20 Most Recent
Panasonic CW-1406BU Air Conditioner Questions & Answers
When we turn on the
Remove battery from remote for resetting timer. Now you can operate with remote. And also reset your unit power isolating power and re plug it. Thanks.
12/31/2010 10:16:51 AM •
Panasonic...
•
Answered
on Dec 31, 2010
Samsung window unit not as cold as before.Is there
Clean condenser (exposed fins on back-metallic aluminum fins)with oven cleaner then throughly rinse with water-let competely dry-if tipped let settle for one hour-clean filter(front side)then clean evaporator with evaporator cleaner.let dry-make sure fins on outside are all straight! make sure there is no restrictions!!Good Luck!!!!
6/20/2009 5:11:03 AM •
Panasonic...
•
Answered
on Jun 20, 2009
Panasonic inverter air conditioner error code h11 pls help
Assuming you have a mini split and not a VRF system (although it is possible the error codes are the same),the h11 code typically indicates a communications problem between the indoor and outdoor units. This could be due to loose or broken wiring, a bad connection at either end or possibly a bad communications board in either the indoor or outdoor unit.
10/11/2021 7:39:18 AM •
Panasonic...
•
Answered
on Oct 11, 2021
Not finding what you are looking for?