Rheem 40 Gallon FVR NATGAS Low WATER HEATER 6YR 22V40SF - Page 7 - Answered Questions & Fixed issues

0helpful
1answer

Damper-bottom of hot water heater broke when changed themocouple

U cannot put it back together it is a fail safe if the unit over heats from a plugged inlet the spring loaded damper is released by one of two way solder retainer melts or vial melts either way the the unit is bad contact Rheem with the 1800 number on the tank and depending on the age they will replace the tank. You will have to uninstall it take it back then install the new tank all not covered by them or if you can't do this a local plumber or hvac company can do it for u
4/2/2010 4:08:07 AM • Rheem 40 Gallon... • Answered on Apr 02, 2010 • 103 views
0helpful
1answer

Superflue heater will not light

The self igniter, or thermal couple is bad.
3/28/2010 1:09:41 AM • Rheem 40 Gallon... • Answered on Mar 28, 2010 • 1,175 views
0helpful
1answer

We don't have hot water

at the bottom of your tank where the removeable plate (access) is, remove it, look inside and you'll see the thermocouple could be bad.. also see if the tank is lit, if it is, then it's a good bet that the thermocouple is out... it is real easy to remove
3/22/2010 6:26:58 AM • Rheem 40 Gallon... • Answered on Mar 22, 2010 • 86 views
0helpful
1answer

Relief valve on rheem 41v40 s-40f leaks

Relief (pop-off) valves can be replaced. Make sure to get the right one. They unscrew from the unit. They are generally screwed in very tight, you may have to get a good size wrench or pipe wrench to loosen it; especially if it is more than a few years old.
3/19/2010 1:30:14 AM • Rheem 40 Gallon... • Answered on Mar 19, 2010 • 735 views
0helpful
1answer

Walls shake when burner comes on

Your heater is in need of maintenance by a qualified technician.

Don't try to fix it yourself as gas(?) can be dangerous if the air/gas ratio is wrong (i.e. explosion!).

Turn off your heater and do not use it until it has been repaired!
3/18/2010 3:14:09 PM • Rheem 40 Gallon... • Answered on Mar 18, 2010 • 187 views
0helpful
2answers

I replaced the pressure relief valve but still

Might need to install/ replace the pressure reducing valve between the house and water supply.
3/17/2010 12:23:56 PM • Rheem 40 Gallon... • Answered on Mar 17, 2010 • 114 views
0helpful
1answer

Pilot light won't stay lit in gas water heater

If this heater was manufactured after 2003 it has a FVIR filter. It is usually located on the bottom of the heater and this is where it draws air into the combustion chamber. Check to see if it is clogged with dust or lint.
because the heater probably has a sensor, it is not getting enough air and shutting off. hope this helped.
3/17/2010 7:11:08 AM • Rheem 40 Gallon... • Answered on Mar 17, 2010 • 672 views
0helpful
1answer

Basement flooded;Water Heater insulation is a

tank looks to be leaking and getting the insualtion and floor wet .. so replace water heater?? Once the tank is leaking there is no repairing it..
3/16/2010 7:06:56 PM • Rheem 40 Gallon... • Answered on Mar 16, 2010 • 277 views
0helpful
1answer

Water is running out of the vale outside

Your temp and pressure valve is leaking, one of two problems is causing this. Either you need to install/ replace the pressure reducing valve between your house and the city water main(well), or you need to check the thermostat to be sure it is not overheating. Whatever you do DO NOT plug, cap, or block the t&p valve ever. Doing this is a bad idea, and could be fatal.
3/16/2010 1:50:15 AM • Rheem 40 Gallon... • Answered on Mar 16, 2010 • 93 views
0helpful
1answer

I have a rheem fury model 22-40 thats gushing

leaking tank, probably rusted at weld. replacement is the only sure cure.
3/10/2010 3:33:13 AM • Rheem 40 Gallon... • Answered on Mar 10, 2010 • 502 views
0helpful
1answer

Rheem model #GP40T6PF00 lp hot water heater Will

sounds like one of the saftey relays might be going bad. or the ingniter might be cracked or need cleaning
3/8/2010 6:26:13 PM • Rheem 40 Gallon... • Answered on Mar 08, 2010 • 664 views
0helpful
1answer

My rheem 22v50 wh is not producing hot water

Check thermostat, check power is on,
2/27/2010 9:09:40 AM • Rheem 40 Gallon... • Answered on Feb 27, 2010 • 107 views
0helpful
1answer

How do I light my Rheem water heater if my peizo

Remove the burner access cover under the control valve. Press the pilot light button (gas control) and hold it down. At the same time, light the pilot. Continue to hold the lighting button for a few seconds until the thermocouple heats up. Release the button. Twist the gas control knob to the ON position, and the burner should fire up after a few seconds. Replace the access cover. Good luck.
2/23/2010 4:10:10 AM • Rheem 40 Gallon... • Answered on Feb 23, 2010 • 287 views
0helpful
1answer

No hot water pressure

There are heat sync balls in the nipples of your cold and hot water lines on your hot water tank. Cut the water lines and remove these balls as sometimes they come loose and float to the point where your water line connections to the tank are causing the pressure to drop when your tap is turned on
2/19/2010 5:21:41 PM • Rheem 40 Gallon... • Answered on Feb 19, 2010 • 150 views
0helpful
1answer

Heat is on water is going in cold but not coming

Your gas valve may be faulty and need replacing as it is not sensing the change in water temperature in your hot water tank,
2/19/2010 5:19:16 PM • Rheem 40 Gallon... • Answered on Feb 19, 2010 • 59 views
0helpful
1answer

Does the 22v40sf have an thermal efficiency rating

unfortunately it does not. All natural air drafted hot water tanks have an AFUE rating of only 80%
2/18/2010 11:36:55 PM • Rheem 40 Gallon... • Answered on Feb 18, 2010 • 122 views
0helpful
1answer

Model 22V40F1 40-gals unit. Pilot lights up OK but won't stay lit

change the thermcouple
2/17/2010 4:58:28 AM • Rheem 40 Gallon... • Answered on Feb 17, 2010 • 865 views
0helpful
1answer

Rheem model 41vrp40n power vent water heater won't

"Pres sw open" means there is insufficient air flow. either the vent if blocked, or the blower turns too slow/ or died.
2/12/2010 7:06:12 PM • Rheem 40 Gallon... • Answered on Feb 12, 2010 • 2,438 views
0helpful
1answer

I have a Rheem 21VP40E Power Vent NatGas water

As long as the tank is not leaking. Go to Rheems website, and look up your model.
As with any large home appliance I would recommend a plumber or HVAC professional licensed by your state to perform the repairs.
I am pretty sure the part you need will be the gas valve contoller.
Please elt me know what you find.
2/10/2010 3:47:46 AM • Rheem 40 Gallon... • Answered on Feb 10, 2010 • 466 views
0helpful
1answer

The piolet light will not light. If I turn the

You may have a plugged orifice in the pilot tube assy. If you have any way of getting to the orifice with compressed air, and blow back, it may dislodge it, if it is plugged. If possible, carefully remove pilot tube at valve end first, so that if it is debris in there, it blows clean of the tube, so it won't clog again. Otherwise you'll have to remove complete assy. Another thing to try as well, is to shut valve off, loosen fitting at valve for pilot tube, AND MAKING SURE NO FLAME OR SPARK ANYWHERE IN THE AREA, take a spray bottle with dish soap and water mixed (bubble tester) and then spray at pilot fitting when it is loose, and push pilot, to see if any bubbles appear, indicating gas flow. If no flow there, then I'd get a new gas valve.
1/26/2010 1:13:00 AM • Rheem 40 Gallon... • Answered on Jan 26, 2010 • 371 views
Not finding what you are looking for?
Rheem 40 Gallon FVR NATGAS Low WATER HEATER 6YR 22V40SF Logo

264 questions posted

Ask a Question

Usually answered in minutes!

Top Rheem Water Heaters Experts

Mike Cairns
Mike Cairns

Level 3 Expert

3054 Answers

Brad Brown

Level 3 Expert

19187 Answers

Sean Wright
Sean Wright

Level 3 Expert

2045 Answers

Are you a Rheem Water Heater Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...