Coleman Propane Forced Air Heater w/Electronic Ignition (50,000-80,000 BTU) "replacement blower fan motor" Questions

Ad

Question about Heating & Cooling

1 Answer

Blower fan not working The blower fan has stopped working. The fan motor was replaced last year. The heat elements appear to be getting hot, and the compressor and compressor fan work. But no air is ...

Ad

Question about Goodman Heating & Cooling

1 Answer

blower motor wiring at the harness and at the control board if connected. You can cut them if you have exact replacement motor and wire nuts. Slide the housing out, turning it on the side that exposes

Ad

...blower motor capacitor and or fan motor, kinked ducting if used can also cause a high limit event. In some cases the limit control and or fan control may need replaced, if it using a circuit board ...

Question about Heating & Cooling

1 Answer

...blower does not kickon,on manual the motor will kickin but I have to spin motor by hand, Sound like its the capicator you didn,t change! Match this up off the side plate of the motor.The capicator is ...

Question about Rinnai Heating & Cooling

1 Answer

...fan, because openings in this type of blower often become clogged with dirt. To clean blower, remove panel that covers filter to gain access to blower or panel on front of furnace. This panel may be ...

Question about Goodman Heating & Cooling

1 Answer

...REPLACE BLOWER MOTOR if its spinning free until motor is energized motor may have bad armature or brushes. If you energize blower and manually give fan motor a spin will it start if so replace

Question about Goodman Heating & Cooling

1 Answer

blower fan not working Hello, I'm having issues with my blower fan for this unit. Furnace fires up to the point of heating the heat exchanger to temp- the AC unit runs until I turn the system off ...

Question about Honeywell Heating & Cooling

2 Answers

...fan are kicking on no problem the blower inside does not kick on when a/c does. I have a whirlpool ndgk100dg01. I think it's a relay, but have no idea where it is? could be a relay possible fan motor ...

Question about Heating & Cooling

1 Answer

...blower fan will not start, but if i spin it manually it will fire up just fine, is this the fan motor or something else? This should be a direct drive blower motor. On a direct drive motor there is a ...

Question about Goodman Heating & Cooling

1 Answer

blower fan came off the motor shaft. I took out the blower and replaced the motor. but can not find my wiring diagram for a gms9/gcs9. THE BLOWER MOTOR HAS 6-WIRES ....2--CAPICATOR (BROWN- BROWN WHITE

Not finding what you are looking for?
Heating & Cooling Logo

373 questions posted

Ask a Question

Usually answered in minutes!

Top Coleman Heating & Cooling Experts

Paul Carew

Level 3 Expert

3808 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Ronny Bennett Sr.
Ronny Bennett Sr.

Level 3 Expert

6988 Answers

Are you a Coleman Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions