Bosch AquaStar Indoor Natural Gas Tankless Water Heater with Vent Hood #125 "125 water valve" Questions

Ad

Question about Bosch Water Heaters

1 Answer

125 no water preasure All of my faucets and shower heads have very low water pressure. How do I backwash my system? Clean water filter yearly or monthly. Page 16 example manual.http://waterheatertimer

Ad

Question about Bosch Water Heaters

1 Answer

...service the water valve every 1-2 years. It is the most common cause of the 125 series heater not working. There is also an inlet filter screen on the water valve that needs to be cleaned or

Ad

...125 Tankless Water Heater - Water not hot enough I've had a Bosch 125 Tankless water for four years or so. Can't remember the exact model, but it has a standing pilot light. It has been working ...

...125 pilot went out. No problem, I relit it. It has gone out several times since then. But when I relight it, it often turns the burner on as if the faucet is running. AF ter a few minutes it screams ...

water is only getting warm with aquastar 125 bng model. It just started getting warm and not hot. What could be the problem? Insufficient gas presure. Check gas presure exiting regulator exrternal of ...

...water heater came with 125 psi. Rating shows in small print on end of TP. New TP valves sold at local hardware. Let tank cool before installing new one.7) Higher temperature and high pressure can ...

Question about General Electric Water Heaters

1 Answer

...water-heater-temperature.html 3) If steps above don't fix problem, replace TP valve >> TP valves have 125 or 150 degrees rating >>> older tank shouldn't be running above 125 because ...

Question about Powerstar Water Heaters

1 Answer

125. The light comes on on the panel, but water is usually ice cold. Have tried adjusting the thermostat but same results. Open to any suggestions on this matter. Thanks Any suggestion could include a

Question about Bosch Water Heaters

1 Answer

125 BNG,will not shut down automatically when water turned off. The water valve may be dirty and sticking, prohibiting it from fully closing the gas valve. This part needs to be periodically serviced

heating water even though there is no pressure, ie hot water is not turn on. Service the water valve. The pin is not returning to the off position. The water valve should be serviced every year or two

Not finding what you are looking for?
Bosch AquaStar Indoor Natural Gas Tankless Water Heater with Vent Hood #125 Logo

121 questions posted

Ask a Question

Usually answered in minutes!

Top Bosch Water Heaters Experts

Colin Stickland
Colin Stickland

Level 3 Expert

22516 Answers

john h

Level 3 Expert

28886 Answers

David Shaub

Level 3 Expert

2994 Answers

Are you a Bosch Water Heater Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides