20 Most Recent Robinair 6 Cfm 2 Stage Vacuum Pump, R 12/R 134a Questions & Answers


I seems to be problem with pump capacitor.change capacitor & i hope it will work fine.

Robinair 6 Cfm 2... | Answered on Aug 26, 2011


During off, but essentially it would be the same when on....

Robinair 6 Cfm 2... | Answered on Feb 17, 2011


Yes you can,as long as you have fresh oil & it'll pull the system below 500 microns,you shouldn't have a problem.

Robinair 6 Cfm 2... | Answered on Jan 09, 2010


the robinair listed on the robinair page shows the pump is 110 volt. have you checked the nameplate on YOUR pump if it is rated at 120/240 volt? Please get back to me.

Robinair 6 Cfm 2... | Answered on Oct 13, 2009


Just Check power cable/13A fuse & starting capacitor.

Robinair 6 Cfm 2... | Answered on Aug 31, 2009


Check your pump oil level,It should be middle of sight glass while pump is runing & try to use origenal vacuum pump oil.

Robinair 6 Cfm 2... | Answered on Jun 13, 2009


Open oil drain solenoid and clean solenoid plunger with dry soft clots and replace it. After that check the apply vacuum, if you still have same issue then you may need to replace oil drain solenoid.
Hope this will help to solve your problems.
Thank.

Robinair... | Answered on Aug 09, 2020


Please call the manufacturer on toll free number for assistance shown in link below:

https://www.robinair.com/sites/default/files/03-84.pdf

Robinair... | Answered on Jun 30, 2020


may be the cause is no power source, try to check voltage reading at your breaker, if the breaker itself has a power then the problem cause at your ROBINAIR, if you have guts to open the unit ?, try it and find which cause the trouble , thank you and GOD BLESS.

Robinair... | Answered on Oct 25, 2018

Not finding what you are looking for?
Robinair 6 Cfm 2 Stage Vacuum Pump, R 12/R 134a Logo

11 questions posted

Ask a Question

Usually answered in minutes!

Top Robinair Measuring Tools & Sensors Experts

Hasan Khan Amran
Hasan Khan Amran

Level 2 Expert

181 Answers

Sheldon Dedek

Level 3 Expert

912 Answers

Mike

Level 3 Expert

4372 Answers

Are you a Robinair Measuring Tool and Sensor Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Robinair Measuring Tools & Sensors

  • Robinair Measuring Tools & Sensors

Most Popular Question

oil level full during

  • Measuring Tools & Sensors
Loading...