Desa International RH125AT Utility Heater "reddy runs 10 seconds" Questions

Ad

Question about Reddy Heating & Cooling

1 Answer

...Reddy will start no problem, run for 10-15 seconds and just shut off. I blew it out with a compressor and replaced the filter but it still won't run for more than 10-15 seconds. Any ideas are welcome ...

Ad

Question about Reddy Heating & Cooling

1 Answer

...reddy heater model 55000 that only works with cover off. with cover on runs 10 seconds shuts off. any help will be appreciated Hi, Here are a couple of tips that I wrote that tell you how to ...

Ad

Question about Reddy Heating & Cooling

1 Answer

...reddy heater. To start the heater, you plug it in, hold down the adjustible igniter button until unit lights,then hold for about 30 seconds and unit should continue to run. I ran this unit yesterday ...

Question about Desa International Heating & Cooling

1 Answer

...runs for 10-15 seconds then shuts off... has new fuel new fuel filter. what is causing this ? Hi, Here are a couple of tips that I wrote that tell you how to troubleshoot a Torpedo or Reddy heater... ...

Question about Reddy Heating & Cooling

1 Answer

runs for about 5 seconds and then quits. There is an adjustment screw on the back and I have gotten the heater to run up to 10 seconds and then when it tries to run at full force it quits again. Spark

Question about Reddy Heating & Cooling

1 Answer

...10 SECONDS AND IT RUNS FOR ABOUT 5 SECONDS. I TRIED NEW FUEL AND STILL DOES IT. CAN YOU HELP ME? check the filter cover for a small crack.most of the time this is overlooked.and people will just buy ...

Question about Reddy Heating & Cooling

1 Answer

remington 60 kerosene heater powers on and motor begins to run and can see fuel being delivered and ignitor heating up. runs for 5-10 seconds and shuts off Check your in tank fuel filter

Reddy-Heater will start then run about 10 seconds then stop. heater is app.2 yrs old. The heater has a photocell that has to see the correct flame or it will cause the heater to turn the unit off.I ...

Question about Dayton Heating & Cooling

1 Answer

...runs about 1 second, each time. After we unplugged it and waited 10 seconds for it to reset, we tried again unsuccessfully several more times. Each time the start-up was weaker. What's up with this ...

Question about Desa International Heating & Cooling

1 Answer

...runs for 10 seconds and then kicks the relay/circuit breaker on the unit. If i wait 5 seconds, it starts for 5 seconds and then kicks the breaker again. The air pressure is exactly 5lbs which is what ...

Not finding what you are looking for?
Desa International RH125AT Utility Heater Logo

24 questions posted

Ask a Question

Usually answered in minutes!

Top Desa International Heating & Cooling Experts

Paul Carew

Level 3 Expert

3808 Answers

Ronny Bennett Sr.
Ronny Bennett Sr.

Level 3 Expert

6988 Answers

john h

Level 3 Expert

29494 Answers

Are you a Desa International Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...