20 Most Recent Hayward 2HP Pool Pump Motor A O Smith Electric Pool Motor for 56J Frame - Page 2 Questions & Answers


if you have indications of a motor problem, you shouldnt need to disconnect it to diagnose. if your pump is higher than the level of the pool, there should be unions both at the front and top so that it will disconnect from the system quickly and water loss is minimal. if your pump is below the level of the pool, there should be valves to stop water flow as well as the unions to remove it from the system. plan B is to describe what you hear\see and let a pro point you in the right direction.

Hayward 2HP Pool... | Answered on Dec 20, 2015


replacing bearings can be tricky, but if you are willing to try most of these motors use 6203 2rs c3 bearings all for the back bearing, the front could be 3 different sizes. after removing them bring the rotor to your local pool pump motor repair shop, and have them remove and replace. about $20.

Hayward 2HP Pool... | Answered on Aug 13, 2015


How do you know that its getting electricity? Did you check the connections on the back of the motor. If you did and the motor is humming then you need a new starting capacitor.

Hayward 2HP Pool... | Answered on May 11, 2015


Wiring diagrams for AO Smith motors are located on the side of the motor.

Hayward 2HP Pool... | Answered on Mar 04, 2015


Program again the timer. Timer disproggramed.
There is a lot of kind of timers.try to tell me what kind of timer you have.see config of the timer.

Hayward 2HP Pool... | Answered on Sep 03, 2014


if filter pump breaker is on if 220 volt make sure both are on if thats ok you need to check the wiring going to the relay if ok you have a bad relay you need anew filter pump relay for the control box they go out ocassionally

Hayward 2HP Pool... | Answered on Aug 30, 2014


746w = 1 HP so ~560W or 0.56kW

That's the simple answer...the 'real' answer involves motor efficiency / power factor and what load your pump actually presents to the motor. In the end, it will be somewhere around $0.1 an hour or ~$2.40 if ran all day.

Hayward 2HP Pool... | Answered on Aug 14, 2014


ground wire should go to the green screw on the frame of the motor then it is grounded

Hayward 2HP Pool... | Answered on Aug 03, 2014


try turning the shaft on the back of motor then turn on if this doesnt work you need a new one

Hayward 2HP Pool... | Answered on Jul 12, 2014


The motor is made by A.O. Smith in Tippton, OH. You can try calling them, and with any luck you may get a kind soul that can get you a splsh sheild. It is probably not a part you can purchase from a distributor, but that is an option you can also pursue. Good luck.

Hayward 2HP Pool... | Answered on Jun 10, 2014


If pumps don't prime there is a reason:
Enough water in the pool or spa?
Is the o-ring on the lid at the pump pot?
Is the lid tight enough?
Does the pump need to "Pull" water to the pump from the body of water for a great distance or height? If so, then you need to be diligent in getting the water to the pump.
Or the Pump Shaft Seal is worn.

Hayward 2HP Pool... | Answered on Jan 27, 2014


Wire that is between your power source and the pump, needs to be broken/spliced in, with a switch.

If this is a 240 wired motor/pump then Both "hot" wires need to be broken by the switch. If 120, then it is possible to just break the one hot wire. That will be the (Normally) black wire. But be very careful in this as Electricity is "Color Blind"! It does not care what the wire color is. Checking with a meter is always wise & when working with electricity wires, ensure power breaker shut off switches are in the "Off" position.

I posted the two different types of switches you can get at a hardware store.

e81be231-a2c9-4574-8063-9ec4749fa22c.jpg b5311b07-39d2-4a9f-8ee7-aadb802c14c5.jpg

Hayward 2HP Pool... | Answered on Jan 27, 2014


Are you sure? Single phase pool motors are not reversible (unless something weird happened that I can't explain). Three phase motors are reversible, but very rare in residential wiring.

Looking directly at the end of the motor shaft (where the impeller goes) it should spin counter- clockwise. Both of the power wires can be attached to either terminal; there is no "polarity".

Hayward 2HP Pool... | Answered on Nov 18, 2013

Not finding what you are looking for?
Hayward 2HP Pool Pump Motor A O Smith Electric Pool Motor  for 56J Frame Logo

121 questions posted

Ask a Question

Usually answered in minutes!

Top Hayward Pool & Spa Experts

john h

Level 3 Expert

23515 Answers

Marvin
Marvin

Level 3 Expert

85239 Answers

Paul Carew

Level 3 Expert

3530 Answers

Are you a Hayward Pool and Spa Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Hayward Pool & Spa

  • Hayward Pool & Spa

Most Popular Question

need wiring diagram marathon electric

  • Pool & Spa
Loading...