My brand new sharp carousel microwave has a

First of all is it really the membrane keypad itself, or just the clear protective sheet over the keypad which you're supposed to remove when it's new?

Keypad trouble can be serious, so until it is repaired, please leave it unplugged or leave the door open when it's not in use, and please do not leave it running unattended.

If it's really the keypad and less than one year old, it would be fully covered under warranty as long as it's not been damaged by outside forces. I'd suggest contacting the manufacturer to get it fixed free.

You can contact Sharp at 1-800-BE-SHARP (1-800-237-4277) or visit them online.

If it's out of warranty, or
if you (or someone you know) might want to replace it yourself, I have uploaded a handy guide with pictures showing you what's typically involved.

You can order parts from Encompass here or you can call them toll-free at 866-779-5835.

If you would like to have us do this repair for you, we do that for $39.95 plus part costs.

Feel free to contact me directly (and please remind me of your full model number from the tag on the unit) for more information & help.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.

William E. Miller, AS-EET
[email protected]
http://www.microwavedisplay.com
Microwave Oven Control Panel Repair Nationwide
8/1/2009 1:41:50 PM • Emerson MW8108P... • Answered on Aug 01, 2009
0helpful
1answer

How do i change the lightbulb

remove outer shell and you will have access to the bulb
7/9/2009 6:30:14 PM • Emerson MW8108P... • Answered on Jul 09, 2009
0helpful
1answer

MOUSEPAD DOESNT WORK! HELP HELP HELP!

Try here.

They have very good support links.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.
6/16/2009 8:18:08 AM • Emerson MW8108P... • Answered on Jun 16, 2009
0helpful
1answer

Emerson model MW8117W Microvave

If the microwave is rotating & the light is on, then the door switches have been satisfied. Some times the connections to the magnetron get crystalized. I have repaired mine just by pulling the leads to the magnetron on and off a couple of times, When testing always have the microwave loaded with at least a glass of water. And be careful because the capacitor in the microwaves hold a charge. Short out and drain the capacitor by touching both termnals with a metal objest like a screwdriver. Or unplug the leads on the capacitor befor beginning the repairs.
5/18/2009 8:45:46 PM • Emerson MW8108P... • Answered on May 18, 2009
0helpful
1answer

I just purchased an Emerson 1000W Microwave, Model

The unit may be more powerful than your last one. if its probably is normal 1100 w is a lot of power. if it works well and you in joy it, then you will soon be used to the new sound of power Good luck DFD
4/13/2009 9:41:49 PM • Emerson MW8108P... • Answered on Apr 13, 2009
0helpful
2answers

My microwave is um...sparking kind of...inside

Quite often this is due to grease or food particles stuck to the inside of the oven or stuck on or behind the waveguide cover.

The waveguide cover is usually about the size of a playing card and held in place by a plastic rivet.

It can be fragile, and the metal edges behind it can be sharp, so be careful!

The cover and the metal behind it should be cleaned with a mild, non-ammonia cleaner.

If the cavity metal of the oven is chipped or charred, it will have to be sanded smooth and clean.

Then you can apply some high-temperature appliance paint, available from places liek Wal-Mart or Lowe's.

If your waveguide cover is burned, it will need to be replaced.

You can find helpful exploded view diagrams and order parts by entering your full model number here: http://tinyurl.com/gv383

For more help from Emerson http://www.emersonradio.com ; Get help using your appliance 1-800-898-9020 ; Get help locating a servicer or parts 1-800-695-0098.

1/25/2009 3:05:29 AM • Emerson MW8108P... • Answered on Jan 25, 2009
0helpful
1answer

Clock works, timer works-but turntable and other functions stoppe

you have a bad control board . this board had 2 relays one for the magntron and one for the turntable and the cooling fan together . when the turntable goes out so does the cooling fanm and the microwave overheats ...... there is no good fix for this , the control will cost more than a new microwave . please do not use with this happening . i have see them start on fire when it overheats . please be carefull good luck
1/15/2009 8:21:58 AM • Emerson MW8108P... • Answered on Jan 15, 2009
0helpful
2answers

Emerson microwave oven model number MW8115SS

You don't state how old your oven is, or if you tried other food items afterwords. I also assume you inspected for foreign metal objects in the oven? If it does this whenever you attempt to cook in it, then it sounds as if your oven may have a wave guide cover malfunction or burned area.This part can be replaced by the consumer in most cases, but only after consulting with a trained technician or your parts supplier.
1/11/2009 9:04:42 PM • Emerson MW8108P... • Answered on Jan 11, 2009
0helpful
1answer

Emerson microwave oven model mw8115ss

There is not much you can do about this. There may be a reset button on the control panel, try it. You can try slamming the door a couple of times & looking on the back for any fuses. If this fails, scrap the oven & get a new one, as they are generally not worth repairing.
1/5/2009 12:02:35 AM • Emerson MW8108P... • Answered on Jan 05, 2009
0helpful
1answer

Melted turntable support

Yes, that's part # WB06X10138 (coupler) and you can get it here.

You will need to remove the bottom cover of the microwave and remove the turntable motor to get the new coupler in.

We're happy to help and we appreciate your thoughtful rating of our answer.
1/1/2009 11:11:51 PM • Emerson MW8108P... • Answered on Jan 01, 2009
0helpful
1answer

Can't set the timer

Many Emerson microwave owner's manuals are available for free download here.

Even if yours may not be there, there might be one close enough to help you .

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.
12/28/2008 7:53:30 PM • Emerson MW8108P... • Answered on Dec 28, 2008
0helpful
1answer

My MW8108p is flashing and making noises

Do not use the oven! It sounds like the wave guide cover is burned and this poses a fire hazard should you continue to use it. Have a technician look at it and if this is the problem, it is usually a cheap fix.
11/23/2008 11:21:20 PM • Emerson MW8108P... • Answered on Nov 23, 2008
0helpful
1answer

MW 8115 SS Turntable doesn't turn

You probably have a stick door switch or broken door switch mount.

If you or someone you know decide to look into it, we have critical safety information, info on door switch diagnosis and replacement, and disassembly information at our site, and our link is at our listing here on FixYa.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.
8/21/2008 4:25:30 AM • Emerson MW8108P... • Answered on Aug 21, 2008
0helpful
1answer

Microwave runs on its own

This is usually caused by either a bad door switch, a loose door switch mount, or occasionally a problem on the control panel.

Even though a door switch clicks, it may still be bad inside. Its continuity must be checked.

Door switch or mount trouble can be caused by slamming the door or by opening the door while it's cooking without hitting the Stop pad first.

There are plastic mounts inside the microwave which hold the door switches and onto which the door latches lock when you close the door.

The screws on these mounts may be loose. If they get too loose, the switches will not be activated properly.

Sometimes it's a broken tab on the switch holder, allowing the switch to rotate just out of position. Other times, it's a broken tab on the switch holder, allowing the switch to rotate just out of position. This tab can be hard to see, since it is under the bottom edge of the switch.

One test that sometimes helps is to gently lift up on the door or handle as you try to start it. If it works or tries to work, then it's a door switch mount or door alignment issue.

If you or someone you know decide to look into it, we have critical information on safety, disassembly and door switches at our site, and our link is at our listing here on FixYa:.

If you think the problem is on the control panel, we repair these nationwide by mail for $39.95 postpaid in most cases.

We're happy to help you and we'd appreciate your thoughtful rating of our answer.
7/23/2008 4:00:39 PM • Emerson MW8108P... • Answered on Jul 23, 2008
0helpful
1answer

Amana micorwave

A microwave can be dead for many reasons.

It may be the fuse, which is usually located on the floor of the oven behind the control panel or between the door switches.

If the fuse is good, it may be an open thermostat or thermal cutout (TCO) / thermal fuse on or near the magnetron or on top of the cavity / body of the oven.

If it goes dead for a while during or after cooking then comes back on, the magnetron is probably overheating and causing the magnetron thermostat to open.

Then when it cools, it closes the circuit and allows power through again.

When checking thermostats, if it has a hood fan thermostat, that should read open, as opposed to the others, which should read closed.

If it went dead almost immediately after pressing the Start pad, that's usually a shorted high-voltage capacitor.

If it went dead a few seconds after pressing the Start pad, that's usually a failing high-voltage transformer.

If it goes dead or blows the breaker (or GFI) when you plug it in or open or close the door, then there's a problem with a door switch or door switch mount.

If it's intermittent or random, it may be a bad connection, usually on the control board or a loose fuse holder, or even an intermittent fuse.

You should do a continuity test on the fuse while it's in the holder (with the microwave unplugged, of course) then turn the fuse by hand or take it out and put it back in, then test it again.

If you remove the fuse, then press the meter leads against the ends, it can allow internal contact to be made and make a bad fuse appear to be good.

If you or someone you know decide to look into it, we have critical safety information and disassembly information at our site, and our link is at our listing here on FixYa.

There should also be a "mini-manual" hidden inside the unit behind the control panel or hidden on the left side behind the grille, which is very helpful when troubleshooting & testing.

You can usually find helpful exploded view diagrams and order parts by entering your full model number here.

We're happy to help you and we'd appreciate your thoughtful rating of our answer.
7/23/2008 3:49:15 PM • Emerson MW8108P... • Answered on Jul 23, 2008
0helpful
1answer

Blower fan for solderable reflow oven not working contineousley

check the control bord, and blower fan.
4/8/2008 2:11:25 AM • Emerson MW8108P... • Answered on Apr 08, 2008
0helpful
1answer

Emerson Micorwave oven MW8108P

Generally, the most common causes of a failure to heat are:

- bad door switches or door switch mounts
- loose connection at the magnetron
- problem or loose connection on the control unit circuit board
- bad magnetron or other high voltage part such as high-voltage rectifier diode

If you or a friend decide to look into it, we have critical safety information, info on door switch diagnosis and
replacement, and disassembly information at our site, linked here on Fixya: http://tinyurl.com/yzjozk
11/5/2007 7:23:41 AM • Emerson MW8108P... • Answered on Nov 05, 2007
0helpful
1answer

Microwave Keypad Is Hot

check blower fan, and maintained gap between oven and wall at last 2 feets. some heat comes to pad very heat may be some prolem. check every thing and reply me.
10/13/2007 2:15:43 AM • Emerson MW8108P... • Answered on Oct 13, 2007
0helpful
1answer

Keypad works only half of the time!!

You have a problem due to Membrane key panel which is fixed on front panel.As i can understand from your complaint that Membrane key panel to be replaced. For replacement of bulb only you have to do is to open the screws of bulb housing and it is very simple to replace the bulb as you normaly replace in your home.remove from it's socket and get the similer type of bulb to fix.
8/3/2007 1:25:12 PM • Emerson MW8108P... • Answered on Aug 03, 2007
0helpful
1answer

Microwave works intermittently

This is most commonly due to a failing door switch or door switch mount. But it may also be a bad connection or bad relay on the control board, which we repair nationwide for $39.95. Also, it could be a loose connection at the magnetron. If you or a friend decide to work on it, we have *critical* safety, disassembly, and troubleshooting info (as well as a text file which helps in diagnosing and repairing door switch problems) at our site, which is linked at our listing here on FixYa: http://tinyurl.com/yzjozk You can find helpful exploded view diagrams for similar models here: http://tinyurl.com/gv383 You can order parts at http://www.wehaveparts.com
5/29/2007 9:52:19 AM • Emerson MW8108P... • Answered on May 29, 2007
Not finding what you are looking for?
Emerson MW8108P Microwave Oven Logo

55 questions posted

Ask a Question

Usually answered in minutes!

Top Emerson Microwave Ovens Experts

Cindy Wells

Level 3 Expert

6688 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Paul Bade

Level 3 Expert

1818 Answers

Are you an Emerson Microwave Oven Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Emerson Microwave Ovens

  • Emerson Microwave Ovens

Most Popular Question

when use microwave sparks in

  • Microwave Ovens
Loading...