...main charger installed securely?(2) Check if the spring of high-voltage supply contact point is deformed.(3) Check if the charger wire is broken or the main charger grid is deformed.(4) Check if any ...
Question about Toshiba Office Equipment & Supplies
...main charger installed securely? (2) Check if the spring of high-voltage supply contact point is deformed. (3) Check if the charger wire is broken or the main charger grid is deformed. (4) Check if ...
paper coming out black The main charger is faulty. clean main charger if not working replace the main charger.
...main charger is detected. 1. Is the main charger installed securely? 2. Check if the spring of high-voltage supply contact point is deformed. 3. Check if the needle electrode is broken or the main ...
Question about Toshiba Office Equipment & Supplies
...main charger Once u open the front cover, u can see 4 process units(CYMK). There is a main charger cleaner with green color knob on each process units.U just need to push the cleaner unit in and out ...
...main charger or LSU has stuck. Check the main chargers and the LSUs if their gears rotate properly or they are stuck somewhere. Otherwise, the motor that drives the cleaners is defective. You can ...
Question about Toshiba Office Equipment & Supplies
...main charger drum corana wire all catect U need to check or replace below parts: 1. Main Charger 2. T/S block 3. Terminal under T/S block ( with 2 springs) After changing above still cannot solve the ...
Question about Toshiba Office Equipment & Supplies
...main charger bias value is changed. Is the connector of the surface potential sensor connected properly? Is the main charger grid/wire attached poorly? Is the main charger attached poorly? Are leaks ...
...wire at the side door is broken or main charger grid is deformed. & if any foreign matters are on the charger wire or main charger grid. Need to check the main charger unit for each PU.... ...
Question about Toshiba Office Equipment & Supplies
main charger is detected. [C970] High-voltage transformer abnormality (1) Is the main charger installed securely? (2) Check if the spring of high-voltage supply contact point is deformed. (3) Check if