Kohler 35RZG-RES 35 Kw Generator - Page 5 - Answered Questions & Fixed issues

0helpful
1answer

Kohler cv 15s starts up runs a few seconds n stops dead, any idea why?

plugged fuel line or stuck float
5/11/2015 2:08:10 AM • Kohler... • Answered on May 11, 2015 • 99 views
0helpful
1answer

This shower has 3 body spray jets. The lower jet does not work. I need to remove the lower one to see if there is debris in the line, blocking it. It is a Kohler k 8002 cp body jet. How do I disassemb

There are some clips on the top of the spray head that fasten it into place. I found this pic that may help and your Kohler owner's manual should also have more info. 25592176-ozvmlizmijhtkjqpyt2ubpar-3-0.jpg
3/19/2015 1:34:29 PM • Kohler... • Answered on Mar 19, 2015 • 130 views
0helpful
1answer

How to identify older years and models of Kohler generators?

What do you mean? same as any model and serial number plates. Commercial? residential? the same
3/2/2015 6:52:13 PM • Kohler... • Answered on Mar 02, 2015 • 253 views
0helpful
1answer

How to clear a main power overload on a kohler gen

What is missing here is a couple of things, what size generator are we talking? a residential, commercial, what control is on the unit. They all reset in different ways. One sure way is disconnect the battery charger first (VERY IMPORTANT or control board can be damaged) disconnect the negative terminal off the battery. leave off for a minute they re conenct and re energize charger. Fault should clear unless you have done damage due to over load.
3/2/2015 6:43:25 PM • Kohler... • Answered on Mar 02, 2015 • 1,137 views
0helpful
2answers

My generac generator only putting out half voltage

Check stator for shorts
3/1/2015 11:27:18 PM • Kohler... • Answered on Mar 01, 2015 • 118 views
0helpful
1answer

I need a wiring schematic for a Kohler 200ROZD generator

2/18/2015 11:36:12 PM • Kohler... • Answered on Feb 18, 2015 • 113 views
0helpful
1answer

Kohler 40 kw adc controls troubleshooting

wow intermittants are tough to find , the only way ive ever been sucessfull at it is to temp bypass each sensor (lie to controller) to see if it continues to run ,I do not recomend leaving any thing bypassed and not physicaly monitoring it , this temp bypassing is for only the most experienced techs that know normal state of sensors and can simultate them with off machine items
1/30/2015 3:12:31 AM • Kohler... • Answered on Jan 30, 2015 • 153 views
0helpful
1answer

Propane generator had AWSF-52-C spark plug; should I use RS12YC, or RS14YC as replacement?

depends on your climate if genset runs in colder weather run the 14 if not then it's the 12
1/30/2015 2:51:25 AM • Kohler... • Answered on Jan 30, 2015 • 126 views
0helpful
1answer

I have a 17 kW kohler generator. When the power goes out it comes on fine. When the power comes back on the transfer switch transfers back to utility power but the generator never shuts off. I have le

if unit is over 8 years old it has a mechanicial timer for the Cool down run time (after power comes on) these go bad from believe it not "Rust" the timer will need to be replaced with a new model , that most likely will be an electronic timer replacement , now if unit is less than 8 years old . and this is a new install then verify that ,Sense connection on terminal strip on ckt board is connected to land power
1/30/2015 2:37:08 AM • Kohler... • Answered on Jan 30, 2015 • 211 views
0helpful
1answer

Auxiliary light comes on and engine shuts down

Check output voltage. Aux fault.
11/28/2014 12:27:41 AM • Kohler... • Answered on Nov 28, 2014 • 494 views
0helpful
1answer

Kohler 40EFOZD Auxiliary Lamp starts flashing After 2 minutes.

Make sure you have rated speed and voltage on the out put side.
11/28/2014 12:21:37 AM • Kohler... • Answered on Nov 28, 2014 • 314 views
0helpful
1answer
0helpful
1answer

Why does my Kohler 7.3 generator start and runs great for about 5 min. then shuts down.

change the oil to the correct specification first. As the engine runs the heat changes the viscosity and overheats or trips the oil alert switch. If its over 10 years old change the oil alet magnetic switch
6/17/2014 12:03:34 PM • Kohler... • Answered on Jun 17, 2014 • 1,313 views
0helpful
1answer

Why does my generator start constantly?

if a lightning strike was anyplace close (30 yds) it's a safe bet your gonna have to replace the control board in generator also Id have a qualifyed tech ck out your auto transfer switch ,I bet he''ll find that you fried your coils on your switch too , do that before changing control board cus if ya hook up a new one to a bad coil ya just bought two of them
6/4/2014 11:32:42 PM • Kohler... • Answered on Jun 04, 2014 • 249 views
0helpful
1answer

Kohler 6eod

Under voltage would be low output voltage from the generator power head. Verify that the motor is funning at full speed to check the output voltage. Low battery is telling you that the starting battery has low voltage. This could be because the battery is bad or that the alternator is not charging the battery
5/23/2014 5:58:43 PM • Kohler... • Answered on May 23, 2014 • 328 views
0helpful
1answer

How to identify older models and year manufactured?

Hi Jesse, I didn't have a model / serial number to try, but I suspect the date you're looking for is coded in one or both of those numbers. Have a look here & plug the requested info in to see if it returns the info you're after. Good luck! Engine Identification
5/12/2014 11:41:10 PM • Kohler... • Answered on May 12, 2014 • 272 views
0helpful
1answer

Generator output 12 ac at both 110 and 220, when flash it increase to 20, 38 ac, then decrease back to 12ac after a while, any suggestions? thanks

You have overloaded the generator by plugging in too many appliances at one time. A capacitor has likely blown and someone with electrical knowledge needs to troubleshoot and find the damaged part. Appliances draw high amperage and when they cycle on they draw 50 percent or more amps, so a refrigerator that might draw 1000 amps could jump to 1500 when the compressor cycles on. If two or more appliances cycle on at the same time, they will exceed the capacity of the generator, that is unless you have a very large unit.
12/6/2013 6:35:12 AM • Kohler... • Answered on Dec 06, 2013 • 55 views
0helpful
1answer

First start up

Try disconencting the remote start wires between the transfer switch and the generator, if ot still does it you have a bad control board. If it stops, then check the transfer switch for correct wiring of utility and generator power wires, also check with an ohm meter if the run contacts in the transfer switch are closed, that would indicate loss of sensing, or bad board
12/1/2013 10:51:28 PM • Kohler... • Answered on Dec 01, 2013 • 203 views
0helpful
1answer

Kohler boat genny surges

Check fuel supply, carb etc
11/27/2013 1:16:29 AM • Kohler... • Answered on Nov 27, 2013 • 389 views
Not finding what you are looking for?
Kohler 35RZG-RES 35 Kw Generator Logo

1 questions posted

Ask a Question

Usually answered in minutes!

Top Kohler Electrical Supplies Experts

Brad Brown

Level 3 Expert

19187 Answers

john h

Level 3 Expert

29494 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66827 Answers

Are you a Kohler Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...