0helpful
1answer

Want to see a manual for model 6G40-36F1

I can get the pilot lit but when I turn the water heater on it blows out everything it is a Richmond water heater serial number 6G 40-36f 1
3/4/2023 4:17:19 PM • Water Heaters • Answered on Mar 04, 2023
0helpful
1answer

Paloma tankless displays error code C7 38. already removed remote and tried it still shuts off after a couple of minutes. any help?

The issue of the Paloma tankless water heater displaying error code C7 38 may be caused by several factors, including a problem with the thermistor or temperature sensor, an issue with the gas valve or gas pressure, or a malfunction with the control unit or circuit board. To troubleshoot, try checking the thermistor and temperature sensor, and verifying the proper functioning of the gas valve and gas pressure. If the problem persists, consider seeking professional repair or service.
1/29/2023 11:20:20 AM • Water Heaters • Answered on Jan 29, 2023
0helpful
2answers

Honeywell WV8840B1109 temp control valve on water

You can reset the code by turning Gage all the way up highest setting count to ten turn it to hot could to ten then turn to pilot count to ten and then turn it to desired temp burner should come on. Saves lots of money and time
1/28/2023 9:18:38 PM • Water Heaters • Answered on Jan 28, 2023
0helpful
1answer

Is the power button on my xtreme electric heater supposed to keep blinking.

The circuit is about to overload and the break could turn off due from too much electricity being used.The circuit is overloading or there is a problem with the panel needs to be replaced or the wires for your heater could be frayed or have tears in them and need to be replaced.
12/18/2022 8:08:56 AM • Water Heaters • Answered on Dec 18, 2022
0helpful
6answers

Need a manual for drayton tempus 3 heating control

I've ended up with a Drayton Tempus 3 when I bought my house, and I think this is how it works. It allows you to set 2 Timers (I'll call them timer 1 and timer 2) so that you can control Hot Water or Heating On/Off times twice a day. The unit has 6 buttons - 2 for Adjustment, 2 for Hot Water and 2 for Heating. The 2 Adjustment buttons allow you adjust the Clock Time, or allow you to adjust Timer 1 and/or Timer 2. NOTE: Timer 1 is the time refered to on the Heating / Hot Water Select buttons if you press "Once". If you select "Twice" on these the both Timer 1 and Timer 2 are taken into account. For example if you want Hot Water to come on Once between 8pm -10pm, but you want Heating to come on Twice between 6am - 7am, and 8pm -10pm, you have to do the following: Set Timer 1 to 8pm - 10pm, and set Timer 2 to 6am -7pm. Then select Once for Hot Water, and select Twice for Heating. Hope this helps.
12/13/2022 9:55:31 AM • Water Heaters • Answered on Dec 13, 2022
0helpful
2answers

Electric Water Heater blows fuse, but only every few years

Your residential water heater is not 9000 watts. Or it would blow the fuse every day and melt the wire. Instead, you have dual-element non-simultaneous 4500 watt water heater.http://waterhatertimer.org/How-it-works.htmlhttp://waterheatertimer.org/Figure-Volts-Amps-Watts-for-water-heater.htmlLook at label for 'total connected watts'http://waterheatertimer.org/images/Whirlpool-energy-smart-watt-rating-IMG_2600.jpg25 amp breaker or fuse and 10 gauge wire is minimum acceptable for 4500 watt water heater.http://waterheatertimer.org/Color-code-wire.htmlTroubleshoot blowing breaker or fuse:http://waterheatertimer.org/How-to-troubleshoot-electric-problems-with-water-heater.html#trip-breakerWhy does it blow fuse once each year?? I don't know.Fuses and breakers trip when overheating occurs on wire.Each fuse or breaker is rated for heat, and over time, it will get hot and then cool and then get hot again ... this action weakens fuse or breaker.To solve problem: install 3500 watt elements (and clean sediment out of tank). Wire will run cooler, and fuse will last longer. Whole fuse box will demand less power, and run cooler, and will last longer as a result. So there is less stress on electric service panel.http://waterheatertimer.org/How-to-replace-water-heater-element.html3500 watt element will heat water to same temperature, but takes longer. For example: 4500 watt heats 21 gallons per hour, while 3500 watt heats 17 gallons per hour. If you need further help, I’m available over the phone at https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
11/25/2022 9:28:16 AM • Water Heaters • Answered on Nov 25, 2022
0helpful
1answer

Mainstay 1500 watt model FP404RN heater won't start

https://www.electricfireplacesdirect.com/blogs/fireside-blog/7-reasons-your-electric-fireplace-may-not-be-working
11/21/2022 12:57:15 PM • Water Heaters • Answered on Nov 21, 2022
0helpful
1answer

Pipe repair and not only in Toronto

Hi. Very cool requirement you actually have. There is nothing that the experts at this plumbing site in Canada can't do . They have been providing friendly service to commercial customers in Canada for over 20 years. I hope you find my recommendation helpful.
11/20/2022 5:06:29 AM • Water Heaters • Answered on Nov 20, 2022
0answers
0helpful
1answer

Why is the gas not going to the burner?

'make model (what it is)' in all question please Rick. All of the gas passageways in a fridge are very small. If you removed the gas valve and associated pipes, it takes a long time for the gas to bleed through and get from the gas line to the pilot light and that is needed to heat the thermocouple and allow the gas valve to open. It should also be mentioned that all work on Gas appliances should be undertaken by a qualified and registered gas technician.
11/3/2022 2:25:20 AM • Water Heaters • Answered on Nov 03, 2022
0helpful
1answer
0helpful
3answers

My pilot light control switch will not return to Off or pilot it is stuck in the On position.

Question edited for funky spelling of 'pilot', (piolt light)..You posted to the Cars and Trucks category, what year make and model is it? :>DThis sounds like some type of gas appliance, stove, fire or central heating furnace? It is gas and can only be worked on by a registered gas service technician.'make model (what is is)' in all question of this type please.'year make model' in all vehicle questions please.
10/21/2022 5:55:46 AM • Water Heaters • Answered on Oct 21, 2022
0helpful
2answers

I have a GSW Superflue power vented electronic ignition. It lights and fires up for 15sec then goes out. Keeps doing this. When I open the two front covers the flame stays lit and strong. As close

definite air intake problem . check the filter at the bottom of the unit. and keep the area around the unit clear and clean to prevent recurrence
9/21/2022 1:06:51 AM • Water Heaters • Answered on Sep 21, 2022
0helpful
2answers

Eemax SPEX3512 FlowCo 3.5 Kilowatt tankless heater alarm buzzing?

Contact their Support direct. It may be low water pressure. https://www.eemax.com/products/eemax-flowco/spex3512 ..
9/6/2022 3:41:05 AM • Water Heaters • Answered on Sep 06, 2022
0helpful
1answer

How old is my rheem stardard water heater model 666h-52d

That model is from 1972 products line.
8/18/2022 6:08:10 AM • Water Heaters • Answered on Aug 18, 2022
0helpful
1answer

Morco D61B Water Heater. The pilot light is boiling the water??

It would be. The flue and the cover needs to be attached to reduce air flow and direct it up the flue. Or the pilot light needs the flame turning down. It is a gas appliance and needs to be serviced by a gas certified engineer.Owner manual and technical instructions.https://www.freeboilermanuals.com/assets/pdf/Morco/D61B-good.pdf..
7/19/2022 3:05:26 PM • Water Heaters • Answered on Jul 19, 2022
0helpful
2answers

Rheem RTEX-27 Tankless Water Heater. Can't find reset button on my Raheem tankless retry 27

Question edited for clarity. Looks like you encountered autocorrect The manual is here. It doesn't mention a reset button.

Rheem RETEX-27 instruction manual and user guide

https://mans.io > Rheem > Tankless Electric Water Heaters Rheem RETEX-27 Performance 27 kw Self-Modulating 5.27 GPM Tankless Electric Water Heater download pdf instruction manual and user guide. But this says it does, or may have? Where Is the Reset Button on a Rheem Hot Water Heater? On Rheem water heaters, the reset button is usually a red button located near the thermostat, at the middle of the limit switch. To access it, you will need to remove the metal panel on the unit. The red button is behind the insulation.

How to Reset Rheem Tankless Water Heater - Quick Fix

7/16/2022 6:29:56 AM • Water Heaters • Answered on Jul 16, 2022
0helpful
1answer

Wat is the error code EFDW how to find

Quoting more information like make and model of heater would help you get an answer.
6/18/2022 6:57:29 AM • Water Heaters • Answered on Jun 18, 2022
0helpful
1answer

Is AGA somehow connected to combi boiler

Some combi boilers have a 'Keep Warm' function. Check to see if your combi has this feature. This is a function where the system preheats an amount of hot water to provide instant hot water when you turn on the tap/faucet. To do this the combi will start up when it detects the stored water is below a certain temperature to reheat it ready for use. This can be turned off if you prefer not to use it.
5/25/2022 5:49:28 PM • Water Heaters • Answered on May 25, 2022
Not finding what you are looking for?
Suburban Mfg Co Water Heater Direct Spark Ignition 6 Gallon Logo

2 questions posted

Ask a Question

Usually answered in minutes!

Top Suburban Mfg Co Water Heaters Experts

Brad Brown

Level 3 Expert

19187 Answers

Paul Carew

Level 3 Expert

3808 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66957 Answers

Are you a Suburban Mfg Co Water Heater Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

View Most Popular

Suburban Mfg Co Water Heaters

  • Suburban Mfg Co Water Heaters

Most Popular Question

hot water heater starts about 5 10 sec

  • Water Heaters
Loading...