Honda Mmd 5000 Watt Generator W/ Engine Ngk 6000H - Page 4 Questions & Answers
How to measure the stator on a honda ex 5500 generator
You need a volt meter an ammeter and a variable power supply and with ohms law the resistance can be calculated. V=IR thus resistance is the applied voltage devided by the current R=V/I Set the psu till a convenient current is indicated on the ammeter and take an accurate voltage reading and do your calculation. Normal multimeters cannot read reliably below one ohm and these rotors do have a low resistance
Electric starter will not work on honda e u 3000 generator
Hi there! 1) Check battery with a load tester and recharge / replace if necessary 2) Check the ignition switch for loose wires or if the switch is okay 3) Remove the starter and try to run it against a piece of wood ( Have you seen the wooden hammer handle of an auto electrician?) If you can stop it then the motor needs repair/replacement it is often cheaper to replace than repair it excluding labour!! 4) Check ringear on the flywheel and the pinnion of the starter motor for binding and wear. Keep these tips in mind for your Automobiles too
My 5.5kva Honda generator has no voltage and voltage meter also not showing voltage. What can be wrong?
Hi there I had a similar problem years ago. 1) check brushes on the sliprings of the alternator 2) There is a small pcb on the brush gear and an electrolytic capacitor some diodes etc. check for bad joints or capacitor 3) lift off one brush from sliprings and connect for a couple of seconds a 12 volt battery to it. Why? The rotor must have some residual magnetism for it to develop excitation and sometimes if the genny was not used at all for a long time then that magnetism sometimes die away. It also happen if the genny was disassembled for one reason or another Good luck
Not finding what you are looking for?