Fedders A6X05F2D Air Conditioner "fan compressor not working" Questions

Ad

...compressor fan does not My heat pump is 4 years old. 18 months ago the fan on the compressor stopped working. After replacing a capacitor the fan worked fine. Well the fan has stopped working again. ...

Ad

fan on the compressor and on the evaporator). Sometime compressor starts before fans or continues to work several minutes when both fans turned off (they are both controlled by thermostat accordantly)

Ad

...fan and the compressor. The capacitor has three terminals. 1. common 2. fan = fan 3. Herm = compressor This is a common problem; The outdoor fan (condenser fan) runs, but not the compressor (you have ...

Question about Ruud Heating & Cooling

2 Answers

compressor and the fan motor) ,but if the fan doesn't start, you need to replace the fan motor. The system will not come on, the fan, heater, AC. It was working and we were away for a week and when we

...does not work. I am only getting hot air from the unit. The fan works the compressor does not. Is there a reset button Sounds like the compressor is hung up try using a hardstart to free it ...

Question about Ruud Heating & Cooling

1 Answer

compressor if the fan is not repaired, Ruud used a 3uf capacitor rating for the outdoor fan motor, if the motor has been changed make sure the proper capacitor is also changed for the new motor rating

...fan is working but external compressor is not coming on Inside fan is coming on but no cold air. The external compressor is not coming on at all does outside fan run? could be capacitor, compressor, ...

Question about Dometic Heating & Cooling

2 Answers

fan stops and the compressor freezes up. What happens when started in just fan mode? Sounds like relay stuck. I have the same issue.....the compressor come on any time power is provided to the unit...

Question about Haier Heating & Cooling

1 Answer

...units... #1- Sounds like compressor trys to start but does not. #2-Compressor runs but the exaust fan never starts. #1 Compressor fault, may be capacitor relay. #2 no gas or fan faulty (not

Question about Heating & Cooling

1 Answer

...compressor ran and the fan but it did not seem to be cold. This unit is brand new. the compressor got noisier be cause the head preasure was going up putting a strain on the compressor check all your ...

Not finding what you are looking for?
Fedders A6X05F2D Air Conditioner Logo

36 questions posted

Ask a Question

Usually answered in minutes!

Top Fedders Heating & Cooling Experts

Ronny Bennett Sr.
Ronny Bennett Sr.

Level 3 Expert

6988 Answers

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

Mike Cairns
Mike Cairns

Level 3 Expert

3054 Answers

Are you a Fedders Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...