Fan blower motor not working - 1996 Mercedes-Benz C-Class

2 Answers

Anonymous

Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Master:

An expert who has achieved Level 3.

  • Master 378 Answers
  • Posted on Jan 16, 2011
Anonymous
Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Master:

An expert who has achieved Level 3.

Joined: Jan 13, 2011
Answers
378
Questions
1
Helped
102451
Points
1182

Check the fuses and relays goodluck

Testimonial: "thank you!!"

Anonymous

Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

  • Contributor 1 Answer
  • Posted on Nov 21, 2011
Anonymous
Contributor
Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Joined: Nov 21, 2011
Answers
1
Questions
0
Helped
431
Points
1

I bought a c230, blower not working, checked fuses, 1 blown, replaced it, still not working, decided to remove the blower under the glove compartment, found the floor wet, as i removed the blower cover i have found water and leaves under the blower, removed the blower, tested it, found out that it was a gonner, bought a second hand one works fine, now, where did the water come from? can anyone help?
[email protected]

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1helpful
2answers

2000 Chevrolet Impala blower motor work from 1-4 but not on 5th speed why?

The blower motor relay is energized when the Blower Motor Control is set to the High position. This removes the blower motor resistors from the circuit and battery voltage is then applied directly from the HVAC BLO fuse (RH IP Accessory Wiring Junction Block) to the blower motor though the relay switch contacts. The blower motor then runs at high speed.

HVAC Blower Controls Circuit Description
The blower motor is a variable speed motor. The motor operates at a higher rate when voltage is increased to the maximum level.
The blower motor resistors reduce the voltage supplied from the A/C FAN fuse (LH IP Accessory Wiring Junction Block) when the blower control is set at low and medium speeds (speeds 1-4). The blower motor relay is energized when the Blower Motor Control is set to the High position. This removes the blower motor resistors from the circuit and battery voltage is then applied directly from the HVAC BLO fuse (RH IP Accessory Wiring Junction Block) to the blower motor though the relay switch contacts. The blower motor then runs at high speed.
0helpful
1answer

1991. Why doesn't A/C fan work?

Check the AC fan relay
Symptoms Of A Defective Blower Motor Relay
The blower motor relay's job is to basically bypass the current that passes thru' blower motor resistor and deliver it directly to the blower motor. With the blower motor getting full battery current, it'll run in HI speed.

The most common symptom you'll see, when the blower motor relay fails in your Chevy S10 (GMC S15), is that the blower motor will not run in HI speed (but will run in LO, M1, and M2 speeds).

In some cases, the blower motor will fail and the blower motor will not run in HI but you'll have all of the other speeds working.


https://easyautodiagnostics.com/gm/2.8L/blower-motor-relay-multimeter-test-1

..
2helpful
2answers

2004 crown vic. only 63K miles on her. AC/heat fan was sporadically working, now its done. AC was nice and cold, working fine. Is the fan a hard replacement if I were to find one at a parts yard?

Try to check the power and ground on the blower fan. If you missing the ground on the blower fan connector than most likely it is the blower fan resistor (controller), it is located under the hood close to back firewall behind left cylinder head.
5helpful
2answers

01 grand.prix ac fan switch only works on high. has a duel temp controller when you turn fan off the only way fan comes back on is to move the temp controller levers

Hi!!
When the Blower Motor Resistor (controls blower speeds) goes bad, the blower motor works only on HIGH SPEED. REPLACE IT.
BLOWER MOTOR RESISTOR Removal & Installation
  • Disconnect negative battery cable.
  • Remove right lower instrument panel insulator panel.
  • Disconnect blower resistor connector located behind right side of dash.
  • Remove blower resistor screws and blower resistor.
To install, reverse removal procedure
Good Luck!! A HELPFUL - 4 THUMBS - rating for this solution would be greatly appreciated. Thank you for using FixYa!!
2helpful
2answers

Heater blower stopped working?

Hello,
You may want to try your fan on all speeds. If it will work on high, you have a bad resistor for the fan motor. ( high speed doesn't go through the resistor ).
If it doesn't work on any speed, I would check the following;
1. Make sure the fuse isn't blown for the fan blower motor.
2. Check, or have checked the wires between the fan control switch and the fan blower motor.
3. Have the fan control switch checked.
4. Have the fan blower motor checked.

I hope this helps you.
0helpful
1answer

My 1988 Ford Tempo's heater fan is not working. I can feel heat at the windshield vents,but the fan wont come on. I have jumped the fan speed switch with a paper clip--and blew a fuse--and checked the...

your circuit is simple--I will paste it below. suspect the blower has shorted and caused the switch to burn up. remove the blower and hotwire it to the battery to see if it works. If not, replace the blower. Then run continuity tests on the swoitch and replace switch if bad. If you have questions, please let me know. Here is procedure for taking blower out:


REMOVAL & INSTALLATION With Air Conditioning

  1. Disconnect the negative battery cable.
  2. Remove the glove compartment door and glove compartment by removing the retaining screws and bolts. Push the sides of the glove box in to free the drawer from dash panel.
  3. Loosen the instrument panel at the lower right hand of the glove compartment opening. This is on it necessary if the panel is in the way of the motor housing.
  4. Remove the retaining screws securing the ducting around the blower motor.
  5. Remove the clip securing the blower motor fan blade to the motor arm. Remove the fan blade from the motor.
  6. Remove the blower motor mounting plate from the evaporator case by unscrewing the retaining screws.
  7. Rotate the motor until the mounting plate clears the edge of the glove compartment opening and remove the motor.
  8. Remove the wire harness from the rear of the motor.
  9. Inspect the fan blade for broken edges or cracks. Replace if needed.

To install:
  1. Connect the wire harness to the rear of the blower motor.
  2. Install the motor into the case and secure with the retaining screws.
  3. Position and fasten the fan blade to the blower motor arm. Secure with the clip.
  4. Secure the blower motor outer housing to the duct assembly with the retaining screws.
  5. Install the instrument panel at the lower right hand side if removed earlier.
  6. Install the glove compartment door and glove compartment.
  7. Connect the negative battery cable.
  8. Run blower motors to make the motor works correctly.
Without Air Conditioning
  1. Disconnect the negative battery cable.
  2. Remove the right ventilator assembly.
  3. Remove the hub clamp spring from the blower wheel hub. Pull the blower wheel from the blower motor shaft.
  4. Remove the blower motor flange attaching screws located inside the blower housing.
  5. Pull the blower motor out from the blower housing (heater case) and disconnect the blower motor wires from the motor.

To install:
  1. Connect the wires to the blower motor and position the motor in the blower housing.
  2. Install the blower motor attaching screws.
  3. Position the blower wheel on the motor shaft and install the hub clamp spring.
  4. Install the air inlet duct assembly and the right ventilator assembly.
  5. Connect negative battery cab
  6. Check the system for proper operation.

36d4b25.gif
3helpful
2answers

2005 Chevrolet Silverado - Fan not coming on. When I turn the heater/ac blower fan on, fan does not work. Prior to completely going out, fan would quit working intermittently. Is this a fuse problem? ...

Chk for power at the blower motor electrical connector. If no voltage, check the blower motor resistor, its within the blower motor vent (this controls power to the blower motor). Also, in theses vehicles water may have damaged the blower motor itself. Inspect the blower motor for proper function.
1helpful
1answer

Blower motor doesn't work and has no power to it

Check the blower multispeed control resistor pack is not faulty.
The resistor pack is usually located in the air ducting, in the blower fan airflow.
Basically, +12v power is supplied (via fuse) to the fan speed control switch, which then passes via the selected speed control resistor, to the fan motor. Often a interface relay is used to switch the blower motor high current.
4helpful
2answers

Blower fan not working correctly

It is the blower motor resistor and is located under the glovebox behind the blower motor.
Not finding what you are looking for?

441 views

Ask a Question

Usually answered in minutes!

Top Mercedes-Benz Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

xxxxxx xxx

Level 3 Expert

5117 Answers

Arnie Burke
Arnie Burke

Level 3 Expert

7339 Answers

Are you a Mercedes-Benz Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...