RTO American Heat Tankless Electric Water Heater - Answered Questions & Fixed issues

0helpful
1answer

I have an American Heat AHK1. The power went out and when it came back on the heater no longer turns on or even lights up. The digital display showing on/off and temp no longer lights up. Is there a

If you had a power surge at your home, and no more power seems to be going to the heater, you must make sure that none of your wires from the load center all the way to the heater are intact and all have been wired correctly and none are lose. If you must be very careful reading manufacturing dates as these dates are actually displayed backwards and the year is actually displayed as the month, you may in fact have an older heater, as sometime when these heaters are purchased by distributors they don't get to sell them until way after or they have had one in storage for a while when they decide to sell them. I have spoken to the guys at the factory and they are very informative, I don't see how they could not help you as I deal with them on a daily and we always try and help there customers, why don't you bring the heater in there service department is great it only takes 5 minutes to fix the heater. If you mail it in its only 24-72 hr turn around.
4/7/2014 4:03:15 PM • RTO American... • Answered on Apr 07, 2014 • 130 views
0helpful
1answer

I have model AH21 Tankless Water Heater and it is not heating the water

try these steps - hope it helps
  • Selected temperature on your tankless water heater is too high. Select the lower temperature.
  • Inlet filter is dirty... clean it.
  • Make sure that there are no water path obstructions, including faucet aerators, shower heads...
  • Is the heater using the specified gas type?
  • Temperature sensors are loose... ensure that sensors are firmly mounted and are making contacts.
6/7/2012 3:38:41 AM • RTO American... • Answered on Jun 07, 2012 • 355 views
0helpful
1answer

My American Heat ADK-1 is

Hi,
The problem is usually the thermal saftey cutout switch....this can be manually reset, but if it continues to cutout then the thermostat is bad and needs to be replaced...

You can see all of the parts and where they are located by going here and checking out page 4

heatman101
9/8/2011 10:54:56 AM • RTO American... • Answered on Sep 08, 2011 • 2,657 views
0helpful
1answer

Tankless heater says standby and

You must to make sure that you have not used too much teflon tape, and also that the flow sensor is still inside the inlet pipe. For example these units some with a reed switch type flow mechanisim which when flow is detected it opens the door for the electricity to pass through the unit. so no Flow no power, or in your case there maybe something clogged, or your flow sensor is not inside the inlet pipe, also if this unit has been installed previously and had been working for sometime now, then check on the inside pipe behind the screen you will notice there is a small black or either white bullet style flow switch, if this flow switch is stuck on the inside of the unit, this is your problem, if not its a reed switch, you can call 1-888-818-4328 and ask for an ADK reed switch see picture attached
2/18/2011 8:42:39 PM • RTO American... • Answered on Feb 18, 2011 • 3,471 views
0helpful
1answer

ADK-1 Super------------why is it that I have to

If you live in an area where you have hard water it can destroy pretty much any tankless water heater, but it seems that you may have another problem, I speak to them on a regular basis and everyone there seems to speak English and Spanish, its very important to make sure that this unit is installed by a liscensed person, whom will check your wire gauge, and breaker size, if you use 240v this unit can draw upto 66 amps, so its important to have an electrician size your heater for the correct voltage.
2/18/2011 8:36:17 PM • RTO American... • Answered on Feb 18, 2011 • 255 views
0helpful
1answer

I have an American Heat adk-1. As of this morning

You need to get a real tankless water heater, I had one of this brand and what a waste of money, when you call the company they do not speak very good English and if you talk to Richard whom is supposedly the VP he is as dumb as a mule.
4/2/2013 3:25:41 AM • RTO American... • Answered on Apr 02, 2013 • 1,254 views
0helpful
1answer

Hi, is not working, the machin is turn on but we

Possible causes and solutions:
  1. Safety Thermal Cut-Out Tripped, Reset.
  2. Not enough flow rate to activate unit, clean filter screen at unit, clean aerator at faucet.
I hope this has helped. Please rate the answer as to it's helpfulness. Good Luck and have a great weekend. Jeff
4/4/2010 4:48:05 AM • RTO American... • Answered on Apr 04, 2010 • 312 views
0helpful
1answer

No hot water can't even take a shower

If there is only cold water coming out from the water heater, there is no doubt that your RTO water heater
is defective.
1. Shut the power supply going to your heater off.
2. You can check on it, by opening it up.
3. Trace the wires coming from the power supply.
Using a multitester, check the continuity of each
line. Set the tester to Ohms 1 x 10. Put the multi
tester probe to each end of the electrical line, one
line at a time. The pointer must point to zero.
Otherwise, it must be replaced.
4. Test the heater coil for continuity. One of the multi
tester probe must be placed at the common termi-
nal. Put the other probe to the other terminals. The
pointer must be at zero, otherwise, you can
replace the heater unit, since this is already
busted.
12/11/2010 9:35:16 PM • RTO American... • Answered on Dec 11, 2010 • 207 views
0helpful
2answers

Water Temperature Fluctuates

no the tub faucet is the only faucet that is wide open you might have to not run full blast on the faucet , your tankless water heater is under sized for the application, to many gallons per min going thru the unit, look at the rating chart for your unit, the r94 is only 9.4 gallons per min, and a tub faucet can be upto 5 gallons per min, depending on the faucet,,
10/3/2009 5:03:44 PM • RTO American... • Answered on Oct 03, 2009 • 434 views
0helpful
1answer

Taknlees system overheated and turned off.

The high limit should be on the top side of the unit near the exhause. Check your manual for location and to find out if it can be reset.

Mike Wenger
4/5/2009 12:11:45 AM • RTO American... • Answered on Apr 05, 2009 • 147 views
0helpful
1answer

Jayco expanda wiring diagram

10/30/2017 5:43:58 AM • RTO Water... • Answered on Oct 30, 2017 • 622 views
0helpful
1answer

Water heater gets hot, no hot water at fascets,

Bad faucet cartridge: walk-thru on following link http://waterheatertimer.org/Crossover.html If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
10/29/2017 7:32:46 AM • RTO Water... • Answered on Oct 29, 2017 • 293 views
0helpful
1answer

I have a Cantebury park model with an electronic ignition

What water pressure reading do you have? IS there a mixer in the system? What is the exact model number?
5/4/2013 9:18:10 PM • RTO Water... • Answered on May 04, 2013 • 88 views
0helpful
1answer

Pilot goes out when dialed back to on

no I dont think you have a mother board. If there wasone it would be in a box of some sort on the top or right near the top mounted on the side.

If you replaced the coupler, I would say the gas valve is bad. Go to you local supply store and get a new valve. you should have 3 connection on the valve, the main gas feed and the main burner and your coupler.

Make sure you turn off the water at the main, drain it all down and when you have all the connection moved get a large channel lock or pipe wrench and turn the valve counter clock wise use tape or dope on the section that goes into the tank and tighten it up, hook up your other pipes and test for gas leak with soap and water.

Make sure when you buy the valve you get a match to the kind of gas you have natural or L P one will not work with the other.

OH check for gas leaks

Best of luck Tom
9/8/2011 6:36:16 PM • RTO Water... • Answered on Sep 08, 2011 • 164 views
0helpful
1answer

The pilot is ok.the main burner does not come on

First check and see if the dial on the gas valve is on the ON position. Next turn the thermostat up all the way.if it does not come on then, this sounds crazy, but, tap the gas valve twice lightly with the back end of a screw driver, sometimes a spec of dirt can clog the gas valve and this releases it. if it still doesnt come on, you need a Volt Ohms meter or multi meter, set the meter to millivolts, you want to connect the 2 leads from the meter to the terminals on the gas valve that the 2 wires from the pilot generator, located next to the main burner underneath tank. turn the meter on and the millivolts should read a minimum of 400 milivolts, if lower, replace pilot generator. If still doesnt work, replace gas valve.
9/1/2011 1:22:02 AM • RTO Water... • Answered on Sep 01, 2011 • 409 views
0helpful
1answer

Hi, I have an old Atwood gas water heater (model

That is not a model number that sounds familiar. Should be a tag on side of water heater behind cover, outside. If it has the little arm adjustment for temperature on top of gas valve, simply move it over a little to the left to increase water temperature, and try it until temperature is what you are happy with.
I'm assuming when you say it goes out completely that the pilot remains on and water heater re-lights when called for? If you adjust that temperature lever over, and water still doesn't get hot, you need to replace gas control, as thermostat is built in to it.
7/2/2011 8:24:09 AM • RTO Water... • Answered on Jul 02, 2011 • 1,002 views
0helpful
1answer

Where can I get a Service Manual including error codes, of HITACHI Package unit RUA-30AT3S?

I am not sure they are available to non Hitachi service centres. https://documentation.hitachiaircon.com/glb/en/pac/rua-at3s
3/17/2024 4:06:16 PM • Water Heaters • Answered on Mar 17, 2024 • 22 views
0helpful
1answer

VAILLANT ECOTEC PLUS 831 BOILER , with an error code of F79, which is not in the handbook, its not working at the moment, already had a local plumber out, who didn't know a lot about F79 code

Cannot find the fault code . There are vidoes on u tube saying how to reset thr code By pressing the reset button . If this does not work youcan ccontact vaillent on there web page . I have a mate who works for them i will ask him as well
2/12/2024 9:14:32 PM • Water Heaters • Answered on Feb 12, 2024 • 33 views
0helpful
2answers

Envirotemp water heater

Do I need to insulate this heater out in the shed? Freezing temperatures
2/6/2024 11:45:03 AM • Water Heaters • Answered on Feb 06, 2024 • 570 views
0helpful
1answer

Remeha avanta plus combi problem

Call a engineer
1/11/2024 7:52:09 PM • Water Heaters • Answered on Jan 11, 2024 • 2,251 views
Not finding what you are looking for?
RTO American Heat Tankless Electric Water Heater Logo

32 questions posted

Ask a Question

Usually answered in minutes!

Top RTO Water Heaters Experts

Brad Brown

Level 3 Expert

19187 Answers

Sean Wright
Sean Wright

Level 3 Expert

2045 Answers

Paul Carew

Level 3 Expert

3808 Answers

Are you a RTO Water Heater Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...