19, 2020 | 16 views


Could the Error code be HS? That is high temperature limit. Perhaps you' don't have enough flow, allowing the heater to heat the water to a temperature higher, than the thermostat setting. Make sure your bypass valve is closed, allowing full flow through the heater. Check your filter pressure differential , and skimmer baskets.
You didn't give your model number, and there are many models. You can go the Hayward website below and select your exact model number and download the manual. The manual will explain each error code.
http://www.haywardnet.com/inground/products/manuals.cfm

Hayward Pool &... | Answered on Jun 07, 2020 | 12,510 views


Are you sure it has a centrifugal switch?
Capacitor start/ capacitor run have been the standard for a good number of years.

Hayward Pool &... | Answered on Oct 26, 2019 | 305 views


Hayward's website has manuals for all their products.

Hayward Pool &... | Answered on Oct 26, 2019 | 123 views


The 24v is called the secondary and sometimes called the out-put. Make sure you have 240v on the primary, sometimes referred to as the in-put. If you have primary voltage then you should have secondary voltage, if not then replace transformer. Make sure the secondary, 24v control fuse is the correct size and present. If the secondary is shorting together or to ground somewhere, it will cause damage to the transformer.

Hayward Pool &... | Answered on Aug 18, 2019 | 131 views


Call a qualified electrician. More information would be needed to accurately trouble shoot your issue. Do you have automation connected to your heater? Is the heater trying to fire when the pump is off or is it ONLY the fan?
Try disconnecting your Water Pressure switch on the heater and see if the issue stops. With WP switch disconnected the heater should not work and the fan should stay off. Replace WP switch and see what happens.
Call a QUALIFIED electrician.

Hayward Pool &... | Answered on Aug 12, 2019 | 131 views


Check for proper supply voltage and that the impeller moves freely. If these are good then likely a bad capacitor.

Hayward Pool &... | Answered on Jul 30, 2019 | 132 views


the prologic control unit will not offer programming for what you seek. the most detailed timers will offer weekday or weekend for each pump speed. you may want to get a remote system so you can control functions from your smartphone

Hayward Pool &... | Answered on Jul 26, 2019 | 130 views


try filling your hose by holding it in front of the return jet. once filled, hook the hose up as normal

Hayward Pool &... | Answered on Jul 26, 2019 | 161 views


this is a common issue. there is a componant on the circuit board called a voltage limiter. when there are power surges (by hydro company or by using a timer), this capacitor takes the surge to protect the circuit board. in your case, the limiter has blown.
you can either replace the circuit board or find someone to remove the limiter and solder in a new one. (its the round black disc to the right of the front display toward the top) in most cases, you will see a hairline crack in the casing or it may have exploded completely. i usually tap it with a screw driver to show customers the damage. FYI: i usually replace about 50 a year and never had one fail

Hayward Pool &... | Answered on Jul 26, 2019 | 135 views


the rinse setting only cleans out the dirty water in freeboard and pushes sand to pack it. just about impossible for it to not work. if there is water coming out the discharge, you are golden.

Hayward Pool &... | Answered on Jul 26, 2019 | 128 views


there is a relay on the back of the main circuit board that has separated from the circuit. you can resolder this relay quite easily by removing the board.
DANGER: be sure to cut the power to the control box at the main breaker. turning off the breakers in the hayward box will NOT eliminate the power

Hayward Pool &... | Answered on Jul 26, 2019 | 172 views


i find the aqua rite systems to be very helpful in diagnosing problems. if you can describe the problem you are having, i may be able to help

Hayward Pool &... | Answered on Jul 26, 2019 | 117 views


As far as I know, refrigerant is not used in the heating of pools and spas. Sounds like it is just a connection leak and can be fixed by redoing the joint connection.

Hayward Pool &... | Answered on Jul 25, 2019 | 115 views

Not finding what you are looking for?
Hayward 1 12 Hp Super Swimming Pool Pump Sp2610x15 Logo

57 questions posted

Ask a Question

Usually answered in minutes!

Top Hayward Pool & Spa Experts

john h

Level 3 Expert

23515 Answers

Marvin
Marvin

Level 3 Expert

85239 Answers

Paul Carew

Level 3 Expert

3530 Answers

Are you a Hayward Pool and Spa Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...