LG LS-L1210CL Mini Split Air Conditioner "air conditioner pcb" Questions

Ad

Question about Frigidaire Heating & Cooling

1 Answer

...Air Conditioner. Within the last 60 days I have personally experienced the exact same symtom. I replaced the PCB transformer and 1 diode on the main PCB of the air-conditioner and my AC unit is ...

Ad

Question about LG Heating & Cooling

1 Answer

conditioner is death.The power is coming,fuse on the PCB is OK? Check power to transformer (220volts---24/12volts Dc) which leads to function PCB. If 24 or 12 dc is o.k, then you have replace PCB only

Ad

Question about Carrier Heating & Cooling

1 Answer

My screen on the air conditioner control is blank and nothing is working .... Is there a way I can completely reset the unit?? Check power supply is going to PCB. If yes, repair or replace PCB

Question about LG Heating & Cooling

1 Answer

air conditioner shuts off model S12AHN turns on fine ... runs for a minute and switches off displaying the code C5 or CS on the units display panel. Any ideas?? C5 Communication Error • Wrong or ...

Question about LG Heating & Cooling

1 Answer

Blower won't work and not cold Check power to PCB and also power to blower motor. If power not to blower, then replace PCB. If power to PCB check room sensor and coil sensor for continuity. If no ...

Question about Heating & Cooling

1 Answer

...air conditioner we are replace the indoor pcb then next it gone out door pcb,next we are replaced outdoor pcb also then compressor not working oftre last we are replaced compressor then it will be ...

Question about Samsung Heating & Cooling

2 Answers

...due to sensor short. After replacing sensor it will show only A! or sometimes no error. If it shows A1, you have to repair/replace PCB. Helpful? my air condition needs to be reset how do I go about ...

Question about Samsung Heating & Cooling

1 Answer

Aqv24jax. Has a code flash light i-trip error/pcf over current what does it mean and how can I fix it? Indoor PCB faulty. Check for loose connection and rectify. If not replace PCB.

Question about LG Heating & Cooling

1 Answer

lg split system ch 46 error? help!!! Ch-46Outdoor unit suction sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°C. If OK replace PCB, if not replace

Question about Samsung Heating & Cooling

1 Answer

error message CH47 Compressor discharge sensor fault. Disconnect from PCB measure resistance. 237 kOhm at 20°C and 168 kOhm at 30°C. If OK replace PCB, if not replace sensor. Thanks, helpful

Not finding what you are looking for?
LG LS-L1210CL Mini Split Air Conditioner Logo

342 questions posted

Ask a Question

Usually answered in minutes!

Top LG Heating & Cooling Experts

Marvin
Marvin

Level 3 Expert

85239 Answers

Steve Oakes
Steve Oakes

Level 2 Expert

234 Answers

Muntejaya Ginting
Muntejaya Ginting

Level 3 Expert

10422 Answers

Are you a LG Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...