error 06 problem problem 06 error The capstan motor has stopped functioning.Needs to be replaced.
E04 message At a certain point in playback, the picture stops and I get a flashing E04 message. Also, when I was recording on the same tape the other day, I got the same message. Hmmm, I am going to ...
...code E04. WHAT can i do to correct this error? 1. The drum cannot be started or drum rotation is stopped because tape transport load is too high. 1) Tape tension is extremely high. 2) The tape is ...
error is defined as [E04], and the mechanism mode is shifted to STOP with the pinch roller set off 1. The drum cannot be started or drum rotation is stopped because tape transport load is too high. 1)
...error code E01 means Mechanism has not fully loaded up to the stop position E06 meansTape drive motor is not rotating or stalled. Thses two faults indicate a tape jam. please remove the cassette and ...
error is defined as [E04], and the mechanism mode is shifted to STOP with the pinch roller set off. 1. The drum cannot be started or drum rotation is stopped because tape transport load is too high. 1
...this 2 or 3 times) this way i have solve the E04 Error, now i can record and play with my cam. I stopped the input( Get of the battery)several times when the dv window was open Afther CA 10 times ...
error is defined as [E04], and the mechanism mode is shifted to STOP with the pinch roller set off. 1. The drum cannot be started or drum rotation is stopped because tape transport load is too high. 1
...error is defined as [E06], and the mechanism mode is shifted to STOP with the pinch roller set off. However, no CAPSTAN EMG is detected in the STILL/FF/REW mode. 1. The CAPSTAN FG signal is not ...
through it. Cleaning may still be the problem. Try running the cleaning tape until it automatically stops (about 20 seconds). You may do 3 passes before giving up. If you still have a problem, you are