I have a protech 1220I THAT IS IN NEED OF REPAIR
Automatic battery chargers have complex circuitry that is difficult to test especially when designed and built in a compact package and repairs are best entrusted to someone geared to such work which is outside the scope of general electronics.
On the plus side, as long as the intelligent circuitry is protected against mains borne surges and spikes the automatic charger is somewhat self-protecting against over stress and will tend not to even attempt to charge a defective battery, a sulphated or overly discharged battery.
I suggest you first check the battery or batteries to ensure they are healthy and have some charge so the charger can "see" them before condemning the charger and also check the connections to the battery that must be virtually perfect...
Satchwell geyser thermostat
NO HOT WATER
- If the tester indicates there is power to the terminals and the water in the geyser is cold, then the element is faulty. ( ...
- If the tester indicates there is no power to the terminals and the water is cold, then the thermostat is faulty.
https://www.youtube.com/watch?v=qCXmyhEY_k4
Fv sense problem code
Type of gas control valve is not known.Brand of water heater is not known.FV event can mean that air intake is clogged, gas control valve has gone bad, or FV system has tripped, or TCO has tripped ... or all of above.Clean air intake, download manual from manufacturer and read troubleshoot section, call manufacturer.Copy following links for troubleshoot resourceshttp://waterheatertimer.org/How-to-repair-Rheem-FVIR.htmlhttp://waterheatertimer.org/How-to-troubleshoot-gas-water-heater.htmlhttp://www.thetankatwaterheaterrescue.com/forums/forum3/ If you need further help, I’m available over the phone at
https://www.6ya.com/expert/gene_9f0ef4df2f9897e7
What is an E2 fault in heater?
A typical answer for this is to initially unplug the water warmer from its electrical stockpile. Next, evacuate the spread by unscrewing the four fastens that hold it place. The indoor mounted 45HI models have a strip link interfacing the showcase to the PC board. It would be ideal if you be cautious as to not harm this wire. You should disengage it utilizing the dark connector found 6 crawls from the showcase itself. Once inside the water radiator, you will see the PC board situated on the left-hand side, at the base corner of your warmer. Next, expel the two screws on the essence of the PC board at the base. Next, detach and reconnect the majority of the wires each in turn, which is associated with the PC board to confirm that everything is situated appropriately. You would then be able to sink the PC board back spot, supplant the spread, plug up the power supply, and endeavor to run the water radiator as typical. For More Information You Can Visit https://www.indiapropertyclinic.com/services/water-heater-install-repair