Leviton R01-PR180-1LI Decora 180 Degree PIR Motion Switch Ivory - Page 7 Questions & Answers
2 n2000 dimmers controlling lights
I am having the same trouble in my church with two nsi/leviton dimmers. Wide horizontal bar created on video screen during dimming. No bar at 100% or off, just anywhere in between.
12/12/2010 5:35:15 AM •
Leviton...
•
Answered
on Dec 12, 2010
Actually I have 6681, 600w; want to use to
The dimmer isn't a straight resistor, its an R-C timing circuit, and the caps within that circuit are going to mess up any resistance measurement you're trying to make. The R-C circuit is there as a timing mechanism to determinine the duty cycle on/off time of the dimmer. It is because of that, that I recommend you try to not use a light-dimmer for a soldering iron - the dimmers are not resistive rheostats, they're light switches (on and off @ 120-times a second). Depending upon the nature of the soldering iron, that may cause some harmful problems.
10/18/2010 4:51:10 PM •
Leviton...
•
Answered
on Oct 18, 2010
I have a Leviton 5634
Review old switches:
Two old switches > each has 2 wires
Old switch 1 > Red and White
Old switch 2 > Black and White
The same white wire connects to both switches, so effectively they count as 1 wire
This means you have 3 wires ... 1 White, 1 Red, 1 Black
Each switch controls a separate load (light, fan, motor)
New Leviton double-rocker switch:
-Leviton has 2 Brass-colored screws on one side, and these screws are connected together by a brass plate >> your Hot wire will connect to brass screw
-Leviton has 2 Silver-colored screws on other side, and neither of these screws are connected in any way >> the wires going to each load will connect on a different screw on this side of switch.
Hot wire: Each box in your house has exactly 1 hot wire that is connected back to breaker box. This is true for all boxes (excluding boxes that have a 3-way & 4-way switches).
We need to identify Hot wire.
-By code the Hot wire is black for identification purposes ... but your box sounds like maybe the Hot wire is White.
-If your Hot wire is white, that is NOT an immediate safety issue ... it will not cause a fire or malfunction ... it is a code violation ... because code requires things be uniform so next electrician knows what previous guy did. So some day, electrician working outside grabs wrong color wire, and wow. I say this so you know.
Moving on.
Identify Hot wire:
-Pull 3 wires up so they can be tested
-Turn on power
-Use ordinary tester, or old lamp with plug cut off and wires stripped back
-Tape tester lead to sticks so hands are away from voltage
-Power is on. Don't stand in water or touch metal pipes, and you're fine.
-You have 3 wires in box + ground wire
-Test all 3 wires to bare ground wire >> when tester lights up, that is Hot wire ... testing is complete
Connect wires to Leviton double-rocker:
-Power is OFF.
-You have 3 wires - 1 White, 1 Black, 1 Red >> one is Hot wire, the other two wires go to load
-Hot wire connects to Brass-colored screws on new Leviton.
-Brass colored screws are connected together by a brass plate so the Hot does not need to connect to both brass screws.
-The other two wires connect to Silver screws on other side of new Leviton switch
-One wire goes to each silver screw
-Connect bare ground wire to green screw.
-Push wires back into box. Use eraser end of pencil if needed.
-Make sure ground wire is back and away from screws on switch
-That's it.
9/30/2010 8:55:24 AM •
Leviton...
•
Answered
on Sep 30, 2010
Have a switch from ceiling light cat # 573, very
If there is an electrical specialty store in your area, i would remove the switch and take it there. They may be able to help in either replacing or rebuilding it. That sort of control is not difficult to recreate, but it is an uncommon feature. A good electronics tech can show you how and get you the parts to do it. i am NOT talking about Radio Shack. i mean a mom and pop shop that specializes in electrical and electronics.
i hope this helps
matthew
11/19/2009 6:15:26 PM •
Leviton...
•
Answered
on Nov 19, 2009
Dimmer turns on/off 3 spotlights but they wont dim
Questions to answer so I can answer/resolve your problem:
1) Is this a rotary style dimmer?
2) Is it a toggle or slider type?
3) Is this on a 3-way circuit (that has 2 or more switches that can turn the lights on or off)
4) Is this on a single switch circuit?
5) Is this a brand new dimmer switch?
6) Is this an old dimmer switch?
7) Are the light bulbs in the spots regular incandesant or halogen bulbs?
8) Are the light bulbs in the spots CFL (compact flouresent lamps)?
With this information, I can tell you what the problem is:
If you answer "YES" to #1, and or #6 then the dimmer is faulty and should be replaced.
If you answer "YES" to #8, then you have the wrong dimmer for the bulb type, as CFL's require a specific dimmer type in order to dim them.
Please provide some more info and maybe we can help you figure out what's wrong.
Hope you find this Very Helpful and best regards!
8/22/2009 4:39:28 AM •
Leviton...
•
Answered
on Aug 22, 2009
I am replacing a double switch which controlled
One side of the switch has Brass screws, and the other has nickle screws. there is usually a small brass bridge between the upper, and lower switch screws on the brass screw side. if you are feeding both from a common power source leave the little brass bridge in place, and screw on of the screws in all the way. Put the energised wire under the other brass screw. Bare copper wire goes to the green screw. The power will be transferred to the nickle screws through the corresponding switch. put the wire to the fan on one, and the light on the other. Presto.
8/17/2009 4:13:29 PM •
Leviton...
•
Answered
on Aug 17, 2009
I have installed a set of Vizia vz106-1l dimmer
not familier with this model but yes sounds like its wired incorrectly, usually on a 2 way switch you will only have 1 live comming in, it will feed common in, the bottom 2 will connect too the bottom 2 on the other switch in opposite order then the common on the other switch will fed the light.
8/15/2009 8:22:08 AM •
Leviton...
•
Answered
on Aug 15, 2009
On the combination Two Switches #5224 do I break
No need to break the tab... that' on the power IN side of the switch..
You only need one power in (in most cases).
The power outs are separated already.. one goes to your first load and the other will go to the second.
The white wires are your common and are hooked together with the other whites in the box... don't hook them to the switch.
Hope this get's ya all connected... let me know if you need more assistance.
K
6/19/2009 12:27:42 AM •
Leviton...
•
Answered
on Jun 19, 2009
My conlog meter is showing the rfcon error please what do I do
No connecting to your utilty company in South Africa. Just FYI, we are a North American site and my not always have the answer, in this case we do
Https://www.facebook.com/ConlogSolutions/posts/im-having-a-rf-con-error-cant-do-anything-on-the-gadget-please-help-on-how-to-re/962048393965724/
Quoting from link above: "
Conlog Hi Ola-daniels, Please see below steps to assist with RFCON error :
* Press the Back arrow on the keypad - this step is to refresh the UIU ( the device)
* Type # 75 # - this is to check the signal strength
If it does not go back to the normal display
*Type # 80 # - this is to refresh the meter
Then lastly you can repair the meter and the UIU by # 36 #
The above steps will work better if you are outside the house because the meters uses the radio frequency connection
The above error will occur in instances of bad weather conditions or if there is load shedding or power failure
If the problem persists after trying the above you may contact the municipality or the service provider."
SOLVED: How do I clear up the rf con error on my meter ...
https://www.fixya.com > ... > The
May 7, 2020 - How do I clear up the rf con error on my meter because I want to ... Https://www.facebook.com/ConlogSolutions/posts/im-having-a-rf-con-error- ... Hi Ola-daniels, Please see below steps to assist with RFCON error : ... shut down the energy alimentation for 2 minute ,but if the defect persist error it show again.
SOLVED: Pole meter conlog rf con meter keep on freezing ...
Jan. 10, 2017
Meter reading shows rF CON instead of units available - Fixya
Jun. 24, 2018
SOLVED: Good day my conlog ip54 elecricity meter showd ...
Oct. 6, 2018
SOLVED: Rf con error - Fixya
Jun. 20, 2020
More results from www.fixya.com
Please Help With My Conlog Prepaid Meter - Technology ...
https://www.nairaland.com > please-conlog-prepaid-meter
Aug. 6, 2020 - ystar: If the conlog meter is showing rf-Con, it means power supply doesn't reach the meter at all its either Loss of phase from the transformer or a loose contact ...
How Do I Load The Activation Token On My Conlog Prepaid ...
Mar. 17, 2020
I Need A Technician To Fix This... - Nairaland / General - Nigeria
Jul. 22, 2019
I Need Number Codes To Reset Memmcol Prepaid Meter ...
Jan. 11, 2019
More results from www.nairaland.com
Can i use this tester to check for any live wires. im installed a new light fixture on my porch from existing wiring but lights not tuning on
However, I can provide guidance on using a basic voltage tester to check for live wires when troubleshooting a light fixture installation.
Using a Voltage Tester:
Non-Contact Voltage Tester:
If you have a non-contact voltage tester, it's a handy tool for quickly identifying live wires without direct contact. Hold the tester close to the wire insulation or the terminal screws, and it should indicate the presence of voltage without making physical contact.
Contact Voltage Tester:
If you have a contact voltage tester, make sure it's designed for the voltage level you're working with (e.g., 120V for residential electrical systems).
Turn off the strength to the circuit on the circuit breaker or fuse box.
Safety First:
Always prioritize safety. Make sure the power is turned off before working on any electrical components.
Test the Tester:
Test the voltage tester on a known live circuit to ensure it's functioning properly.
Check the Wiring:
Once confirmed, turn off the power to the circuit you are working on.
Use the voltage tester to check each wire connected to the light fixture. Verify that there is voltage on the wires.
Neutral and Hot Wires:
Typically, a light fixture will have a hot wire (usually black) and a neutral wire (usually white). Make positive each wires are linked properly.
Ground Wire:
Check for a ground wire and ensure it's properly connected. Some light fixtures may have a green or bare copper wire for grounding.
Switch Position:
Ensure that the wall switch controlling the light fixture is in the ON position.
Bulb Check:
Confirm that the light bulbs in the fixture are working and properly installed.
Circuit Breaker Check:
Double-check the circuit breaker or fuse for the lighting circuit to make sure it hasn't tripped or blown.
I have a onan 4000 LP generator when I try to start it it starts and then goes dead?
Here are some common troubleshooting steps to help you identify and potentially resolve the problem:
- Fuel Supply:
- Check the LP (propane) fuel supply. Ensure that there is enough propane in the tank.
- Check for any obstructions or kinks in the fuel line.
- Air Intake and Exhaust:
- Make sure the air intake and exhaust are not blocked. Lack of proper ventilation can cause the generator to shut down.
- Choke Position:
- Check the position of the choke. If it's set to "Choke" for starting, make sure to gradually move it to the "Run" position once the generator has started.
- Fault Codes or Indicator Lights:
- Look for any fault codes or indicator lights on the generator control panel. These can provide clues about specific issues.
- Oil Level:
- Check the oil level in the generator. Some generators have a safety feature that shuts them down if the oil level is too low.
- Spark Plug:
- Inspect the spark plug for fouling or damage. If needed, clean or replace the spark plug.
- Fuel System Issues:
- Inspect the fuel system for any leaks or issues. LP generators may have a fuel filter that needs to be checked and, if necessary, replaced.
- Carburetor:
- The carburetor may need cleaning or adjustment. If it's clogged, it can lead to stalling issues.
- Battery Voltage:
- Ensure that the generator's battery has sufficient voltage. A weak or dead battery can affect the starting process.
- Generator Load:
- If the generator is under a heavy load, it may shut down. Try starting it without any load and then gradually add loads.