Top 20 Hobart HL600 Legacy Stand Mixer Questions & Answers


It's meant to tell the operator that the bowl is not in proper operating position. If the bowl is in the proper position then the bowl in switch may be bad.

Hobart HL600... | 262 views | 0 helpful votes


Because of the very high voltage on the output of the Inverter drive, I do not want to be responsible for your injury or death from you servicing this machine without proper training.

Hobart HL600... | 295 views | 0 helpful votes


The manual I just read says to unplug the unit from wall an allow to set for a couple of minutes. This will reset it. An code should go away. If not contact service for repair. Their web page has a service manual you can down load. Maybe repair yourself if possible. I would do the reset first.

Hobart HL600... | 312 views | 0 helpful votes


The Legacy is an electronic mixer and the transmission does not have any gear, and it frequency convertor that works in phases 2 and 3. If the hook struggling when turns, check the transmission belt locasted at the top of the mixer, remove the cover first.
If the belt is loose, tense it with the screw on the base of the motor or replace the belt. If you can not fix it, let me know and I'll try something else.

Hobart HL600... | 115 views | 0 helpful votes


There are no schematics for the reluctance drive unit to get details of every resistor, at a technician level. Perhaps try resourcing the company that makes the drives for Hobart. The troubleshooting of the drive is complex and dangerous because of residual high DC voltages. Use extreme caution while near the drive. Voltages take a while to dissipate.

Hobart HL600... | 87 views | 0 helpful votes


It's telling you that the bowl guard is open. If the bowl guard is in place and closed then you could have a bad bowl guard switch.
Check www.hobartservice.com for your local Hobart office.

Hobart HL600... | 366 views | 0 helpful votes


Hello & Welcome to FixYa

Please get back to me with a detailed question about your Hobart as the question is still unclear because trouble code is not written.

Kevin

Hobart HL600... | 490 views | 0 helpful votes


Leave the breaker off for at least one minute then try it. If that doesn't take care of it then you will need to have Hobart come out and check the frequency inverter (drive).
www.hobartservice.com

Hobart HL600... | 116 views | 0 helpful votes


Check www.hobartservice.com for your local Hobart office.

Hobart HL600... | 95 views | 0 helpful votes


Check www.hobartservice.com for your local Hobart office.

Hobart HL600... | 56 views | 0 helpful votes


Planetary takes six ounces 150 weight gear oil if completely drained (i.e. Exxon Spartan EP 150 or equivalent). Transmission uses one gallon 460 weight (yeah, 460 weight!) gear oil (Exxon Spartan EP 460 or equivalent).

Hobart HL600... | 651 views | 1 helpful votes


Hi, btperduell

below is a copy of an e-mail from Horartservice.com. I searched the web forhours for the correct oil and could not find any info so I e-mailed Hobart. The Planetary is a different part from the transmission andthe sight glass on a M802 is for the oil in the transmission. The answer that Hobart gave is not an NSF oil. Ineeded the oil for the planetary section on a model M802. Even the directionssay that it is normal for a drop of oil to occasionally drip from the seal.That is where the dough hook attaches. I am in the process of researching the oil and Exxon / Mobildoes make a NSF version. I just need to find somewhere I can buy less then a 55-gallondrum. The above mixer only uses 6 ounces. Take care and stay safe Thank you Mike Hobart E-mail follows ============================================================== Mike, Hobartuses "EXXON SPARTAN EP-150 (6 oz)" in the M802 planetary. Hobart part #102973-13. This IS NOT a food grade oil. If you mixer is leaking you shouldhave it serviced. Service, parts , lubricants and information canbe obtained by contacting your local Hobartoffice in [email protected] (412) 788-5380. Steve Davis Field Engineer - Food Machines Product Service - Tech Support
b>

Hobart HL600... | 770 views | 0 helpful votes


This sounds the thermal reset is tripped have you looked for a red reset button on the mixer? that is usually what fixes that

Hobart HL600... | 117 views | 0 helpful votes


Hobart mixer, HL300, stops and flashes as oc3, wounded what is broken?

Hobart HL600... | 1,015 views | 0 helpful votes


20 quarts.

Hobart HL600... | 201 views | 1 helpful votes


Hola amigo, mi nombre es ramon, a mi me sucedio algo parecido, primeramente debes revisar los 24V Ca en la tarjeta, este es rectificado a 24v cd y 12 Cd quienes son los que alimentan el control, no te desgaste buscando en los interruptores de proteccion, el display debe encender autamaticamente cuando la maquina esta energizada, esto es un defecto al parecer comun en estas maquinas, esta tarjeta tiene un Circuito integrado que alimenta a relay C3 y este a C2, hay varios relay de control los cuales pueden o no activarce pero es fundamnetal que arranque el microprocesador de esta tarjeta, quizas con un poco de tiempo puedas reparar esta tarjeta revisando el relox de control y todos los circuitos de control para el funcionamiento de la misma, hubiera que buscar los datos de estos y hacer una ingenieria inversa para detallar el funcionamiento de la misma, pero para que sea mas facil revisa el cable del puerto de comunicacion entre la tarjeta de mando y el variador de frecuencia, si este esta bueno teniendo continuidad, Ah en este cable hay una linea de color ***** que no se utliza esta solo conectado en uno de los estremos, si todo esto esta bien sustituye esta tarjeta por una nueva la misma esta averiada y si no tienes mucho conocimiento en electronica no la podras reparar o poco tiempo que es lo que sucede a mi, que tenga suerte.
Ramon

Hobart HL600... | 858 views | 0 helpful votes


No sir.

Hobart HL600... | 147 views | 0 helpful votes


error 99 stands for communication fault between timer board and the sr drive.there are 5 things that can cause this error.1.rs-485 cable disconnected or malfunction 2.1 con monitordisconnected or malfunction. 3.run/stop wiring disconnected or malfunction. 4.timer board malfunction. 5.sr drive malfunction. hope this helps, dont forget to vote, thanks, monomoy

Hobart HL600... | 1,182 views | 2 helpful votes


that fault is a b_gd.there are 10 things that can cause this.1.start sw.momentary contacts not closing. 2.stop sw. contacts open. 3.bowl guard sw. open or malfunction(b_gd)displayed on timer.4.contactor 1con malfunction.5.timerboard malfunction.6.wiring incorrect from sr drive to motor or 1con.7.sr drive malfunction 8.1 con monitor from control drive disconnected from contactor coil9.encoder malfunction 10.motor malfunction. hopefully just your bowl guard switch is no good. hope this helps, dont forget to vote, monomoy

Hobart HL600... | 695 views | 2 helpful votes

Not finding what you are looking for?
Hobart HL600 Legacy Stand Mixer Logo

68 questions posted

Ask a Question

Usually answered in minutes!

Top Hobart Food Mixers Experts

Pieter Vleeshouwers
Pieter Vleeshouwers

Level 3 Expert

2027 Answers

Marvin
Marvin

Level 3 Expert

85239 Answers

Lawrence Oravetz

Level 3 Expert

10548 Answers