Danby DDR4588EE Dehumidifier - Page 5 Questions & Answers
What causes the unit to freeze up?
There are two major causes of a dehumidifier or air conditioner to freeze up the evaporator coil. First is lack of air flow try cleaning or replacing the air filter if it has one; make sure the fan is running and the coils are clean. Second is a low charge of refrigerant in which case it may be cheaper to replace the unit than have a certified repair person fix it. Make sure to recycle the old unit if you replace it.
11/26/2014 6:47:41 AM •
Danby...
•
Answered
on Nov 26, 2014
Humidifier is draining on floor while bucket is not yet full- why?
ck that float level in corner of bucket is free and moves well , also verify that unit is level as this affects the float and amount that bucket can hold , also a ck that drain hole that allows water to enter into bucket is not partways plugged with something , should be pencil size hole there
11/8/2014 1:42:38 AM •
Danby...
•
Answered
on Nov 08, 2014
Dehumidifier danby DDR 501
do the panel indicators light up? is the tank full? is the tank properly seated in position..check the tank switch for operation..
8/3/2014 1:02:01 AM •
Danby...
•
Answered
on Aug 03, 2014