Only runs with choke

There is an air leak in the seals somewhere between the carb and the intake manifold. You are getting too much air! ALL of those seals need to be changed, As the paper seals age they develop small cracks that kill the vacuum made by the engine to pull in the gas/air mixture!
12/23/2012 7:26:44 PM • Champion... • 969 views • 1 helpful votes
1helpful
1answer

Low current. Will hardly drive a sander or

I found this at http://www.championpowerequipment.com/tech-bulletins/AVR Voltage Adjustment

This bulletin covers the following Champion Power Equipment models:

C46535 C41150 C41365

C46540 C41155 C75520E

C49055 C41255 C71350E

Note: Read instructions completely before performing service.

1. On the end of the generator locate the round yellow cover held on by two 7mm bolts.

Remove the two bolts and the yellow cover will come right off.

2. At approximately 7 o'clock you'll see a kidney shaped electrical component called the AVR,

which is held on by two 7mm bolts. Remove the two bolts but do not disconnect the wiring

and turn the AVR over so you can see the backside. You should see a round part coming off

the AVR, this is the capacitor. You should also see a small rectangular box with a jewelers

screw, this is your voltage adjustment screw.

3. With a flat head screw driver turn the jewelers screw counter clockwise and this will lower

the voltage. As the screw is turned back watch the volt meter to see adjustment, the

generator must be running to do this.

4. Adjust the screw until the meter reads 250 volts. On model C46540 when the toggle switch

is turned to the 120 side the volt meter should read around 130 volts. Optimum voltage is

121.8 volts.

5. If voltage does not decrease or does not hold a steady output please contact Champion at

877-338-0999 for a new AVR.

If you have any questions, please contact Champion Power Equipment:

Champion Power Equipment, Inc.

10006 Santa Fe Springs Rd.

Santa Fe Springs, CA 90670

Phone: 1-877-338-0999 Email: [email protected]

7/2/2011 5:08:44 PM • Champion... • 710 views • 1 helpful votes
1helpful
1answer

My Champion 6.5HP Generator has

They have a website at http://www.championpowerequipment.com. Click "support" and they tell you "If you need to order a part please call our tech support line. Our professionally trained technicians will be able to assist with placing orders. Orders ship within 1 business day - orders received before 2:00 PM (PST) will be shipped same day." The number is 1-877-338-0999. They also have many service bulletins thee thay will help solve many problems.
4/23/2011 1:41:05 AM • Champion... • 1,584 views • 1 helpful votes
0helpful
1answer

I have a GG350 Powerlift

Yes you should indeed find out WHY the breaker is tripped in the first place? and why it will not reset.
The ONLY thing that will cause a breaker to trip,and not be able to be reset, is a short circuit, across the "line" Phase and Neutral, usually that or a Short to Earth? This MUST be checked out first. One must NEVER EVER simply replace or indeed reset a breaker without first finding out exactly WHY it occurred in the first place. Breakers seldom if ever spontaneously break down.
This may happen if there is a fault in the circuity in the Gen.
To be able to really do anything one must obtain a service manual first.
7/4/2011 9:41:04 PM • Champion... • 65 views • 0 helpful votes
1helpful
1answer

The coil rope broke I would like to know how i can

If I understand correctly, you have a pull-start generator.

The rope to the pull-start broke.

This happened to us out on the job one day.

Our equipment might be different than yours. Our pull-start assembly is held with 4 bolts. Simply remover those bolts and lift off the cover ... carefully. The rope is attached to something I will call a pulley. The rope wraps around the pulley several times.

Do not lift out the pulley that the rope attaches to >> or the spring that re-winds the rope will come un-sprung (at least it did on our machine). If the spring comes unwound, then you got another job, and have to put the spring back also. Your machine might be different.

Keep pulley in place. Remove rope. Get another rope with same diameter and length and put it in.
10/18/2010 7:59:00 PM • Champion... • 689 views • 1 helpful votes
0helpful
1answer

I have a champion generator model 41552 and when I plug the power cord for 240 volt it trips to breaker on machine

If your voltmeter is registering the 240v prior putting in the twist-lock plug then your have a crossed wire plug or there is a problem with the load. If not reading the correct voltage then you have problem with the generator's alternator. Example bad regulator or a shorted main winding.
11/23/2014 11:26:05 AM • Champion... • 192 views • 0 helpful votes
0helpful
1answer

How do I fix my generator when I get gas in my oil?

This comes from gas getting from the carb when the engine is stopped. The carb will need a good cleaning. Kawasaki has vent tubes just to avoid this when air venting gets plugged. Just saying. ..
10/29/2014 2:28:53 AM • Champion... • 146 views • 0 helpful votes
0helpful
1answer

1500 not start

Did you leave any gas in it as it was being stored. If so then your probably looking at dirt or varnish in the carb. It this is the case you will need to taske the carb apart and spray the inside with some carb cleaner then make sure to wipe it all out. Next time you store your generator make sure that you compleatly drain all of the fuel. If not then be sure to add some gas stabilizer. Good luck, Marty
7/15/2014 10:51:48 PM • Champion... • 40 views • 0 helpful votes
0helpful
1answer

Where do I find a repair manual for a champion 196 cc motor

www.championpowerequipment.com
5/1/2012 9:32:55 PM • Champion... • 154 views • 0 helpful votes
0helpful
1answer

Wiring 3 lights 3 separate switches

Consult a qualified electrician.
3/22/2024 7:54:02 PM • Electrical... • 16 views • 0 helpful votes
0helpful
1answer

GE outdoor 200A fusible disconnect can not stay on position, how to fix this issue

It has a cantilever snap action. Either the spring has detached, broken, disabled or unit is otherwise damaged. Heat, water, rodent, etc damage. Replacing the unit is most likely your only option.
2/9/2024 7:43:00 AM • Electrical... • 27 views • 0 helpful votes
0helpful
1answer

Powerback 10 horsepower 5000 watt generator. I am having hard time starting it. I put a new spark plug in it still a hard time starting. Can you help please?

Question edited for clarity. Engines only need 3 things to run Fuel (is it fresh, carb clean, jets clear) Compression (test with compression gauge) A spark at the right time (remove plug, ground it, check for spark)

10 Common Reasons Your Generator Won't Start

WEN Products https://wenproducts.com > blogs > resource-center > h... Jun 3, 2022 - 1) It's low on oil · 2) It's out of gas · 3) The choke lever is in the wrong position · 4) The fuel valve is closed or clogged · 5) The carburetor ...

I have a powerback 5000 watt with a 10 hp, tecumseh motor

JustAnswer https://www.justanswer.com > small-engine > 8nqnk-p... Sep 13, 2014 - Hi my name is ***** ***** welcome to just answer. . Here is a link to show you the options at adding electric start. There are two ways you can ... 1 answer · Top answer: If your happy with my service please don't forget to rate my service. Thanks John

10 Reasons Why Your Generator Won't Start - Blog

professionalservicestoday.com https://www.professionalservicestoday.com > generato... Aug 17, 2021 - Top 10 reasons your emergency home generator won't start · 1. Fuel Tank Is Low. Your fuel should be the first thing you check. · 2. Low Oil Levels ... ..
1/11/2024 5:10:59 AM • Electrical... • 37 views • 0 helpful votes
0helpful
1answer

What is the valve clearance on a Duramax 13000 generator?

Most Duromax OHV engines are as follows with engine cold (ambient air temperature).0.006 in. intake 0.008 in. exhaust
1/16/2024 9:15:20 PM • Electrical... • 27 views • 0 helpful votes
1helpful
1answer

Do anyone have a manual for Lutian 5GF-LDE3?

Question edited for clarity. Question moved to Generators. Made in China, so might not be easy. The website Scribd says it has one, but you have to register. Try the link anyway. https://www.google.com/search?q=5gf-lde+diesel+generator+manual ..
12/17/2023 8:53:35 AM • Electrical... • 50 views • 1 helpful votes
0helpful
1answer

Honda Black Max 8450 Generator. I need a picture of the carburetor please.

Question edited for clarity, add maker, put stuff in correct order and spell 'carburetor' correctly. There is a pretty picture of one here. https://www.google.com/search?q=black+max+8450+generator+carburetor ..
1/10/2024 1:15:07 AM • Electrical... • 23 views • 0 helpful votes
0helpful
1answer

Scorpion SC950 Generator. Hi, I am wanting to know the size for the female fuel Thread for it. Thanks Keith

Question edited for clarity. Question moved from Cars and Trucks to Generators. Thar sort of information is never available especially on such a vintage machine, and you don't tell 'why'? You would measure the diameter with an internal Vernier gauge or external on the male connector and then use a thread gauge for the thread pitch. Or you buy a new tank or a new tap. https://www.google.com/search?q=Scorpion+sc950+generator ..
12/5/2023 9:52:58 PM • Electrical... • 42 views • 0 helpful votes
1helpful
1answer

MY GENERATOR WON'T START UNTIL I SPRAY CARBUReTOR CLEANER IN THE CHOKE HOLE. HOW CAN AVOID THIS EXTRA WORK?

Question edited for spelling of 'carburetor'Please don't type in all CAPS, it is considered SHOUTING and is harder to read.Take the carb off and clean all the jets and passageways. Something is blocked and not enriching the mixture. Basically, the choke isn't working and you are doing it manually with the carb cleaner spray.Also do basic things like cleaning and gapping the spark plug...
11/19/2023 12:54:08 AM • Electrical... • 54 views • 1 helpful votes
Not finding what you are looking for?
Champion International Champion Power Equipment 46515 3500 Watt 196cc OHV 4cycle Gas Powered Rv Logo

26 questions posted

Ask a Question

Usually answered in minutes!

Top Champion International Electrical Supplies Experts

Brad Brown

Level 3 Expert

19187 Answers

john h

Level 3 Expert

29494 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66963 Answers

Are you a Champion International Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Champion International Electrical Supplies

  • Champion International Electrical Supplies

Most Popular Question

only runs choke

  • Electrical Supplies
Loading...