Briggs & Stratton Briggs and Stratton 30335 4000 Watt Briggs Stratton Pro Generator - Page 2 Questions & Answers
Generator wont srart
tank filter carburetor , sprayer , gaskets (sometimes) OIL-LEVEL to low or (it can happens but not often ) defect oil-control if oil level is good temporarily pull the oil monitoring loose bougie BCPR6ET does sometimes good equivalent services.
If the ignition module is defect no sparking and you are order a new one you must know the serialnumber of the engine type to get the right one because of modifications by later build of the same models van later construction year. or there is a valve problem
But that is rare . to high overcurrent for start start the generator without connected tools .
12/2/2015 8:33:10 PM •
Briggs &...
•
Answered
on Dec 02, 2015
How to test portable generator stator for short in windings
You will need what the factory resistances valuea re supposed to be, cold. Then use a high quality ohm meter with 3 decimal places, disconenct all wires off the stator. Check each wire with a meter to the ground frame, if there is any value, stator is shorted. Then check between stator wires ie L1 L2 and compare resistance value with factory values.
3/1/2015 10:28:05 PM •
Briggs &...
•
Answered
on Mar 01, 2015
How to test for a shorted generator stator
Sounds like you have a dead short. Check the outlets for any debris, metal or copper. Check the backside if the outlet for anything grounding onto the unit. The breaker is tripping to protect the outlet and anything plugged into it. The fire shooting out of the outlet is an arc flash caused by the dead short. You can also try disconnecting and replacing the outlet . If the problem persists, disconnect the starter and try to bench test it with a multimeter. I hope this helps. Good luck.
10/2/2014 9:27:06 PM •
Briggs &...
•
Answered
on Oct 02, 2014