...water pump. Then start the unit and watch the low pressure gauge to see at what pressure the harvest starts. With R-404A cut in pressure should be around 34psi but depending on the model some units ...
Question about Ice Kitchen Appliances - Others
...water pump. Then start the unit and watch the low pressure gauge to see at what pressure the harvest starts. an ICEU150 with R-404A should cut in at 44psi. Once that is set plug the water pump in ...
Question about Ice Kitchen Appliances - Others
...water pump. Then start the unit and watch the low pressure gauge to see at what pressure the harvest starts. an ICEU220 with R-404A should cut in at 45psi. Once that is set plug the water pump in ...