Question about LG Heating & Cooling
...MINI SPLIT INDOOR UNIT THERE ARE 5 ELECTRICAL TERMINAL JACK SO WANT TO KNOW THAT WHICH IS THE INDOOR AND WHICH IS THE OUTDOOR WIRING POINT COULD YOU HELP ME PLEASE? Power terminal connection (Left to ...
Question about LG Heating & Cooling
mini split unit the cool light flashes 4 time what's wrong Indoor unit faults = CH04 or C4 Fascia LED's - RED = None - GREEN = 4 Flash Contents = Drain Pump / Float Switch Case of Error = Float Switch
Mini split problems Hi, I'm having problems with my Coaire mini split system. It's been freezing up and spraying water, and at times ice cubes, from the indoor unit. This' often accompanied by a loud ...
my mini split only sometimes responds to the remote indoor pcb in the indoor unit faulty and the responder.
Question about AMVENT Heating & Cooling
WHAT IS REFRIGERANT SUCTION PRESSURE OF MY 1 TON SPLIT AC? R22= 70-80psig R410a=120-130psig Depending on many variables such as blower speed, coils clean, indoor/outdoor temps.
what is a code c1 on a samsung mini split? unit shows this code then shuts down completely. Error code = C1 or CH1 Fault = Indoor temperature sensor open or closed circuit.
Question about Continental Heating & Cooling
...mini split system had an E2 code...replaced indoor pipe sensor...indoor unit works but outside unit does not...no other error codes, just motor not working outside Check the outdoor unit to ensure ...
...fan speed is low on sanyo mini split ks1271 how do I find out whether it is the fan or the fan or the relay on the control board? If there's power to the fan coming from the relay, it's the fan
Question about Fujitsu Heating & Cooling
...mini split hp? Other 2 indoor unit fine Icing is caused by one of two things. 1. The air coming in is too much and has a lot of water vapor in it. 2. The evaporator is too cold. This could be because ...
Question about Panasonic Heating & Cooling
...mini split air conditioner css9nkua. what does run code h99 mean? H99: Indoor heat exchanger anti-freezing protection Causes: - Insufficient refrigerant; - Air filter dirty; - Clogged cross flow
1 questions posted
Usually answered in minutes!
132 Questions
35 Questions
18 Questions
13 Questions
8 Questions