20 Most Recent Goldstar DH504ELY6 Dehumidifier w/ 50 Pints Per Hour Capacity - Page 9 Questions & Answers

0helpful
1answer

My dehumidifier Blyss WDH1012EA need to

Check that the wee magnet hasn't fallen out of the float.
11/13/2021 11:48:11 PM • Dehumidifiers • Answered on Nov 13, 2021
0helpful
1answer

I have a delonghi des 14 dehumidifier. Usually it goes into pause mode for 3 mins when you first turn it on with the yellow light on and then starts dehumidifieing.It now stays in the pause mode forev

Just fixed this problem with my DES14. Its a fault with the circuit board inside the machine and is very easy to fix, even for a novice. Here is how to do it: 1) Open up the machine by removing the screws in the case. (Make sure it is unplugged!) 2) Locate the circuit board on the side of the unit. 3) At this point you have two options. If you want a unit with full functionality you need to buy a replacement circuit board. I found one on MasterSpares (http://www.mastersparesonline.com/product/index/10147) It costs about 30 pounds. Simply remove the old board and replace it. 4) If you want a working unit for no extra cost (but without the functionality of the humidistat) then remove the rectangular white connector from the circuit board which has red,blue,white and yellow wires entering it. Add an extra wire between the central white wire and the red wire that is adjacent to the yellow. (see photo). 5) Re-assemble the unit. If you have opted for the free option the unit will work when you plug it in and switch it on but will no longer cut in and out with different humidities (or have the annoying warm up period). Thankfully the water overflow cut-out will still work. Hope it works for you! Feel free to ask if you are confused! e7f7dffe-36d6-4801-952c-b67a83a8b06c.jpg
11/10/2021 5:30:28 AM • Dehumidifiers • Answered on Nov 10, 2021
0helpful
1answer

Dehumidifier is not working. It shows a code E9. What does this mean.

Impossible to diagnose without a full make and model, but likely a sensor issue. Your Google search query would be make model error code E9 https://www.google.com/search?q=dehumidifier+code+e9 ..
10/13/2021 9:26:25 PM • Dehumidifiers • Answered on Oct 13, 2021
0helpful
1answer

The unit fills the tank with water but won't drain into the drain hose, what can we do?

Clear the blockage and check the flow through the filter.
10/10/2021 3:14:14 PM • Dehumidifiers • Answered on Oct 10, 2021
0helpful
1answer

Keystone kstad70b dehumidifier has stopped draining out the hose. No clogs seen anywhere. What other troubleshooting can I do?

Had an issue with the water draining from the hose. Had worked before and stopped draining all of a sudden. Used a portable air compressor to blow it out. Went to the owners manual and saw that the drain outlet unscrews. Thought the drain hose was internal, taking the bucket off, then removing the drain outlet (2 screws, easy-peasy) Found the soft plastic drain line was kinked enough to stop/slow water from draining clearly. Plastic drain line needed to be heated with a heat gun/hair dryer with a metal file inside to restore the roundness of the tube. Keeping my fingers crossed.
9/4/2021 3:11:01 PM • Dehumidifiers • Answered on Sep 04, 2021
0helpful
1answer

Dehumidifier seeming to not go below 70%?

If the dehumidfier is the right size then it would take a few days to week to get it down .
8/30/2021 4:25:49 PM • Dehumidifiers • Answered on Aug 30, 2021
0helpful
1answer

Haier DE45EK-l. Why does E2 code remain after cleaning?

Not familiar with this brand but all of them are fundamentally the same. If you cleaned with water, make sure the unit is thoroughly dry. Especially electronic components. Also..Make sure that the float for the water tank is correctly installed and not jammed. Some manufacturers set a E2 code for water collection tank issues.
8/26/2021 4:18:07 PM • Dehumidifiers • Answered on Aug 26, 2021
0helpful
1answer

My Whirlpool ad35usv dehumidifier is recalled and

It's been 10 years trying to contact also and still nothing on this whirlpool Ad35usv unit. So might as well say that when they pro rate refund that you will get zero in return now for the few hundred spent to purchase
8/13/2021 2:37:43 PM • Dehumidifiers • Answered on Aug 13, 2021
0helpful
1answer

Hi, I have a Keystone Dehumidifier and want to set it to continuous draining. I have the hose but I need the Adaptor A (1pc) and the screws (2pc) . Can you sell then to me?

They don't sell any parts on this site . I woulld look for stockest on line or Key stone direct thye must have there own wed page
8/12/2021 9:47:52 PM • Dehumidifiers • Answered on Aug 12, 2021
0helpful
3answers

Seem like the compressor is not working very hot

Assuming this is the A/C compressor, right? The compressor will be hot to the touch, the question is whether or not it is engagining when turned on, Check to see if the compressor clutch iis working by having someone turn it on and off while listebibg an observing the compressor clutch. Low refrigerant would or should orevent compressor operation to protect the compressorthrough a safety switch. Good luck
8/6/2021 3:09:21 PM • Dehumidifiers • Answered on Aug 06, 2021
0helpful
1answer

Midea. Why did pump stop working?

The pump may have simply failed.
8/3/2021 7:25:11 AM • Dehumidifiers • Answered on Aug 03, 2021
0helpful
1answer

Meaco zambezi needs repair

Page 16. It appears to be a secret error that only they know the solution. Contact them direct.

Troubleshooting And Fault Codes - Meaco DD8L Zambezi ...

https://www.manualslib.com > ... > Instruction manual
Meaco DD8L Zambezi Manual Online: Troubleshooting And Fault Codes. If Zambezi displays C1, C2, C3, C4 or if the temperature and relative humidity readout continuously flickers ... The relative humidity in the room where the dehumidifier.
7/27/2021 3:35:12 PM • Dehumidifiers • Answered on Jul 27, 2021
0helpful
1answer

I am having trouble with my Frigadaire model # FDD25s1

Could be low on refrigerant
7/24/2021 5:03:48 PM • Dehumidifiers • Answered on Jul 24, 2021
0helpful
1answer

User manual for wdh-735ech-30r

Will my dehumidifier Act as a cooling system
7/23/2021 4:42:59 PM • Dehumidifiers • Answered on Jul 23, 2021
0helpful
1answer

Dehumidifier won't stop running when the bucket is full.

Could be a defective level sensor
7/20/2021 5:38:47 PM • Dehumidifiers • Answered on Jul 20, 2021
0helpful
1answer

What kind of hose do you need to utilize the hose hookup? I'm tired of emptying the bucket.

SOME OF THEM JUST USE A STANDARD GARDEN HOSE . SINCE WE CAN NOT SEE WHAT YOU HAVE
7/16/2021 12:44:37 AM • Dehumidifiers • Answered on Jul 16, 2021
0helpful
2answers

I have a danby ddr7009ree

The continuous drain hole (where the hose is inserted) is clogged. To remove the clog, you will need an 18" long plastic Zip Tie (or something similar. But NO wire cost hangers) that will fit into the hole.
Insert it slowly and push until you reach a bend in the tubing. You will need to gingerly work it past this bend until the Zip Tie bottoms out or you run out of Zip Tie. Then, while rotating it, pull it out slowly. As you reach the end of the Zip Tie, be prepared for some water to follow. Also make sure that the drain hose, when reinserted is not crimped and the end is lower than the drain hose connection. The unit does not have a pump. It relies on gravity to drain water through the hose.

Hope this helped you to solve the problem. Please let me know. Thanks.
7/10/2021 4:19:43 AM • Dehumidifiers • Answered on Jul 10, 2021
0helpful
1answer

I have an error message E9 on my dehumidifier. Its the 043-5796-6 model 70 pints

That is a moisture sensor error and probably needs replacing.
7/2/2021 3:31:58 PM • Dehumidifiers • Answered on Jul 02, 2021
0helpful
1answer

My Keystone keeps shutting down with an EC code. My filter is clean, there's suffient space around the unit and the temperature is set to 60. What is the problem?

EC usually means that the compressor overheated while trying to move the refrigerant through the compression part of cycle. This usually happens when the refrigerant is low due to a leak in the system. Sometimes, you can spot the problem when ice builds up around the coils near the leak. This is not a user-repairable problem. If your dehumidifier is under warranty, contact the manufacturer. The entire system has to be checked to identify the leak. Then after the leak is fixed, the correct amount of refrigerant appropriate to the model has to be added. (In most places, freon and freon replacements must be handled by a trained professional.) I hope this helps. Cindy Wells
7/1/2021 4:43:09 PM • Dehumidifiers • Answered on Jul 01, 2021
Not finding what you are looking for?
Goldstar DH504ELY6 Dehumidifier w/ 50 Pints Per Hour Capacity Logo

6 questions posted

Ask a Question

Usually answered in minutes!

Top Goldstar Dehumidifiers Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Brad Brown

Level 3 Expert

19187 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66931 Answers

Are you a Goldstar Dehumidifier Expert? Answer questions, earn points and help others

Answer questions