1answer

My American Standard R120 shower valve has excellent pressure on the cold side, no pressure on the hot side.

Could be a chunk of scale in the valve. Need to turn off water supply and take valve apart. If nothing is found, turn water supply on to give line a 'quick' flush and turn back off. If this does not help, you probably have an obstruction somewhere in the hot supply line and a plumber may be needed unless you are handy. Good luck.
1/1/2014 3:55:49 AM • American... • 451 views • 0 helpful votes
0helpful
1answer

Overflow tube

If you manually pull up on the float of the fill valve will it then shut off? If it does, most likely your water pressure is too high, should be around 60 psi. More then 80 and it won't shut off. You may need to add a restrictor to the fill valve. Most fluid-master units come with one already installed, you could try one of them.
2/5/2014 3:52:19 AM • American... • 152 views • 0 helpful votes
0helpful
1answer

Toilet Tank overflow wasting water need manual.

Adjust the float so water level stops at 1/2" below top of overflow pipe.
1/7/2014 12:42:49 AM • American... • 133 views • 0 helpful votes
0helpful
1answer

Have an American standard whirlpool tub. the

This sounds like the air switch in the motor is not working properly. You will need to remove the pump from under the tub to access the air switch located in a housing on the motor.
Replacement Air Switch will cost you about $20US Parts Center
8/27/2013 2:39:02 PM • American... • 3,015 views • 0 helpful votes
0helpful
1answer

How to unfreeze toilet pipes in a mobile home

I live in a mobile home park and that is what i do as the park handyman. The fastest way... cut the pipe with a recipricating saw and remove a long section. Knock it to let all the ice slide out. bring it into a warm shop for a while if you have to or run warm water through it. place a micro furnace near the sewer and use a heatgun if more ice is at the other end. Once things are clear, use two 3 inch fernco adapters and clamp everything back together. (i always keep a couple on hand just in case this happens) Make sure the lean is perfectly angled with no place for water to sit or this is what happens.
11/30/2013 6:06:21 AM • American... • 132 views • 0 helpful votes
0helpful
1answer

Air switch doesn't return to top position

follow this steps and fix it. God bless you Clear a blocked water intake:
  1. Twist-off or unscrew the intake cover.
  2. Clean the intake cover with an old toothbrush and powdered laundry detergent. Rinse any soap residue from the cover before reinstalling.
  3. Replace the cover.
Replace a jet:
  1. Identify the damaged or inoperative jet and make sure it requires replacement.
  2. Follow the owner's manual instructions for removing the old jet. Some twist out by hand while others require a special wrench.
  3. Find an exact replacement jet (through a pool or spa supplier) and install the new jet.
11/23/2013 10:03:53 PM • American... • 92 views • 0 helpful votes
0helpful
1answer

I have a American Standard Corner Whirlpool Year

t sounds like you have a bad air switch located in your motor. The air switch is what the air hose connects to on the back of the motor or on the box on top of the motor. The other end of the air hose is connected to the air button on the lip of the tub. This is a latching air switch and when you push the air button it latches to send power to the motor. When the air button is pushed again it opens the latch in the air switch and stops power going to the motor shutting it off. US Parts Center
9/27/2013 1:26:47 AM • American... • 426 views • 0 helpful votes
0helpful
1answer

Bidet keeps running

If you've tried turning off both shutoffs underneath and water still runs, then the shutoffs are also likely worn out and need to be replaced. If there is no way to shut off from that point, then the only other option is to have somebody turn off all water in the house near your water meter or main water line. In many places, hardware stores will sell something called a "water shutoff key", but depending on your location, it may have a different local name. Once water is off to the whole house, turn the hot water on somewhere in the house to reduce pressure from your water heater before replacing your faucet and shutoff valves. It is a good idea to take one of your old water shutoffs with you to a hardware store to make sure the new one would fit propperly. If you know somebody who can take apart the faucets to check and replace just the washers, then it could be fixed with even less expense, if you would not rather replace the faucet with a new one that will last longer.
10/14/2013 7:29:18 PM • American... • 197 views • 0 helpful votes
0helpful
1answer

Air switch

Air Switch Repair It sounds like you have a bad air switch located in your motor. The air switch is what the air hose connects to on the back of the motor or on the box on top of the motor. The other end of the air hose is connected to the air button on the lip of the tub. This is a latching air switch and when you push the air button it latches to send power to the motor. When the air button is pushed again it opens the latch in the air switch and stops power going to the motor shutting it off. Search for TBS-339 Air Switch US Parts Center
9/27/2013 1:08:12 AM • American... • 263 views • 0 helpful votes
0helpful
1answer

Tub will not turn off

If your pump will not shut off when you push the button on the tub then you have a bad air switch in the motor. Rod US Parts Center
11/23/2013 2:59:48 AM • American... • 58 views • 0 helpful votes
0helpful
1answer

On and off switch

Try a bathroom supply shop or your place of purchase. Failing that try http://www.americanstandard-us.com/support/
11/9/2013 5:10:49 PM • American... • 79 views • 0 helpful votes
0helpful
1answer

I have a Cadet 3 toilet with a slow flow when

It could be a venting issue. Check the roof vent for the plumbing system. Perhaps clogged with leaves or other debris causing a blockage in the vent line. You can use a hose up to the roof and flush out the vent line. Another problem may be calcium buildup. CLR , a product available at most hardware and grocery stores will dissolve mineral buildups.
10/11/2013 3:18:35 PM • American... • 134 views • 0 helpful votes
0helpful
1answer

Bad control switch

What is the problem? How do you turn this tub on/off ?
11/9/2013 5:08:31 PM • American... • 54 views • 0 helpful votes
0helpful
1answer

Both sinks have fissures, small cracks, developing

Two things come to mind, The sinks were installed out of balance and way over tightened causing a constant stress on a warped surface, or a foreign object was left under lips of sinks. If they were purchased and installed at the same time you could have received damaged merchandise.
8/15/2013 5:40:18 AM • American... • 127 views • 0 helpful votes
0helpful
1answer

How to fix a toilet tank that won't flush unless you hold handle down for awhile.

Check to make sure the chain fromanagement the trip lever to the flapper does not have too much slack in it if there is shorten the chain so when the lever is down there is just a little slack in the chain. Hope this helps Bob
5/29/2013 5:25:53 PM • American... • 573 views • 0 helpful votes
0helpful
1answer

Water wont stop running

Water is either running (1) into the overflow tube or (2) out to the toilet under the flapper at the bottom of the tank. If (1) lower the ball or float. Done differently depending on model. If (2) replace the flapper with new flapper designed for your model. (Note: Raise manually the float valve and if water still runs out the little tube that goes into the overflow tube then fill valve is defective. Replace it.)
3/24/2013 3:38:10 PM • American... • 158 views • 0 helpful votes
1helpful
1answer

Eljer one-piece lowboy toilet - toilet seat cover screws could not be removed

You may have to use a really neat tool and that is aunt splitter. You can get it at O Reilly's auto store or any of those stores. That should remove it.
2/5/2013 8:12:45 PM • American... • 204 views • 1 helpful votes
0helpful
1answer

Why does my toilet suddenly fill the tank?

Usually seeping is from under the flapper. Replace flapper with one designed for that model. Avoid generic flappers.
11/17/2012 3:37:21 AM • American... • 209 views • 0 helpful votes
0helpful
1answer

Toilet tank fills randomly, why is this?

Flapper seal is damaged or worn out. Replace Flapper with one for your model.
11/17/2012 5:31:09 AM • American... • 126 views • 0 helpful votes
0helpful
1answer

Toilet takes a long time to fill up after flushing

Perhaps the shut off valve is not fully open, or constricted. Try opening and closing the shut off valve to loosen any sediment. Otherwise, replace shut off valve.
9/14/2012 7:59:57 PM • American... • 542 views • 0 helpful votes
Not finding what you are looking for?
American Standard 5 ft Sliding Shower Door Logo

9 questions posted

Ask a Question

Usually answered in minutes!

Top American Standard Home Experts

john h

Level 3 Expert

29494 Answers

Mike Cairns
Mike Cairns

Level 3 Expert

3054 Answers

deton8 von Splosion

Level 3 Expert

3342 Answers

Are you an American Standard Home Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

American Standard Home

  • American Standard Home

Most Popular Question

flair shower door runner

  • Home
Loading...