Paragon 4001-00 24-hr Timer Control 120v Ac Cd101 - Answered Questions & Fixed issues

0helpful
1answer

Intermatic T101 24 hour dial switch not keeping time

Replace 120 volt clock motor http://waterheatertimer.org/Intermatic-trippers-and-parts.html#clock Gene Water Heater Timers Save Money If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
3/28/2015 6:57:49 AM • Paragon 4001-00... • Answered on Mar 28, 2015 • 298 views
0helpful
1answer

Paragon 4001 will not shut light off

Replace trippers http://waterheatertimer.org/Paragon-timers-and-manuals.html#4000 Or replace timer with Intematic 120 volt SPST T101 timer or T171 timer with skip-a-day http://waterheatertimer.org/Buy-T100-series-timers.html Gene Water Heater Timers Save Money If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
3/28/2015 6:32:33 AM • Paragon 4001-00... • Answered on Mar 28, 2015 • 339 views
0helpful
2answers

Humming sound

Humming from the timer is not normal. If the timer is still keeping the time accurately it should not be a problem. If the time is innacurate the motor may be failing. Unfortunely this timer is out of production and a replacement motor may be hard to get.

M3017-00 is the motor rated for 120VAC service or M3191-71 is the motor rated for 208/277VAC service.

You can try one of the following to source this motor if you need it.

Grainger 800-323-0620 http://www.grainger.com
Graybar 800-472-9227 http://www.graybar.com
Johnstone (5032563663 http://www.johnstonesupply.com
Munroe Electric 800-777-0172
Atlanta Supply 800-972-5391 http://www.atlantasupply.com
WestsideWholesale 18779397979 http://www.westsidewholesale.com
1/15/2015 8:24:29 AM • Paragon 4001-00... • Answered on Jan 15, 2015 • 1,035 views
0helpful
3answers

Paragon tripper OFF broke, can't

heres a list of places that you can get them Grainger 800-323-0620 http://www.grainger.com
Graybar 800-472-9227 http://www.graybar.com
Johnstone (503) 256-3663 http://www.johnstonesupply.com
Munroe Electric 800-777-0172
Atlanta Supply 800-972-5391 http://www.atlantasupply.com
Westside Wholesale 1-877-939-7979 http://www.westsidewholesale.com
1/15/2015 7:59:35 AM • Paragon 4001-00... • Answered on Jan 15, 2015 • 267 views
0helpful
1answer

I have the Paragon 4001-00 timer. The timer seems to be working okay as far as time and trippers are tripping however it doesnt seem to be engaging our secutiy door lock for the night. Could the conrt

Does the manual override lever move back and forth as trippers pass? If NO, then trippers are bad http://waterheatertimer.org/Paragon-timers-and-manuals.html#4000 http://www.amazon.com/dp/B00441YVCO/?tag=waterheaterti-20 120 Volt timer. When timer is ON, test across terminals 2 and 3 for 120 Volt If 2 and 3 show 120 volt, then timer is delivering power on schedule. Look for loose connections. Loose wire nuts. If 2 and 3 do not show 120 Volt, then timer has failed. Suggest buy T101 as replacement for durability and generic replacement parts. http://waterheatertimer.org/Buy-T100-series-timers.html Crossover wiring from Paragon 4001-00 to Intermatic T101 Paragon 1 to Intermatic 1, Paragon 2 to Intermatic 2, paragon 3 to Intermatic A If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
11/5/2014 10:33:10 PM • Paragon 4001-00... • Answered on Nov 05, 2014 • 788 views
0helpful
1answer

Program timer model 4001-0V

10/15/2014 8:30:42 AM • Paragon 4001-00... • Answered on Oct 15, 2014 • 270 views
0helpful
1answer

My compressor doesn't start

Use following troubleshoot table for paragon or intermatic box timers.http://waterheatertimer.org/How-to-troubleshoot-Intermatic-timer.htmlAdd comment and say what you discover, and for more assistance If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
4/19/2013 3:28:24 AM • Paragon 4001-00... • Answered on Apr 19, 2013 • 71 views
0helpful
1answer

How do i programm the timer

Timer not identified.Copy following links.http://waterheatertimer.org/Paragon-timers-and-manuals.html#Paragon4000http://waterheatertimer.org/pdf/How-to-operate-and-set-T104-timer.pdfAdd a comment and describe timer in detail. If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
4/12/2013 3:45:09 AM • Paragon 4001-00... • Answered on Apr 12, 2013 • 104 views
0helpful
1answer

Need New LCD for Paragon EC71/18S Single Channel

Paragon EC71 single-channel timer is no longer available.Replace with Intermatic ET series.ET1700 series for 7-day.ET70115 for 365 dayhttp://waterheatertimer.org/Intermatic-timers-and-manuals.html#ET1100-1700http://waterheatertimer.org/Paragon-timers-and-manuals.html#EC71 If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
5/29/2012 12:16:53 PM • Paragon 4001-00... • Answered on May 29, 2012 • 225 views
0helpful
2answers

Were can I purchase on

11/23/2011 10:52:02 PM • Paragon 4001-00... • Answered on Nov 23, 2011 • 645 views
0helpful
2answers

Need trippers for model 4001-00

11/23/2011 10:48:56 PM • Paragon 4001-00... • Answered on Nov 23, 2011 • 5,118 views
0helpful
2answers

Parts for paragon timer x2772 for

11/23/2011 10:48:08 PM • Paragon 4001-00... • Answered on Nov 23, 2011 • 611 views
0helpful
1answer

Paragon e74-1200 user manuel

Timer is not identified.
Check options below:

1) Add a comment and describe timer in detail for possible identification

2) Pagragon has EC74 4-channel timer/light controller.
They also show EC7000 7-day digital timer
Also EL74 4-channel timer

Open following links to identify timer and download possible manual(s):
http://waterheatertimer.org/Paragon-timers-and-manuals.html#EC74
http://waterheatertimer.org/Paragon-timers-and-manuals.html#EC4000
9/27/2011 9:00:12 AM • Paragon 4001-00... • Answered on Sep 27, 2011 • 353 views
0helpful
1answer

I need the on tripper

Google search: X2772 tripper

Thank you for including model number.
Paragon is no longer making 4000 series timer or the X2272 tripper.
Some places might still carry the tripper.
Resources:
http://waterheatertimer.org/Paragon-timers-and-manuals.html#4000

Replacement timer for 4001-00 is Intermatic T101 timer:
Crossover wiring from 4001-00 to T101:
Paragon terminal 1 connects to Intermatic terminal 1
Paragon terminal 2 connects to Intermatic terminal 2
Paragon terminal 3 connects to Intermatic terminal A
Resource:
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html#T101

Take a moment and rate answer for accuracy:
And take advantage of fixya expert assistance live.
For a price, expert works with you while you work on timer or any do-it-yourself project.
Fixya is always less expensive than a service call.
9/12/2011 10:36:39 PM • Paragon 4001-00... • Answered on Sep 12, 2011 • 418 views
0helpful
1answer

What is name of srew on timer dial that trip

It's called a tripper.
Question posted under Paragon 4000 series timer that uses X2772 tripper.
Paragon is no longer making that timer or tripper.
http://waterheatertimer.org/Paragon-timers-and-manuals.html#4000

If different timer is needed, use Intermatic crossover to match timer number:
http://www.intermatic.com/customer%20service/competitive%20cross%20reference.aspx
9/1/2011 9:09:01 PM • Paragon 4001-00... • Answered on Sep 01, 2011 • 106 views
0helpful
1answer

Timer not working on 4000

1) If circuit breaker is not tripped or shorted, then timer clock motor has probably gone bad.

2) Some places still sell paragon timers, depending on model number.
But model number given is for 240Volt timer.

3) The clock motor is not available that I can find.
Paragon is no longer making the 4000 series timers or parts
http://waterheatertimer.org/Paragon-timers-and-manuals.html#4000

4) Model number given does not match wiring terminals shown in manual.
4014 is DPST 240Volt timer with 4 wiring terminals labeled 1 2 3 4.
http://waterheatertimer.org/pdf/Paragon-4000-series.pdf

5) Paragon 4000 series timer with terminals 1 2 3 is 120Volt timer.

6) Replace 120Volt timer with Intermatic T101 indoor timer or T101R outdoor timer.
Crossover wiring:
Paragon terminal 1 goes to Intermatic terminal 1
Paragon terminal 2 goes to Intermatic terminal 2
Paragon terminals 3 goes to Intermatic terminal A
http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html#T101

7) Take a moment and rate answer:
And take advantage of fixya expert assistance live.
For a price, expert works with you while you work on timer or any do-it-yourself project.
Fixya is always less expensive than a service call.
8/29/2011 3:18:42 AM • Paragon 4001-00... • Answered on Aug 29, 2011 • 506 views
0helpful
1answer

Paragon 4001-0 Clock is not working Unit

I'm going to guess on this one. The cabinet is probably screwed to the wall. Shut off all power, remove whatever you can from the front to see the screws. If you purchase a new one, the internal parts may fit into the existing cabinet saving you from removing it.

Gary
8/26/2011 5:44:23 PM • Paragon 4001-00... • Answered on Aug 26, 2011 • 226 views
0helpful
1answer

When checking outside light the

Turn off power between each action listed below.

Is dial rotating and keeping time on timer?
This will tell you if 120V is arriving and working at timer.
Cut ground wire and check circuit again.
This can narrow down ground fault problem.
Disconnect wires from timer and connect wires direct to outdoor lights.
This will tell you if timer is suspect.

List all things on same circuit breaker, and test each to find which are working.
Each electrical box is connected to next box and to next box back to circuit breaker.
Open each box and check for loose wires, signs of burning.
This will narrow down location of problem.

When working in main breaker box, the wires on main breaker have power at all times, even when main breaker is turned off. This is true unless meter is pulled. Always stand on dry boards and never lean into or touch anything else when working in main box. Do not hold screwdriver between teeth.
Tape tester leads to wood sticks to keep hands away from voltage.
Test voltage at circuit breaker. Make sure neutral and ground are attached tight on busbar. Make sure black wire is attached tight to breaker. Move black wire to another same-size circuit breaker. Disconnect ground wire and test circuit again to check if ground fault is causing problem.

Resources and illustrations.
http://waterheatertimer.org/See-inside-main-breaker-box.html
http://waterheatertimer.org/How-to-replace-circuit-breaker.html
http://waterheatertimer.org/B220C.html
8/14/2011 10:55:28 PM • Paragon 4001-00... • Answered on Aug 14, 2011 • 223 views
Not finding what you are looking for?
Paragon 4001-00 24-hr Timer Control 120v Ac Cd101 Logo

85 questions posted

Ask a Question

Usually answered in minutes!

Top Paragon Hardware & Accessories Experts

Brad Brown

Level 3 Expert

19187 Answers

Cindy Wells

Level 3 Expert

6688 Answers

john h

Level 3 Expert

29494 Answers

Are you a Paragon Hardware and Accessory Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...