Error code 00
Diagnosis display = 00
Abnormality / Protection control = No abnormality detected
Abnormality Judgement =
Emergency operation = Normal operation
Primary location to verify =
Really isnt some fault; reset it disconnecting power unit few minutes.
Additional details could find in the manual:
OPERMANPDF/CWXC104HU.PDFHope helps.
4/16/2011 1:46:06 PM •
Panasonic...
•
Answered
on Apr 16, 2011
H19
Hi,
The H19 indicated that there is abnormality on the Indoor fan motor machanism which shows that the Indoor fan motor mechanism locked
It usually occurs 7 times continuously
You have to check the Indoor PCB and Fan motor rectifying both the things should solve your issue
Please revert me, if you need more assistance, i would be very glad to assist you more.
If you were satisfied with the solution please rate this sollution.
Thanks For using FixYa!
Vinod Kumar J
12/4/2010 5:25:06 PM •
Panasonic...
•
Answered
on Dec 04, 2010
Hello my Panasonic split units air condition is
please read this entire message before doing aniything
that is a problem with you compressor unfurtunatly my recomendation would be to just replace the entire unit but if you have a multimeter and a little patience hear is how you make sure
remove the outside cover and you will be able to see the compressor wich will look like a black tank with copper tubing running into it now that you have located the compressor there will be three wires running into it(usually in a harnes making it apear to be one big wire remove the wire cover off of the compressor there should be two plugs conecting into three pegs on the compressor be sure to make a note of which wire go which pegs it should be clearly marked on the cover as (s) for start (r) for run and (c) for common now set your multimeter to ohm touch your wires from your meter (with the plugs off) to the (s) to (c) pegs write down what you get now the same but (r) to (c) write down what you get then add those numbers together now touch (r) to (s) and that number should equal the number you just added up if not your compressor is bad and your unit should be replaced if under warranty panasonic should take care of that please note that a multimeter costs about the same as a new unit so if you dont have one dont bother trying to diagnose
i hope i was able to help you out
8/26/2010 4:02:53 PM •
Panasonic...
•
Answered
on Aug 26, 2010