Precor 933 Premium Series Treadmill "error 32" Questions

Ad

Question about Precor Exercise & Fitness

1 Answer

error 32 Turn on treadmill, 10 seconds later error 32 scrolls across screen DescriptionErrors 30 through 33 all indicate the loss of communications or erratic communications betweenthe microprocessors

Ad

Question about Precor Exercise & Fitness

1 Answer

...error 32...what do i do to make them work. Precor Error 30, 31, 32 and 33, Communications Error Probable Cause 1. Bad interconnect cable between upper PCA and lower PCA. 2. Interconnect cable is ...

Ad

Question about Precor Exercise & Fitness

1 Answer

...Error 30, 31, 32 and 33, Communications Error Probable Cause 1. Bad interconnect cable between upper PCA and lower PCA. 2. Interconnect cable is mistakenly plugged into the CSAFE connector at the ...

Question about Precor Exercise & Fitness

1 Answer

...Error 30, 31, 32 and 33, Communications Error Probable Cause 1. Bad interconnect cable between upper PCA and lower PCA. 2. Interconnect cable is mistakenly plugged into the CSAFE connector at the ...

Question about Precor Exercise & Fitness

1 Answer

...Error 30, 31, 32 and 33, Communications Error Probable Cause 1. Bad interconnect cable between upper PCA and lower PCA. 2. Interconnect cable is mistakenly plugged into the CSAFE connector at the ...

Question about Precor Exercise & Fitness

1 Answer

...Error 30, 31, 32 and 33, Communications Error Probable Cause 1. Bad interconnect cable between upper PCA and lower PCA. 2. Interconnect cable is mistakenly plugged into the CSAFE connector at the ...

...Error 30, 31, 32 and 33, Communications Error Probable Cause 1. Bad interconnect cable between upper PCA and lower PCA. 2. Interconnect cable is mistakenly plugged into the CSAFE connector at the ...

Question about Precor Exercise & Fitness

1 Answer

...Error 32 is defined as lowerPCA not receiving from upper PCA. Error 33 is defined as faulty data received from upper PCAPossible Causes1. An upper PCA to lower PCA interconnect cable is bad.2. The ...

Error 32 is defined as lower PCA not receiving from upper PCA. Error 33 is defined as faulty data received from upper PCA Possible Causes 1. An upper PCA to lower PCA interconnect cable is bad. 2. The

Question about PaceMaster Exercise & Fitness

1 Answer

...Error 32 is defined as lowerPCA not receiving from upper PCA. Error 33 is defined as faulty data received from upper PCAPossible Causes1. An upper PCA to lower PCA interconnect cable is bad.2. The ...

Not finding what you are looking for?
Precor 933 Premium Series Treadmill Logo

26 questions posted

Ask a Question

Usually answered in minutes!

Top Precor Exercise & Fitness Experts

Sportsmith LLC
Sportsmith LLC

Level 3 Expert

920 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Grand Canyon Tech
Grand Canyon Tech

Level 3 Expert

3867 Answers

Are you a Precor Exercise and Fitnes Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...