The title description is a Hayward Super II 1.5 HP but the part number you gave is for a StaRite MaxiGlas pump. Either way the motor needs to be replaced.
The best way to find out what you need is to look at the part number on your impeller. With that information whoever you buy the motor from will be able to get you the correct pump and seals..

Hayward... | Answered on Nov 03, 2013


There is no cheap fix for a burned up motor...you'll need to replace it. You can replace just the motor for about half the cost of a whole new unit. When you replace the motor you should replace the pump seal as well. Your motor number should be UST1152 for the 1.5 HP and the seal number a 201.

John

Hayward... | Answered on Jun 27, 2011


its trying to start check voltage to fan if ok bad fan motor if no check safety circuit

Hayward Pool &... | Answered on Dec 19, 2020


Could the Error code be HS? That is high temperature limit. Perhaps you' don't have enough flow, allowing the heater to heat the water to a temperature higher, than the thermostat setting. Make sure your bypass valve is closed, allowing full flow through the heater. Check your filter pressure differential , and skimmer baskets.
You didn't give your model number, and there are many models. You can go the Hayward website below and select your exact model number and download the manual. The manual will explain each error code.
http://www.haywardnet.com/inground/products/manuals.cfm

Hayward Pool &... | Answered on Jun 07, 2020


Are you sure it has a centrifugal switch?
Capacitor start/ capacitor run have been the standard for a good number of years.

Hayward Pool &... | Answered on Oct 26, 2019


Hayward's website has manuals for all their products.

Hayward Pool &... | Answered on Oct 26, 2019


The 24v is called the secondary and sometimes called the out-put. Make sure you have 240v on the primary, sometimes referred to as the in-put. If you have primary voltage then you should have secondary voltage, if not then replace transformer. Make sure the secondary, 24v control fuse is the correct size and present. If the secondary is shorting together or to ground somewhere, it will cause damage to the transformer.

Hayward Pool &... | Answered on Aug 18, 2019


Call a qualified electrician. More information would be needed to accurately trouble shoot your issue. Do you have automation connected to your heater? Is the heater trying to fire when the pump is off or is it ONLY the fan?
Try disconnecting your Water Pressure switch on the heater and see if the issue stops. With WP switch disconnected the heater should not work and the fan should stay off. Replace WP switch and see what happens.
Call a QUALIFIED electrician.

Hayward Pool &... | Answered on Aug 12, 2019


Check for proper supply voltage and that the impeller moves freely. If these are good then likely a bad capacitor.

Hayward Pool &... | Answered on Jul 30, 2019


the prologic control unit will not offer programming for what you seek. the most detailed timers will offer weekday or weekend for each pump speed. you may want to get a remote system so you can control functions from your smartphone

Hayward Pool &... | Answered on Jul 26, 2019


try filling your hose by holding it in front of the return jet. once filled, hook the hose up as normal

Hayward Pool &... | Answered on Jul 26, 2019

Not finding what you are looking for?
Hayward SP3015EEAZ Super II Pump 15Horse Power Logo

2 questions posted

Ask a Question

Usually answered in minutes!

Top Hayward Pool & Spa Experts

john h

Level 3 Expert

23515 Answers

Marvin
Marvin

Level 3 Expert

85239 Answers

Paul Carew

Level 3 Expert

3530 Answers

Are you a Hayward Pool and Spa Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Hayward Pool & Spa

  • Hayward Pool & Spa

Most Popular Question

pool motor tripped breaker when reset

  • Pool & Spa
Loading...