20 Most Recent Bosch Axxis WTL 5410 Electric Dryer Questions & Answers


yes if its plastic just pop it out to replace

Bosch Axxis WTL... | Answered on Apr 08, 2019


Go to www.repairclinic.com and enter WTL 5410. If this site covers Bosch appliances you will be presented with a list of common replacement parts and more importantly may be able to view a generic Bosch video showing disassembly.

Bosch Axxis WTL... | Answered on Nov 20, 2017


Hello folks try this if you have not gotten this resolved. Your dryers have 2 sensor systems, the first one test the clothes for moisture, the second for the heat. The 1 sensor system drops resistance when the wet clothes are put in the dryer. the shutting down after 5 minutes and lint filter light coming on could be that the dryer isn't sensing the moisture. Now for the fun part, the entire inside of the drum and paddles is the moisture sensor. Try cleaning the inside of the drum with a cleaner to remove any detergent or fabric softner residue. This is crucial if you are using fabric softner sheets as they coat the drum. Also wash the lint filter with soap and water so the water goes straight thru instead of puddling up. Remember to also clean the condenser as this can trigger this issue as well. Hope this helps

Bosch Axxis WTL... | Answered on Oct 05, 2017


There is also another overheat module below the front door too. Check that.
Also, forgive me for asking the very obvious, but have you checked the entire exhaust pipe to make sure that there is no restriction that would cause overheating.

Bosch Axxis WTL... | Answered on Mar 18, 2017


Cycle is interrupted and ''E1'' appears in display.

Condensate hose is blocked in some way. Turn off dryer and check hose.
Condensed water not pumped out (WTL 54 condensation models only). Pump failed.

25808741-gtkp3url2ghtdqenstp5bokb-1-0.jpg Dado

Bosch Axxis WTL... | Answered on Oct 20, 2015


Common faults -
1 The heating elements can fail (meaning open circuit)
2 There are cut-outs (T.O.C's) that might need resetting
3 The thermostats (stats) can trip out or burn out (meaning opencircuit)
4 Moderntumble dryers also have sensors and pcb's (Printed circuitboards) thesehave programs that can fail and circuitry although most should produce an errorcode showing you were the fault is.
5 Faultyconnections and burned wires may also be the fault.



Free tumble dryer repair videos


We have a Free full video library on appliance repair video’s

Bosch Axxis WTL... | Answered on Apr 10, 2015


Most Bosch dryers have a heater reset button behind the main rear panel. If this thermostat has tripped, there is a REASON, resetting it may make things work for a short time but your issue is bound to return. There are many other things to check on Bosch dryers to ensure proper air flow throughout the dryer and house venting. Pleazer Appliance...

Bosch Axxis WTL... | Answered on May 20, 2014


this is normal operation it turns the drum one direction then the other this is because of the way it condensates

Bosch Axxis WTL... | Answered on May 04, 2014


Check the little button that the door pushes in when you close the door (door switch).

Bosch Axxis WTL... | Answered on May 02, 2014

Not finding what you are looking for?
Bosch Axxis WTL 5410 Electric Dryer Logo

117 questions posted

Ask a Question

Usually answered in minutes!

Top Bosch Dryers Experts

Cindy Wells

Level 3 Expert

6068 Answers

Marvin
Marvin

Level 3 Expert

85222 Answers

Lawrence Oravetz

Level 3 Expert

10543 Answers

Are you a Bosch Dryer Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Bosch Dryers

  • Bosch Dryers

Most Popular Question

wte 86300us 05 dryer not drying clothes

  • Dryers
Loading...