It sounds like the magnetron may have
either failed or is not being supplied with the extremely high
voltage required to run it.
Make sure the !!!!capacitor is
discharged!!!!! before attempting any sort of repair.
Check
the door interlock switches first then the high voltage diode with
either an AVO model 8 on high resistance range for short circuit, the
capacitor can fail and go short circuit, the feed fuse on the primary
of the high voltage transformer and then finally, the magnetron is
best checked by substitution.
Hope that helps.
In most cases, this is a problem with the inverter or a bad magnetron.
Due to the lethal voltages used and produced, I do not recommend that an inexperienced person work on these.
I would recommend that you contact your nearest Panasonic-authorized servicer. You can find one here: