Goodman CKL24AR24 Air Conditioner "wire reversing capacitor start motor" Questions

Ad

Question about Ruud Heating & Cooling

1 Answer

...the fan like that. If anyone worked on the unit before it started running like that you should make sure the capacitor is connected to the start wire and not the run wire. Let me know what you

Ad

Question about Goodman Heating & Cooling

4 Answers

...reversing the Fan Wires on the new capacitor, the fan spun clockwise and the air was blowing out of the unit.  On the new capacitor the Light Colored Yellow Fan wire was this time connected to ...

Ad

Question about Heating & Cooling

1 Answer

...going to be the best advice I can give you. If they can prove that a capacitor caused the motor to permanently run backwards..... I want to know! Hope this helps and good luck with your

Question about Coleman Heating & Cooling

1 Answer

...reversing the leads with each test). This will verify the capacitors condition. Good Capacitor If the capacitor is good, the indicator will move from infinity (the left side), towards zero ohms and ...

Question about Maytag Heating & Cooling

3 Answers

...start when turned on. The motor hums but will not turn. I lubricated the bearing so it will turn very easy. Is there a starting capacitor for that motor. Give me some ideas to how we can make the fan ...

Question about Goodman Heating & Cooling

3 Answers

reversing the direction should be orange and yellow or purple and yellow and will be shorter than the rest. Hope this helps. Let me know what you find. Mine is doing the same thing. I got this Goodman

Question about Goodman Heating & Cooling

6 Answers

wire and the fan power lead is reversed. this has happened to me several times because i wasn't paying attention. If original fan motor, not repaced with universal, or wrong motor then - Always remove

...capacitor to an already bad start dual cap. Case in point: I come across a condenser where the fan motor is running (in the right direction, up) but the compressor is not. I put a hard start cap on ...

Question about Carrier Heating & Cooling

1 Answer

...capacitor is connected to the start lead, not the run lead(s). Also some fans come with some wires you can switch to reverse the direction. If your motor has them there will be 4 and the label on the ...

...wire of blowing fan.Check how many leads make sure to make sketch where it was connected from low,medium, and high there is coded color on it,discannect from the terminal, using clamp ammeter set to ...

Not finding what you are looking for?
Goodman CKL24AR24 Air Conditioner Logo

154 questions posted

Ask a Question

Usually answered in minutes!

Top Goodman Heating & Cooling Experts

Paul Carew

Level 3 Expert

3808 Answers

Mike Cairns
Mike Cairns

Level 3 Expert

3054 Answers

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

Are you a Goodman Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions