Top 20 Hayward H-series Electronic Gas Pool Heater H400 Questions & Answers

0helpful
1answer

The standby light is on. Why does nothing work?

Standby is actually "off". You need to press status until "Pool" or "Spa" is selected than adjust your temperature
5/27/2015 2:59:09 PM • Hayward H-series... • 465 views • 0 helpful votes
0helpful
1answer

What is the fix for an LO error message on Hayward H series heater?

That means low water flow is being sensed by safety flow sensor - normally a pressure switch. It s most cases not a problem, it is just doing its job, informing you that water flow has become restricted and reduced. Most common problem = Dirty filter! either backwash or rinse off the elements. If you have an automated system attached to this heater. It will always show, when heater is Off, this is normal. But it should go away, when pump comes on, if not - check for whatever could restrict water flow to the heater.
6/21/2014 7:46:25 PM • Hayward H-series... • 5,174 views • 0 helpful votes
0helpful
2answers

Hayward h series Bo problem

make sure you have adequate gas pressure
5/17/2014 4:46:04 AM • Hayward H-series... • 5,725 views • 0 helpful votes
1helpful
1answer

Replace igniter on h400

Open the main door, locate the 2 white fabric coated wires, they go down towards the base of the heater. This is your igniter, usually a 5/16 nut driver will be the tool you need to remove it.
7/4/2014 12:53:32 AM • Hayward H-series... • 933 views • 1 helpful votes
0helpful
1answer

H250PED2 integrated control board issues

that is the ignition control (fenwall)
8/12/2014 2:57:42 AM • Hayward H-series... • 246 views • 0 helpful votes
0helpful
1answer

Bypass the LO code on H 350HD Hayward pool heater

"LO" is simply informing you that the Heater is not sensing proper water flow through it! A Flow Problem. A special sensor, called a pressure switch is this source. But... That does not mean it is bad - No, it is in most cases just doing its job! Most common reason - Dirty Filter. A good cleaning of the cartridges, or maybe a breakdown and recharge of a DE Filter, or a good cleansing backwash of your sand filter, will remedy this situation. Or... Check for any OTHER reason or situations water flow may be reduced through the heater:
  • enough water in pool or spa?
  • If you have a weir gate in skimmer, is it stuck in the UP position?
  • Are any valves closed?
  • Do you have a bypass valve at the heater?
    • If open, this will reduce the amount of water going thru heater, close it to the point, LO goes away.
  • Etc
Good Luck - hope this helped.
5/30/2014 8:36:46 PM • Hayward H-series... • 1,274 views • 0 helpful votes
1helpful
2answers

What if code sf and h5 comes up

The two may be related? If the right problems are present... HS = High Limit Sensor SF = Temperature Sensor or Thermistor Heaters Maximum Water Temperature has been Exceeded. Heaters Set temperature not in line with actual water temperature. A few reasons this occurs...
  • Low water flow thru heater, check :
    • Dirty Filter
    • Opened By Pass Valves
    • Plugged pump impeller
    • Dirty/Full baskets at skimmer or pump
    • Anything that may reduce water flow
  • Sensor could actually be doing its job, in a different aspect, Thermostat failure, and water is overheating in spa or pool?
But anyway, your heaters fault code you asked about is does not necessarily mean they failed. They are informing of a problem.
5/25/2014 2:29:46 PM • Hayward H-series... • 708 views • 1 helpful votes
0helpful
1answer

Have a bo code heater keeps cycling on and off

BO code is bypass operation. It means that it is set to operate with an external controller. Things like Aqualink, Aqualogic, Intellitouch, EZ-Touch are all types of automation / external controllers. They have their own temperature sensor and allow remote control operation. To truly find the nature of your issue. I'd start by taking it out of bypass operation and see if the unit fires by itself ( without automation hooked up to it ). The fault may lie with the automation system. You never know.
5/24/2014 6:45:22 PM • Hayward H-series... • 557 views • 0 helpful votes
0helpful
1answer

I have a hayward h400ed2 heater and when turned on to heat the temperature can only be increased or decreased in incriments of 10 to 15 degrees. I also used to get a reading of Lo. It didnt happen all

already answered your earlier post. the code LO signifies that there isnt enough water flow to allow the heater to run. as for the temp, i wouldnt worry about the display. it will never exceed factory setting. sounds like a stuck button
6/16/2014 12:51:24 AM • Hayward H-series... • 241 views • 0 helpful votes
0helpful
1answer

How can i to replace hayward thermistor for H400ED2?

pull off the side panel, the thermistor is located in the header and can be removed by backing out the nut, and then pulling the sensor straight out.
5/28/2014 2:48:00 AM • Hayward H-series... • 341 views • 0 helpful votes
0helpful
1answer

BO code heayer keeps cycling on and off

check to see if proper gas pressure call gas company give them added total thems all your appliances use they probably will give you a bigger meter then everything will run efficiently
5/24/2014 6:47:55 PM • Hayward H-series... • 315 views • 0 helpful votes
0helpful
1answer

How to replace the Thermostat in Hayward pool heater

go to pool store and spend the money on Alladin or Magic Lube. It is a bit expensive and a good sized tube but its designed for your pool system. use it on all your gaskets and threads. DO NOT USE PETROLEUM BASED (vaseline)
6/7/2014 3:23:15 PM • Hayward H-series... • 196 views • 0 helpful votes
0helpful
1answer

POOL HEATER WILL NOT FIRE UP

to start with the basics, make sure there is enough water flowing through the system to activate the heater. you can put sand filter in whirlpool or bypass mode. if there is enough flow through the system, make sure the heater isnt on bypass. make sure that the gas supply is turned on at the heater AND at the meter. if your heater has a pilot light, make sure it is lit. if you still have issues, you will have to get a service company in
5/24/2014 12:22:02 AM • Hayward H-series... • 228 views • 0 helpful votes
0helpful
1answer

Hayward h-series contol panel arrows dont work. cant adjust temp

ensure your getting 24volts to display circ board. you will probably need to replace the display screen
5/9/2014 2:39:22 AM • Hayward H-series... • 342 views • 0 helpful votes
0helpful
1answer

Wiring for hayward 400

http://www.hayward-pool.ca/pdf/manuals/Manual285.pdf this manual will show most of the wiring needed. it is recommended that you hire an electrician to hook up the high voltage portion.
5/26/2014 2:46:00 PM • Hayward H-series... • 205 views • 0 helpful votes
0helpful
1answer

5c error code on hayward heater

according to hayward, this code does not exist. i dont know what else to say.
6/12/2014 3:11:51 PM • Hayward H-series... • 127 views • 0 helpful votes
0helpful
1answer

Lo showing on display won't start

you have an open safety circuit. usually the pressure switch. clean out pump basket, back wash filter to start. you may have a faulty pressure switch
5/2/2014 6:21:26 PM • Hayward H-series... • 115 views • 0 helpful votes
0helpful
1answer

Comforzone pool heater model# 11 215-n likhts but burns about 1 minutes goes out for 30 seconds and then relights

check your gas pressure if not enough it will do that it is a safety
5/20/2014 11:42:29 AM • Hayward H-series... • 65 views • 0 helpful votes
0helpful
1answer

Need manaual for comforzone pool heater 11

Hayward madeComfortzone heaters and most of the parts are long gone. Sorry
5/20/2014 11:26:18 AM • Hayward H-series... • 64 views • 0 helpful votes
0helpful
1answer

Why is my flow low through my heater

pump basket may need to be cleaned out...sand filter may need to be backwashed....cartridge filter may need to be cleaned out
5/6/2014 1:30:06 AM • Hayward H-series... • 61 views • 0 helpful votes
Not finding what you are looking for?
Hayward H-series Electronic Gas Pool Heater H400 Logo

172 questions posted

Ask a Question

Usually answered in minutes!

Top Hayward Pool & Spa Experts

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

john h

Level 3 Expert

29494 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Are you a Hayward Pool and Spa Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Hayward Pool & Spa

  • Hayward Pool & Spa

Most Popular Question

code sf h5 comes up

  • Pool & Spa
Loading...