Clearing memory on Pentair vs pool pump

To reset the pump; You will need to hold down all four speed buttons for a few seconds, then release them, then push select twice, you will see "0" highlighted, push the arrow up button to "1" then press enter, then shut the power down to the pump for about one minute, then power it back up and your pump should be back to factory settings.
5/14/2017 12:05:53 PM • Pentair Pool &... • Answered on May 14, 2017
0helpful
1answer

My pentair 52018 controller also turns on a firebowl...it ignites fine but shuts off after 10 seconds...we just replaced it because it was doing something similar with the spa heat...

The Pentair should not be controlling the fire bowl ignition, only the power to the fire bowl. The ignition will be controlled by a separate system designed for the bowl. The spa heater is controled by the pentair via a water temp sensor and the heater has it own onboard ignition system. Have someone qualified look at the fire bowl, sounds like a flame sensing issue.
5/14/2017 12:01:31 PM • Pentair Pool &... • Answered on May 14, 2017
0helpful
1answer

No power to pentair mastertemp 400. Power going into tranformer, and power to ignition control module. Replaced display motherboard. Still not lighting up. Replace tranformer?

Check the control fuse on the power interface board and also the fuse inside the silver box. The control loop will prevent the heater from coming on if it is open.
5/14/2017 11:54:37 AM • Pentair Pool &... • Answered on May 14, 2017
0helpful
1answer

I have a pentair easy touch and the waterfall is turning on will all programs. Have reset all schedules and still turns on . can tfigure out where it is reading to turn on waterfall

It may be more of a mechanical problem than programing. There is typically a switch on the motorized valve itself. It can sometimes be hard to see or find. The switch is a three position switch. In the center is for remote use while switching it up or down will allow you to bypass the remote to open or close the valve. My guess is it could possibly in the open position so no matter what you tell it to do in the programming it is always open.
4/29/2017 3:50:08 PM • Pentair Pool &... • Answered on Apr 29, 2017
0helpful
1answer

Have a Pentair high performance pump. 350097 is the number on outside of pump. What gasket do I need? Pump is leaking and it will not prime. Thanks

scroll down to pentair,https://www.poolpartsonline.com/p-425-filter-repair-kits.aspx
4/21/2017 12:39:36 AM • Pentair Pool &... • Answered on Apr 21, 2017
0helpful
1answer

I have a Pentair 7 186237-01 pool pump. the capacitor was replaced 1 year ago. it is acting like the capacitor has failed again. did they put on the wrong capacitor?

no capacitors either work or they don't work being electronic and subject to surges and spikes they can last many years or just months there are various qualities of capacitors but even that is no guarantee of long life you can check if the capacitor is correct by getting oll of the details off the plate on the motor( volts, current , rpms , hertz-phase , cycles etc and with that information take the failed capacitor to an electric motor repair shop and they will know if it was correct or not the requirements are correct voltage and mica/peka farads required to start/run the motor there is a permissible range but outside that range , the capacitor is wrong
4/17/2017 3:34:21 AM • Pentair Pool &... • Answered on Apr 17, 2017
0helpful
1answer

I have a 1.5 Pentair pool pump and it has blown 3 capacitors what could be the problem

Make sure your voltage is correct at motor connections. Also make sure the pump is not bound up. The voltage needs to be checked at the motor NOT the breaker.
4/2/2017 2:10:34 PM • Pentair Pool &... • Answered on Apr 02, 2017
0helpful
1answer

Pentair mastertemp 400 no pwer to display. Replaced display. Transformer problem?

Check your control fuse. If the control fuse is bad replace it w/2 amp fuse. The old board could have blown the fuse. If the fuse blows again DO NOT increase the fuse size. Instead find the short in the control circuit.
4/2/2017 2:05:17 PM • Pentair Pool &... • Answered on Apr 02, 2017
0helpful
1answer

The off button on my Pentair MasterTemp 400 pool heater does not shut if off. All the other button controls work. What is wrong?

You need to replace the "membrane pad". The pad is separate from the control board. Sort of like a keyboard on a computer.
4/2/2017 2:02:07 PM • Pentair Pool &... • Answered on Apr 02, 2017
0helpful
1answer

Pentair intellichlor salt cell keep blowing fuses

The cell will blow the fuse if it is bad. If it is a new unit call Pentair for warranty.
4/2/2017 2:00:06 PM • Pentair Pool &... • Answered on Apr 02, 2017
0helpful
1answer

I have an Pentair Easy Touch 8. I push the Filter button on the outdoor panel. The green light is on but my filter does not turn or start on. I ran the Self Test and no error code. Any idea's?

this could be a number of issues....

Pump motor could be bad, capacitor could be bad, relay could be bad, or a circuit board issue.

Check the breaker for the filter pump, turn it off and back on.

Press the reset. It tim on the outdoor control panel and wait for a few minutes as it reconfigures.
Then try to turn it on again.
If that doesn't work
If you know how then test the leads at the motor once you have pressed the filter button.
Otherwise you probably need a professional to check on it.

1/2/2017 7:12:19 PM • Pentair Pool &... • Answered on Jan 02, 2017
0helpful
1answer

Pentair mastertemp 250 heater showing 126

I don't think that 126 is an error code but more likely it's showing that as the temperature.

A new temperature probe will probably be the fix.
10/27/2016 5:33:21 AM • Pentair Pool &... • Answered on Oct 27, 2016
0helpful
1answer

My passcode for my pentair intelliflo pump. My P/N is 160316 Serial number is 0194093120048V

There is no way to retrieve a passcode, it is a personnel feature chosen by you and not something you can just bypass, if you could what use would the passcode be.
10/19/2016 7:19:47 PM • Pentair Pool &... • Answered on Oct 19, 2016
0helpful
1answer

My pentair whisperflo pool pump sparked and smoked ,I noticed water in the electrical on back of pump..

take it to a motor repair shop but with sparks and smoke it is a fair bet that it is burnt out
8/9/2016 8:49:26 PM • Pentair Pool &... • Answered on Aug 09, 2016
Not finding what you are looking for?
Pentair MasterTemp high Performance Gas Heater 200 BTU  () Logo

2 questions posted

Ask a Question

Usually answered in minutes!

Top Pentair Pool & Spa Experts

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

Brad Brown

Level 3 Expert

19187 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Are you a Pentair Pool and Spa Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Pentair Pool & Spa

  • Pentair Pool & Spa

Most Popular Question

mater temp only

  • Pool & Spa
Loading...