MR. Heater Portable Buddy model MH9B I have 2 Mr. Heater and both have the same symptom's. The pilot will lite, and as soon as i switch to the low setting ( 5000 BTU setting) the flame shuts off. I ...

Ad

Question about Reddy Heating & Cooling

1 Answer

won't stay running I can only keep it running with the cover off is this kerosene or propane. if kerosene, two types of ignition is used. a spark plug or a hot surface ignitor. the kero unit uses a ...

Ad

Question about Blue Rhino Heating & Cooling

1 Answer

...surface, if the whole thinfs one temp it drops out electrically(makes 30 millivolts) and the electromagnetically operated pilot safety valve closes, thus stopping the main burners operatin as ...

Question about Uniflame Heating & Cooling

4 Answers

Pilot light lit but no heat When trying to fire up my patio heater the pilot light lights but goes out when trying to turn gas supply knob to either high or low heat. Is there a way to find out if the

Question about Heating & Cooling

2 Answers

Comfort Glow Vent-free Gas Heater CGN18B I have a Comfort Glow Vent-free Gas Heater model number CGN18B. The pilot light will come on when i set the dial to "pilot". However when i turn it "high" the ...

when letting out the button on - on- pilot goes When letting out the button on - on- pilot goes off . What should I replace thermocoupler or the generator? Yes the thermocouple is the most likly cause

Question about Reddy Heating & Cooling

1 Answer

reddy heater R55tb it will fire up then quit what is pictured is a propane heater. two problem areas come to mind. one) the hi limit cutout, and two) the flame sensor. the hi limit is a normally ...

Question about Uniflame Heating & Cooling

1 Answer

problem getting patio heater to light i have an all pro outdoor patio heater - the pilot light lights but doesn't stay lite - i have a full tank of propane and have bled the air - can you give me a ...

Question about Reddy Heating & Cooling

1 Answer

wont run I have a small propane reddy heater that will start fine but when i let go of the igniter the flame goes out. They suggest that u hold the igniter in for 15 sec. the heater will not run even ...

...electromagnetic lock which keeps the gas valve open when the flame is burning. When the knob or shaft isn't pushing down enough, it doesn't keep the gas valve locked and the flame will go out as soon ...

Not finding what you are looking for?
Uniflame 200209 Open Flame Patio Heater Logo

57 questions posted

Ask a Question

Usually answered in minutes!

Top Uniflame Heating & Cooling Experts

Paul Carew

Level 3 Expert

3808 Answers

john h

Level 3 Expert

29494 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you an Uniflame Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...